background image

Dispenser Ice Maker

Manual

MODEL : ID-0450-AN

※ This machine cannot be used in any other country 
    where the electric voltage for its power supply is not available.
※ This product is designed for indoor installation.
    Please be sure to install it indoors.
※ The external appearance, design, color, and/or components 
    of this machine may be changed without prior notice for the sake 
    of the Company's product manufacture.
※ Please read the preparations for safety.
※ For maximum hygiene, be sure to clean and sterilize the product
    on a daily basis.

Summary of Contents for ID-0450-AN

Page 1: ...his product is designed for indoor installation Please be sure to install it indoors The external appearance design color and or components of this machine may be changed without prior notice for the sake of the Company s product manufacture Please read the preparations for safety For maximum hygiene be sure to clean and sterilize the product on a daily basis ...

Page 2: ...5 How to start the product Button operation Function button description FND display window Three drainage functions forced drainage automatic draining water drainage Stop switch 7 Maintenance repair and disinfection Maintenance schedule Cautions for cleaning the external panel stainless steel How to clean and disinfect 6 Required precautions to prevent frost Water removal in water tank and evapora...

Page 3: ...15V 115V should be used Warning Caution SHOULD BE DONE PROHIBITION GROUNDED DO NOT DISASSEMBLE DO NOT TOUCH DISCONNECT POWER PLUG An electrical fire may be caused by a receptacle holding more than one item Do not use an adapter or an extension cord Use a single receptacle for the ice machine If wet towels are wet there is a risk of electric shock A fire may occur if plug is not cleaned Clean the p...

Page 4: ... a risk of fire due to electric shock or short circuit Risk of explosion or fire Do not place heavy objects or containers containing water on the ice maker Do not install the product in a humid place or where there is a risk of water splashing Do not use If the product malfunctions such as smoke or burning smell unplug the power cord to stop operation Do not use Do not use if the outlet is loose o...

Page 5: ...or become damaged The cord or plug may be peeled and there is a risk of fire or electric shock If the cord or plug is peeled or damaged be sure to ask the service to replace it Disassembly forbidden Do not modify or repair the product yourself Prohibition Do not let children hang on the product Do not touch Do not touch or pull on the power plug with wet hands Do not touch Do not damage the inside...

Page 6: ...ock due to short circuit Do not plug in multiple plugs at the same time Connecting multiple plugs to a power strip will cause a fire Disconnect power plug When not in use for a long time remove ice and water to prevent winter frost and unplug the power cord from the outlet Disconnect power plug When cleaning dust or replacing parts unplug the power plug first Disconnect power plug When unplugging ...

Page 7: ...n of the ice maker Caution If there is a risk of slippery water or oil on the floor near the ice maker please wipe it Hand over When transferring this ice maker to another person please hand it along with the instruction manual Do not put your hands or feet on the bottom of the ice maker If you unplug the power plug from the wall outlet and plug it back in again wait at least 5 minutes before rein...

Page 8: ...kaging 92 kg After packaging 101 kg Compressor 1 2 HP Condensation method Air cooled Refrigerant R 404A 400g Deceleration motor Power Supply AC 115 V 60 1PH Rated output 80 W Discharging method Solenoid Installation environment standard Specification 10 38 Water temperature 10 32 Supply water pressure 1 5 kgf Maximum production is based on ambient temperature and water temperature 10 However the d...

Page 9: ...9 3 Appearance and Size Front Rear Unit mm Top Bottom 421 1095 672 Drain box Rubber feet Air filter Drain power Water supply Display panel Ice dispensing lever Ice spout Upper vent ...

Page 10: ...10 We Think of Customer Satisfaction Left side Right side 672 1095 1015 278 90 Detachable to the front ...

Page 11: ...ast 20cm away from the wall For cleaning and maintenance of the auger 100cm space should be reserved above the top of the ice maker Never block the upper vents and do not place any load on it Transport with safety gloves when moving the product it is very dangerous to damage the product or damage to the body if the product falls by damage or slipping on a sharp place 20cm 100cm wall Two people sho...

Page 12: ... observe the following Since the product makes use of water proper water supply and draining facility are required Water may leak during installation or operation for diverse reasons Thus proper draining must be prepared Since there is danger of electric shock due to moisture from leak be sure to observe the following 1 When installing the product indoors be sure to have a natural drainage facilit...

Page 13: ...r switch Ice moving wing Water supply tank cooler Drain valve Ice making motor Kiosk connection jack Power line Cooling motor Drainage connection Condenser Water supply Cooling control valve Control box Discharge solenoid Water selection valve Ejection lever Rubber feet Air filter Function selection switch ...

Page 14: ...n outlet Connection method of water supply and drainage Please connect a hose with an inner diameter of Φ20mm or more for the ice making drain hose and the drain outlet should be 5cm above the drain floor level If the drain outlet dip in the drainage the drainage may flow back into the ice maker and damage the product and the floor After the installation is complete please operate the product and ...

