![GE JB970 series Owner'S Manual And Installation Instructions Download Page 35](http://html.mh-extra.com/html/ge/jb970-series/jb970-series_owners-manual-and-installation-instructions_130904035.webp)
Safety Instructions
Operating Instructions
Care and Cleaning
Installation Instructions
Troubleshooting T
ips
Customer Service
35
Read these instructions completely and carefully.
4-Wire Power Cord Installation
WARNING:
The neutral wire of the
supply circuit is connected to the neutral
terminal located in the center of the connector
block. The power leads must be connected to
the outside (brass colored) terminals. The 4th
grounding lead must be connected to the frame
of the range with the grounding plate and
grounding screw.
Remove the 3 screws from the connector
block.
Remove the grounding screw and strap from
the connector block middle location and the
screw connection to the frame of the range.
Insert screws through each power cord
terminal ring and into connector block until
screw engages nut. Be certain that the center
wire is connected to the center screw of the
connector block. Tighten screws securely.
Attach ground wire to the frame of the
range.
3-Wire Power Cord Installation
WARNING:
The neutral or ground
wire of the power cord must be connected to
the neutral terminal located in the center of the
connector block. The power leads must be
connected to the outside (brass colored)
terminals.
Remove the 3 wire terminal screws from the
connector block. Insert screws through each
power cord terminal ring and into the connector
block until the screws engage the nuts. Be certain
that the center wire is connected to the center
screw of the connector block. Tighten screws
securely.
Do NOT remove ground strap connection.
Neutral terminal
Ground strap
Power cord
Connector block
Before
Neutral terminal
Ground strap
(grounding to range)
Neutral terminal
After
Grounding plate
Grounding to range