background image

 

 

 

3-10 

 6" QuickPanel* ViewBasic, Monochrome, Round Bezel –  September 2010  

GFK-2327B  

 

 

 

3

 

   

 

 

Keyboard 

The QuickPanel View can be configured to use a software emulation keyboard 
as an operator data input device.  

Soft Input Panel  

The Soft Input Panel (SIP) is a touch screen version of a standard keyboard, 
which can be used in place of a standard hardware keyboard.  

An icon in the system tray lets you view or hide the SIP.  

Soft Input Panel icon

 

 

To show/hide the Soft Input Panel  

On the system tray of the task bar, double-tap the icon. The Soft Input Panel 
appears/disappears.  

Note: 

When the SIP is visible, it can be dragged around the screen by its 
title bar to reveal different parts of the screen that would be 
obstructed from view by the SIP.  

Summary of Contents for IC754VSB06MTD

Page 1: ...GE Intelligent Platforms Operator Interface Products 6 QuickPanel View Basic Monochrome Round Bezel IC754VSB06MTD IC754VBB06MTD Hardware User s Guide GFK 2327B September 2010...

Page 2: ...the information contained herein does not purport to cover all details or variations in hardware or software nor to provide for every possible contingency in connection with installation operation or...

Page 3: ...Support Email 7H8Hsupport ip ge com Customer Care Email 9H10Hcustomercare ip ge com Primary language of support English Europe the Middle East and Africa Online Technical Support 11H12Hwww ge ip com s...

Page 4: ......

Page 5: ...or other software or hardware which pools or aggregates connections Note that the QuickPanel View does not provide any server functionality utilizing Remote Desktop Protocol RDP to remotely connected...

Page 6: ...t under FCC rules Industry Canada requires the following note to be published This Class A digital apparatus complies with Canadian ICES 003 The following statements are required to appear for Class I...

Page 7: ...ed Operation 3 1 Touch Screen Display 3 2 Serial Communication Port 3 15 Ethernet 3 23 DIP Switches 3 28 Memory 3 30 Other Subsystems 3 33 Specifications A 1 Physical A 1 DC Power A 2 Display A 3 Fron...

Page 8: ......

Page 9: ...elopers alike The availability of third party application software makes this operating system even more attractive The 6 QuickPanel View is an all in one microcomputer designed for maximum flexibilit...

Page 10: ...ower supply via the supplied quick connect plug Depending on your application you may also want to connect and configure communications ports as described in chapter 3 Optional Ethernet Connection Pow...

Page 11: ...and conductor specifications 2 Insert the plug into the power supply socket and securely tighten the attaching screws Note The torque range for the attaching screws is 4 6 inch lbs Unit Runtime Setup...

Page 12: ...ear on the display is the splash screen 2 To skip running any programs included in the StartUp folder tap Don t run StartUp programs The splash screen disappears automatically after about 5 seconds Th...

Page 13: ...There are no specific dangers associated with a power failure or other unplanned shutdown of the QuickPanel View In general programs are retained in FLASH memory and user data can be retained in batte...

Page 14: ...and 12 qualification the unit must be mounted in a comparably NEMA rated IP56 equivalent panel or enclosure For compliance to ATEX agency qualification the unit must be mounted in an IP66 panel or enc...

Page 15: ...ion must be carefully considered to avoid exceeding the operational temperature limits These considerations could include shading for the QuickPanel and its cabinet with awnings or other solar opaque...

Page 16: ...3 Firmly tighten the screws Note The torque range for the mounting bracket screws is 2 6 4 4 inch lbs 0 3 0 5 Nm The mounting clamps hold the unit in place by tension No drilling is required Do not d...

Page 17: ...2H2 Block Diagram 2 3H4 QuickPanel View Software 2 4H5 Windows CE NET 2 5H5 Working with Windows CE 2 6H6 To place a program in the Start menu 2 7H6 Backup 2 8H7 To run the Backup program 2 9H7 Reboo...

Page 18: ...ut of the QuickPanel View and the locations of ports and connections Caution Remove power from the QuickPanel View before opening the back Working on a live unit may result in damage to equipment and...

Page 19: ...GFK 2327B Chapter 2 Overview 2 3 2 Physical Layout of QuickPanel View...

Page 20: ...ck Diagram The 6 QuickPanel View is based on the XScale microprocessor and employs large scale integration to provide high performance with a small footprint The following block diagram illustrates th...

Page 21: ...earning curve for those having experience with Windows 95 98 NT 2000 ME XP From the software developer s perspective the CE environment is a subset of the WIN32 application programming interface simpl...

Page 22: ...ouch screen calibration SPACEBAR Equivalent to single tap ENTER Equivalent to double tap In a dialog box equivalent to OK TAB In a dialog box select next control SHIFT TAB In a dialog box select previ...

Page 23: ...tores the Windows CE registry including any control panel settings in Flash memory It stores any changes or additions made to the Windows subtree of the file system in the user block of FLASH memory R...

Page 24: ...Windows CE operating system then restarts the QuickPanel View This ensures all open files are closed properly To reboot the system 1 To save changes to system configurations run Backup see page 2 19H7...

Page 25: ...Information window which provides information such as hardware version and serial number CPU type and specifications etc This information can be especially useful if you are contacting Technical Supp...

Page 26: ...uring an ActiveSync session enabling the download of third party Pocket PC 2003 software To use Emulate PPC during an ActiveSync session 1 Start Windows Explorer double tap Windows then double tap Emu...

Page 27: ...y is an executable EXE file included in the 6 QuickPanel View operating system The HTTP utility currently supports two file transfer commands COPY and DELETE Note In order to function the HTTP File Tr...

Page 28: ...webfiles MyFileBACKUP txt Copies a file called MyFile txt on drive C of the local computer to the webfiles folder under the web server at MyServer Note that you can rename a file as you copy it HTTPUT...

Page 29: ...nts for the serial port cabling and working with the serial COM port Ethernet 3 3H23 Setting an IP address Setting up access to a Windows network Accessing a remote resource on a Windows network DIP S...

Page 30: ...panel monochrome display The monochrome display is backlit measures 5 7 diagonally and uses passive FSTN technology The resolution of the monochrome display is 320 x 240 pixels and 256 shades of gray...

Page 31: ...display contrast 1 In the Control Panel double tap Display and choose the Contrast tab The Contrast dialog box appears 2 Drag the Brightness slider between Lowest and Highest 3 Tap OK to exit the con...

Page 32: ...ect backlight auto turn off 1 In the Control Panel double tap Display and choose the Backlight tab The Backlight dialog box appears 2 Select Auto turn off backlight while on external power 3 Tap OK to...

Page 33: ...QuickPanel View is properly calibrated this translates into a grid of touch cells on the face of the display A blunt stylus should always be used during calibration for greatest accuracy During norma...

Page 34: ...ckPanel ViewBasic Monochrome Round Bezel September 2010 GFK 2327B 3 To calibrate the touch screen 1 In the Control Panel double tap Stylus The Stylus Properties dialog box appears 2 Choose the Calibra...

Page 35: ...n 3 7 3 3 Tap the Recalibrate button A cross hair target is displayed Note For greatest accuracy it is recommended that you use a blunt stylus when calibrating the touch screen 4 Follow the directions...

Page 36: ...ewBasic Monochrome Round Bezel September 2010 GFK 2327B 3 5 Tap the screen to preserve the new setting or wait out the time limit to revert to previous settings 6 To save the settings run the Backup u...

Page 37: ...s The Stylus Properties dialog box appears 2 Choose the Double Tap tab 3 Double tap the grid to enter a setting 4 Double tap the test icon to check the setting If the test icon doesn t change when you...

Page 38: ...on of a standard keyboard which can be used in place of a standard hardware keyboard An icon in the system tray lets you view or hide the SIP Soft Input Panel icon To show hide the Soft Input Panel On...

Page 39: ...plications to change the input panel state check box 3 Select or clear the Show Input Panel in system tray check box 4 Tap OK 5 To save the settings run the Backup utility See page 2 7 The Soft Input...

Page 40: ...case after another key is pressed Pressing the CAP key causes the Soft Input Panel to remain in upper case mode The CTRL and ALT keys behave the same as the SHIFT key Small Key Upper Case Large Key c...

Page 41: ...Key Upper Case To change key configurations 1 In the Control Panel double tap Input Panel The Input Panel Properties dialog box appears 2 From the Current input method list choose CE Keyboard 3 Tap O...

Page 42: ...to finish 6 To save the settings run the Backup utility See page 2 7 To reset the SIP Location If you accidentally drop the SIP off screen and can t drag it back on screen complete the following steps...

Page 43: ...utility A connection can be configured to reside on a network supporting a TCP IP protocol A DB25S female connector mounted on the bottom of the enclosure provides standard signals as described in the...

Page 44: ...l the port appropriately in the EIA 485 two wire mode In all QuickPanel View models the RTS Request to Send control signal is brought out on the COM1 connector but is also connected to the driver enab...

Page 45: ...maximum number of nodes or devices that can be connected to a TIA EIA 422 or 485 network Instead the standards limit the number of electrical connections by specifying that a maximum of 32 unit loads...

Page 46: ...k should not be tied together The cable shield and signal ground should be connected together at only one device closest to the earth ground connection The signal and frame grounds of the QuickPanel V...

Page 47: ...t menu tap Settings and then Network and Dial up Connections The Connection window appears 2 Double tap Make New Connection The Make New Connection window appears 3 Type a name for the new connection...

Page 48: ...ed it is available in the device list You can configure your device or TCP IP Settings at this time if you wish 7 Tap Finish for direct connection Device dialog box or Next for dial up Modem dialog bo...

Page 49: ...erties dialog box appears 2 In the Port Settings tab choose settings for all connection preferences 3 If the connection is for terminal emulation select or clear the terminal related check boxes You c...

