Service: Regeneration and Heavy Duty Backwash
NOTE:
Each of the following functions has a factory set default value. The defaults are:
Regeneration start time
–2:00AM
; Maximum days between regenerations
–0
(display shows
dY–
);
Heavy duty backwash
–OFF
. The defaults are suitable for most installations. However, depending
on water supply quality, household peak water use hours, etc., adjustment is available to meet
specific needs. To make a change, read and do the following.
Regeneration (Start) Time:
At the 2:00 AM regeneration start time, the water softening system begins
regeneration at that time, ending at about 4:00 AM. This is a good time in most households because
water is not in use (see
Automatic Hard Water Bypass During Regeneration
section). If a different time
would be better for your needs, do steps 1, 2, 3, 5, 7, 8 and 9 below to change the starting hour.
Maximum Days Between Regeneration:
The default setting allows the timer to control regeneration
frequency based on water usage readings from the water meter. It provides the most economical
operation. You can set a maximum time (in days) between regenerations. For example, no more
than three days will pass without a regeneration occurring if you set
dY 3
in the display. A 1 to 7 day
setting is available. To make a change from the default setting, do steps 1, 2, 3, 5, 7, 8 and 9 below.
Heavy Duty Backwash:
When set to
ON
, the backwash cycle of regeneration will be 10 minutes long
instead of the normal seven minute length. This is beneficial on some water supplies high in iron
or sediment content. To conserve water, on clean supplies, be sure
OFF
shows. To change this
setting, do steps 1, 2, 3, 5, 7, 8 and 9 below.
Auto Regeneration when Capacity is Low:
The softener will regenerate at the regeneration time only.
Although the cotrol has a look-forward feature which anticipates normal demand, an unusually
high usage may result in a loss of softening capacity. Turning the feature
ON
will cause the softener
to go into a regeneration cycle when 97% of the softening capacity has been used. To change
settings do steps 1, 3, 5, 7, 8 and 9.
Beginning from the present time display, press and hold in the
SET
button until
begins to flash.
Press the
UP
or
DOWN
button to display the desired start time. The
UP
button moves the time
ahead; the
DOWN
button moves the time backward.
Press the
SET
button again, and
flashes.
To set a maximum time (in days) between regenerations, press the
UP
or
DOWN
button.
Press the
SET
button to display
.
Use the
UP
button to change the display to
ON
to increase the backwash time, if desired.
Press the
SET
button and alternately flashes.
Use the
UP
button to turn
Auto Regeneration
cycle on.
Press the
SET
button a final time to return to present time of day.