Cadence Type
Sets the type of ringing produced when in PLAR mode. May be set
to
North American
,
European
or
Steady
.
Note:
This field is active only if PLAR is selected in the Signalling
Type field (see Signalling Setup window) and the unit's Micro code
is version 2.5 or later.
Ringing Duration
Sets the ringing duration when in PLAR mode. May be set to
10
sec
,
20 sec
,
60 sec
and
Indefinite
.
Note:
This field is active only if PLAR is selected in the Signalling
Type field (see Signalling Setup window) and the unit's Micro code
is version 2.5 or later.
Note:
In the Loop Start (LS) and Ground Start (GS) signaling
modes the ringing duration is not limited.
Signalling Monitor
XMT
Signalling
Shows current signaling status sent towards the far-end unit.
Note:
When an Invalid signaling condition (i.e. combination of the
two signaling bits) is selected in the Transmit Signalling field (see
Test Setup frame), the unit will send the selected combination even
though it does not apply to any valid signaling condition for the
Signalling Type chosen.
Receive
Signalling
Shows current signaling status received from the far-end unit
(unless overridden by the locally forced RCV Signalling test
condition in which case the forced condition is displayed).
Unit Monitor
Unit
Status
Displays the current status of the unit. The possible readings are:
Temperature
(unit temperature exceeds 93ºC) and
OK
.
Temperature
Displays the current temperature of the unit in ºC. An alarm is raised in
the Unit Status field if this reading exceeds 93ºC.