Page 50: ...fault TCP IP settings 1 Obtain correct TCP IP settings from your network administrator 2 From the Device Modem PPPoE Connection or VPN Connection dialog box tap TCP IP Settings The TCP IP Settings dia...

Page 51: ...ielded twisted pair UTP CAT 5 to the unit via the RJ45 connector on the bottom of the enclosure LED indicators on the port indicate channel status Access to the port is possible either by Windows CE n...

Page 52: ...be assigned Contact your network administrator to ensure correct DHCP server configuration Manual method You uniquely specify the numeric addresses for the QuickPanel View the Subnet Mask and the Def...

Page 53: ...ress via DHCP automatic Specify an IP address manual 4 Enter the IP Address Subnet Mask and Default Gateway numbers obtained from your network administrator manual method only 5 Tap OK 6 To save the s...

Page 54: ...k 1 In the Control Panel double tap System The System Properties dialog box appears 2 On the Device Name tab in the Device name box type a unique name for your QuickPanel View In the Device descriptio...

Page 55: ...The Explorer window appears 2 Type in the Address box or choose from a list the path to a remote resource For example MyRemoteComputer MyFolder specifies the folder named MyFolder on a computer with...

Page 56: ...o OFF by default in the factory DIP switch 2 is the Force Startup switch Turning this switch on forces the startup applications to run when the operating system is started When the switch is set to OF...

Page 57: ...C power supply before opening the QuickPanel View Working on a live unit may result in damage to equipment and injury to personnel Always use anti static precautions i e grounded wrist strap when acce...

Page 58: ...and is not directly accessible from Windows CE Explorer The operating system and all user application programs are transferred from Flash to DRAM for execution Any user additions to the Windows folde...

Page 59: ...etained through a power cycle The split between program memory and storage memory may be adjusted as necessary to make more room for one or the other depending on your specific application needs For e...

Page 60: ...used by each area is displayed numerically The blue bar indicates the current amount of unallocated DRAM and determines the boundaries within which the slider can move 3 Tap OK to apply the new settin...

Page 61: ...ower Properties control panel displays the status of the backup battery The Battery Very Low Or Missing icon appears in the taskbar when the battery is either missing or very low To access the Power P...

Page 62: ...stalling or removing the battery accessed via the rear panel as shown in the following illustration Caution Remove power from the QuickPanel View before opening the back Working on a live unit may res...

Page 63: ...ng the arrow on the carrier indicating the direction of removal To install a new battery 1 Disconnect AC power from the DC supply 2 Open the rear access panel Note Battery must be installed with posit...

Page 64: ...y backup is available Daylight saving time is enabled by a check box within the dialog box The time can be displayed in the system tray on the task bar To set the real time clock 1 In the Control Pane...

Page 65: ...ours minutes and seconds 8 Tap OK to finish 9 To save the settings run the Backup utility See page 2 7 To display the time on the taskbar 1 From the Start menu choose Settings and then Taskbar and Sta...

Page 66: ......

Page 67: ...l service and safety Physical Height 4 86 in 126 mm Width 6 14 in 156 mm Enclosure dimensions actual see Panel Cutout in chapter 3 for cutout dimensions Depth 2 026 in 51 5 mm Height 6 17 in 156 7 mm...

Page 68: ...total inrush current requirements In this case supply should be rated at 10x the nominal startup current Otherwise an interposing relay or switch must be used between the DC supply and the QuickPanel...

Page 69: ...laceable Luminance 100 NITS Front Panel Bezel Material Valox 3706 For material specifications visit www gepolymerland com Membrane Material Lexan HP60 For material specifications visit geplastics com...

Page 70: ...Memory Flash 16 MB DRAM 16 MB ROM 512 KB Boot loader Communication Ports IEEE 802 3 10 BaseT 100 Base TX RJ45 connectors Two status LEDs Ethernet Maximum cable length 30m Serial COM1 EIA232C EIA485 DP...

Page 71: ...0068 2 6 10 57Hz 0 012 peak to peak displacement Operational Vibration 57 500Hz 1 0g acceleration IEC 60068 2 27 Operational Shock 15g 11ms sine wave Rated temperature limits refer to the ambient air...

Page 72: ...ter s Laboratories to Type 4X Explosive Atmospheres Directive European Safety for Hazardous Locations Equipment Group II Category 3 ATEX when mounted in an IP66 enclosure Certification in accordance w...

Page 73: ...These errors can cause higher system overhead leading to delayed response to touch inputs Ensure that flash drives internal or external are operating without error If the flash drives are highly fragm...

Page 74: ......

Page 75: ...Dimensions bezel A 1 cutout 1 6 module A 1 DIP Switches 3 28 Display operation 3 2 specifications A 3 DRAM memory 3 31 E Emulate PPC 2 10 Environmental requirements A 5 Ethernet port operation 3 23 F...

Page 76: ...Remote resource accessing 3 27 Runtime setup 1 3 S Shutdown 1 5 Software 2 5 Specifications A 1 Startup 1 4 configuring 3 29 System Information 2 9 T Technical Support See page iii Touch response dia...

Reviews: