background image

6

Installation Instructions

GAS REQUIREMENTS

DRYER GAS SUPPLY CONNECTION

GAS SUPPLY

•  A 1/8” National Pipe Taper thread plugged 

tapping, accessible for test gauge connection, 
must be installed immediately upstream of the 
gas supply connection to the dryer. Contact your 
local gas utility should you have questions on the 
installation of the plugged tapping.

•  Supply line is to be 1/2” rigid pipe and equipped 

with an accessible shutoff within 6 feet of, and in 
the same room with, the dryer.

•  Use pipe thread compound appropriate for 

natural or LP gas or use PTFE tape.

•  Connect flexible metal connector to dryer and 

gas supply.

ADJUSTING FOR ELEVATION

•  Gas clothes dryers input ratings are based on 

sea level operation and need not be adjusted 
for operation at or below 2000 ft. elevation. For 
operation at elevations above 2000 ft., input 
ratings should be reduced at a rate of 4 percent 
for each 1000 ft. above sea level. 

• Installation must conform to local codes and 

ordinances or, in their absence, the NATIONAL 
FUEL GAS CODE, ANSI Z223.

You must use with this dryer a flexible metal connector 

(listed connector ANSI Z21.24 / CSA 6.10). The length 

of the connect shall not exceed 4 feet.

•   Use a new CSA International approved flexible 

gas supply line. Never reuse old flexible 

connectors.

•   Install an individual manual shut-off valve within 

6ft. of the dryer in accordance with the National 

Fuel Gas Code, ANSI Z223.1/NFPA 54.

•   Securely tighten all gas connections.
•   If connected to LP gas, have a qualified 

person make sure gas pressure 

DOES NOT

 

exceed 13” water column.

•   Examples of a qualified person include: 

licensed heating personnel, authorized gas 

company personnel, and authorized service 

personnel.

•   Failure to do so can result in death, 

explosion, or fire.

•  The installation must conform with local codes, 

or in the absence of local codes, with the 

National Fuel Gas Code, ANSI Z223.1/NFPA 54, 

or the Natural Gas and Propane Installation 

Code, CSA B149.1.

FOR USE WITH NATURAL GAS ONLY

Dryer as produced by manufacturer is to be used 

only with a natural gas supply. A manufacturer-

supplied conversion kit is required to convert this 

dryer for propane gas supply. Use propane gas 

conversion kit WE25X217. Conversion must be 

made by properly trained and qualified personnel 

in accordance with local codes and ordinances.

- Fire Hazard

WARNING

-  Explosion Hazard

WARNING

CONNECTING A GAS DRYER (cont.)

1-7/8"

3-1/8"

3/8" NPT MALE THREAD GAS SUPPLY

NOTE: Add to vertical dimension

the distance between cabinet

bottom to floor.

Summary of Contents for GTX52GASPWB

Page 1: ...ceed 4 feet FOR GAS DRYERS ONLY BEFORE YOU BEGIN Read these instructions completely and carefully IMPORTANT Save these instructions for local electrical inspector s use IMPORTANT Observe all governing...

Page 2: ...at GEApplianceparts com 24 hours a day or by phone at 877 959 8688 during normal business hours STEAM WATER HOSES for steam dryer models only ACCESSORIES Order on line at GEApplianceparts com 24 hours...

Page 3: ...he floor for a garage installation Failure to do so can result in death explosion or fire The dryer MUST be vented to the outdoors Minimum clearance between dryer cabinet and adjacent walls or other s...

Page 4: ...n at the same time NOTE Use new inlet hoses never use old hoses 1 Turn the cold water faucet off Remove the washer inlet hose from the washer fill valve connector cold 2 Ensure the rubber flat washer...

Page 5: ...discard old flexible gas connector and ducting material Shut off Valve MATERIALS YOU WILL NEED 4 dia metal elbow Pipe compound or PTFE tape Flexible gas line connector Duct clamps 2 or Spring clamps...

Page 6: ...nect shall not exceed 4 feet Use a new CSA International approved flexible gas supply line Never reuse old flexible connectors Install an individual manual shut off valve within 6ft of the dryer in ac...

Page 7: ...ER TO THE GAS SUPPLY cont Open the gas shut off valve F Apply pipe compound or PTFE tape to all male threads Shut Off Valve Plugged Tapping CONNECTING THE DRYER TO THE GAS SUPPLY Install a female 3 8...

Page 8: ...wn grounding will reduce the risk of electric shock by providing a path of least resistance for electric current This dryer uses a cord having an equipment grounding conductor and a grounding plug The...

Page 9: ...r power cord kit not provided with dryer UL rated 120 240V 30A with 3 or 4 prongs Identify the plug type as per the house receptacle before purchasing line cord Flat blade screwdriver Phillips screwdr...

Page 10: ...akdown grounding will reduce the risk of electric shock by providing a path of least resistance for electric current This dryer uses a cord having an equipment grounding conductor and a grounding plug...

Page 11: ...MINAL BLOCK 1 Turn off the circuit breaker s 30 amp or remove the dryer s circuit fuse at the electrical box 2 Be sure dryer cord is unplugged from wall receptacle 3 Remove power cord cover located at...

Page 12: ...uct In Canada and the United States only transition ducts that comply with UL 2158A STANDARD FOR CLOTHES DRYER TRANSITION DUCT shall be used Avoid resting the duct on sharp objects For best drying per...

Page 13: ...45 elbows will be treated like one 90 elbow For the side exhaust installations add one 90 elbow to the chart For every additional 90 elbow reduce the allowable vent system length by 10 feet When calcu...

Page 14: ...rflow and should require little or no maintenance to prevent clogging Wall caps must be installed at least 12 above ground level or any other obstruction with the opening pointed down SEPARATION OF TU...

Page 15: ...e Use the screw saved previously to secure the duct in place through the tab on the appliance base ADDING ELBOW AND DUCT FOR EXHAUST TO RIGHT ELECTRIC MODELS ONLY OR LEFT SIDE OF CABINET Preassemble 4...

Page 16: ...m up before pressing Start Otherwise the display will not come on The dryer is now ready for use 3 Connect standard metal elbows and ducts to complete the exhaust system Cover back opening with the pl...

Page 17: ...tipped putty knife Small flat blade screwdriver Before you start Unplug the dryer from its electrical outlet Choose the REVERSING THE DOOR instructions A or B for your model A REVERSING THE DOOR SOLID...

Page 18: ...2 hinges and 8 screws 4 for the hinges and 4 for the outer door A REVERSING THE DOOR SOLID DOOR MODELS cont 8 Mount the door on the 2 upper left side hinge screws installed in step 2 Move the hinge s...

Page 19: ...les 2 on the left and 2 on the right 3 Loosen each top hinge screw on right side Remove the door and place it on a protective flat surface to avoid any damage Plastic Cap 4 Left side of front panel Lo...

Page 20: ...you finish Plug the dryer back into its electrical outlet Door Hang door and tighten screws B REVERSING THE DOOR GLASS PANEL DOOR MODELS cont 6 Remove and swap the 2 plastic caps and the 2 hinges 7 Ro...

Page 21: ...ICAMENTE ANTES DE COMENZAR Lea estas instrucciones por completo y con detenimiento IMPORTANTE Guarde estas instrucciones para el uso de inspectores el ctricos locales IMPORTANTE Cumpla con todos los c...

Page 22: ...adaptador en Y arandelas y WE1M847 Manguera Larga O POR SEPARADO WE1M847 Manguera Larga y WE1M848 Manguera Corta Instrucciones de instalaci n Incline la secadora de costado y saque los soportes de es...

Page 23: ...r una explosi n incendio o la muerte Esta secadora DEBE tener una ventilaci n al exterior El espacio libre m nimo entre el armario de la secadora y las paredes adyacentes u otras superficies es 0 sobr...

Page 24: ...sta que est firmemente asentada 5 Aseg rese de que la arandela de goma plana se encuentra en su posici n y coloque una manguera de entrada de agua de 4 a 6 pies de largo puede ser necesario comprarla...

Page 25: ...as y el material del conducto V lvula de cierre MATERIALES NECESARIOS Codo de metal de 4 di metro Compuesto o PTFE cinta para tuber as Conector de tuber a de gas flexible Abrazaderas de tuber a 2 o ab...

Page 26: ...est aprobada por CSA International Nunca vuelva a usar conectores flexibles viejos Instale una v lvula de cierre manual individual dentro de 6 pies de la secadora en acuerdo con el C digo Nacional de...

Page 27: ...do del gas F Aplique compuesto para tuber a o cinta PTFE en todas las roscas macho V lvula de apagado Toma a rosca C MO CONECTAR LA SECADORA AL SUMINISTRO DE GAS Instale un codo hembra NPT de 3 8 al f...

Page 28: ...ecadora est instalada en su posici n final Si el circuito tiene un recept culo de 2 clavijas es responsabilidad del propietario de reemplazarlo con un recept culo de 3 clavijas debidamente conectado a...

Page 29: ...secadora no incluido con la la secadora Clasificado UL de 120 240V 30A con 3 o 4 patas Identifique el tipo de enchufe seg n el tomacorriente de la vivienda antes de comprar el cable 4 Placa de cubiert...

Page 30: ...riesgo de descargas el ctricas al brindar un camino con una resistencia menor para la corriente el ctrica Este secadora est equipada con un cable con un conductor para la conexi n a tierra del equipo...

Page 31: ...vivos a los tornillos externos del bloque terminal marcado L1 y L2 B Conecte el cable neutral blanco al centro del bloque terminal marcado N 6 Aseg rese de que la cinta de conexi n a tierra est conect...

Page 32: ...ar o doblar CONDUCTO DE TRANSICI N DE METAL FLEXIBLE SECADORA DE ROPA DE LA LISTA DE UL Si un conducto de metal r gido no puede ser utilizado entonces un conducto de metal flexible aprobado por UL pue...

Page 33: ...ser considerados como un codo de 90 Para el escape lateral agregue un codo de 90 a la tabla Para cada codo adicional de 90 reduzca en 10 pies la longitud permisible del sistema de escape En el c lculo...

Page 34: ...obstrucci n con la abertura apuntando hacia abajo SEPARACI N DE CURVAS Para un mejor desempe o separe todas las curvas con 4 pies de conducto recto como m nimo incluyendo la distancia entre la ltima...

Page 35: ...lo una Derecha s lo modelos a el ctrico Izquierda Parte inferior Vuelva a conectar la porci n cortada A del conducto a la caja del ventilador Aseg rese de que el conducto m s corto se encuentre aline...

Page 36: ...AGREGAR UN CODO DE SALIDA A TRAV S DE LA PARTE INFERIOR DEL GABINETE NIVELE LA SECADORA ENCHUFE LA SECADORA 1 CONFIGURACI N FINAL 2 INICIO DE LA SECADORA Presione el bot n Start Inicio NOTA Si la sec...

Page 37: ...inta Destornillador de punta plana peque a Antes de Comenzar Desenchufe la secadora del tomacorriente A INVERSI N DE LA PUERTA MODELOS DE PUERTA S LIDA 1 Abra la puerta aproximadamente 130 grados Con...

Page 38: ...NVERSI N DE LA PUERTA MODELOS DE PUERTA S LIDA cont 5 Solo modelo GTX52 Quite las dos bisagras y los 8 tornillos 4 de las bisagras y 4 de la puerta exterior Levante la puerta interior con un desatorni...

Page 39: ...s mismas en posiciones opuestas Tapa de pl stico 4 Lado izquierdo del panel frontal Placa ciega Placa de refuerzo 3 Afloje cada tornillo de la bisagra superior en el lado derecho Retire la puerta y co...

Page 40: ...a enchufar la secadora en la salida el ctrica Puerta Sostenga la puerta y ajuste los tornillos Tapa de pl stico 4 Lado derecho del panel frontal B INVERSI N DE LA PUERTA MODELOS CON PANEL DE CRISTAL...

Reviews: