DIAGNOSTIC STATUS CODES
SX TRANSISTOR CONTROL
Page
42
October 2002
TRACTION
STATUS CODE
DESCRIPTION OF STATUS
CAUSE OF STATUS INDICATION
-95
Pump motor brush wear indicator has
detected worn brush.
This status code will be displayed when the voltage at
the respective terminal of the TMM or Pump Logic
Card is at battery volts.
MEMORY RE ALL
C
YES
CORRECTIVE ACTIONS
TROUBLE-SHOOTING DIAGRAM
Circuits valid
for
Pump
Motor
Brush Wear
Indicator
SYMPTOM
Status code flashes “on and off”.
POSSIBLE CAUSE
Pump motor brushes are worn.
Plug P8 (pump) is shorted to positive.
Defective input switch (shorted).
Defective TMM module.
Defective pump controller.
SC95
POS
P8
USER SW
WHEN SR Series PUMP
CONTROL IS USED
TRACTION
STATUS CODE
DESCRIPTION OF STATUS
CAUSE OF STATUS INDICATION
-95
Pump motor brush wear indicator has
detected worn brush.
This status code will be displayed when the voltage at
the respective terminal of the TMM or Pump Logic
Card is at battery volts.
MEMORY RE ALL
C
YES
CORRECTIVE ACTIONS
TROUBLE-SHOOTING DIAGRAM
Circuits valid
for
Pump
Motor
Brush Wear
Indicator
SYMPTOM
Status code flashes “on and off”.
POSSIBLE CAUSE
Pump motor brushes are worn.
Plug P9 (pump) is shorted to positive.
Defective input switch (shorted).
Defective TMM module.
Defective pump controller.
SC95A
POS
P9
USER SW
WHEN SR Series PUMP
CONTROL IS USED