Page 15: ...ou are using an AC 115V outlet without a ground terminal connect the ground wire to the copper plate and bury it in the ground Do not ground in these places Never connect to a gas pipe water pipe pipe lightning rod telephone line or connection Plastic water pipes and non insulated materials do not have a grounding effect AC 115V only outlet Copper plate Equal to or more than 75 cm Ground wire A Gr...

Page 16: ...er supply Open the front door and turn on the power switch to start the Ice making operation Turn the ICE MAKING OFF WASH switch to ICE MAKING There is a slight difference depending on the ambient temperature and water temperature ice starts to be generated from about 3 minutes after starting the ice making operation After about 70 minutes the reservoir will be full of ice You can use ice after ab...

Page 17: ... F1 When ERROR occurs ICE WATER ICE WATER button will flicker in order and will disappear when restarting after the action against the ERROR Service cycle setting notification parts check replacement cycle notification If the motor is running for more than 10 000 hours the corresponding lamp blinks for 5 seconds in the initial stage of the ice maker If the motor is operated for more than 11 000 ho...

Page 18: ...9 9 and 0 1 is 1000 hours Check the AUGER usage time FND displays Year Month Day Time sequentially Check the AUGER usage time FND displays Year Month Day Time sequentially Displays EVA OUT temperature Check the number of times the wash is complete After washing the product set the mode switch to OFF and press the Increase Decrease button simultaneously while the FND version is displayed and the nu...

Page 19: ...switch off and then on again the ICE MAKING OFF WASH switch at ICE MAKING position to operate the function Clean the water line and ice making cylinder thoroughly FND 1st 2nd drain time 30 seconds 5 99 seconds Set Unit of one second Water supply operation to high water level after drainage FND 3rd 4th digits number of repetition Reference 3 times 1 9 times With the power switch turned on turn the ...

Page 20: ...ND window Forced drainage will be done for 30 seconds 2 Turn off the power switch and disconnect the power plug from the outlet 3 Remove the upper panel the back panel However it does not work in full text 4 Remove the evaporator cylinder drain hose clamp and remove the hose and wait until the ice in the evaporator cylinder completely melts down It is possible to remove internal water quickly by u...

Page 21: ...repared as described in the instructions for disinfection in the manual into the evaporator condensate drain pan 2 Take care not to overflow the drain pan 3 This disinfectant solution will flow out through the geared motor drain pan and drain passage 4 Rinse repeatedly with a glass of clean water Ice maker and reservoir 1 Always check that it is kept clean Ice exit fixing seal bolt 1 Check for lea...

Page 22: ...mmediately with a mild detergent However when the rust has gotten really bad it must be removed with 15 nitric acid solution or commercially available stainless steel cleaner 4 Rust from exhaust gas or acid rain In environments such as a factory complex or heavy transport sites the product will become contaminated in a short amount of time due to exhaust fumes or acid rain and rust spots will quic...

Page 23: ...ⓒ Wash the water level sensor thoroughly with clean water ⓓ Fix the level sensor to the correct position 9 Switch the ICE MAKING OFF WASH switch to the ICE MAKING position to start the ice maker Keep it running until ice making stops Water supply valve should be locked so that water is not supplied 10 Switch the front ICE MAKING OFF WASH switch to the WASH position and drain the remaining water in...

Page 24: ...s 12 Switch the ICE MAKING OFF WASH switch to the WASH position and let the remaining water drain out for 5 minutes 13 Turn the power switch to OFF and disconnect the power plug from the outlet 5 Disinfection procedure final 1 Mix the disinfection solution in a new bowl 2 Check that the water valve is closed the power switch is turned off and the power plug is disconnected from the outlet and then...

Page 25: ...25 8 Circuit Diagram ...

Page 26: ... abnormal cold cycle Automatic return after action Stop compressor Stop motor after operating 10 seconds High pressure switch error Occurs when High pressure switch is OPEN 3 times or more Contact service representative Start operation after action Stop compressor Stop motor after operating 10 seconds Water supply error When water level is not detected by the water level sensor due to no water sup...

Page 27: ...heck the water source 4 Is water valve working Check and contact the customer service center 3 Takes too long to make ice cubes 1 Ice maker is too dirty too much dust Air cooled type Disassemble the front cover remove the dust filter and clean it with a vacuum cleaner Too much dust deteriorates performance and may make the product use too much power 2 Is ambient temperature not too high or low Ope...

Page 28: ...mage due to external impact or dropping 8 Failure due to natural disasters lightning fire earthquake flood tsunami etc 9 Consumable parts have reached end of life packing cleaning brush etc 10 If the malfunction occurred by putting foreign substances into the product water drink coffee toy etc 11 In case of product breakdown or malfunction due to external impact during installation and use 12 If t...

Page 29: ...29 MEMO ...

Page 30: ...30 We Think of Customer Satisfaction MEMO ...

Page 31: ...31 ...

Page 32: ...3240464 10 Online Internet Service http www icetro com ...

Reviews: