Appendix A. Command Language Interface (CLI)
74
PACSystems PROFINET Managed Industrial Ethernet Switches User Manual
GFK-3030
A.3.3.14
account add <username>
Description
Add an account.
Syntax
username <word31> privilege <0-15> password encrypted <word4-44>
Parameter
Name
Description
< word31>
Valid values
: 1 ~ 31 characters
Type
: Mandatory
<0-15>
Valid values
: 0 ~ 15
Type
: Mandatory
< word4-44>
Valid values
: 4-44 characters
Type
: Mandatory
A.3.3.15
account delete <username>
Description
Delete an account.
Syntax
no username <word31>
Parameter
Name
Description
< word31>
Valid values
: 1 ~ 31 characters
Type
: Mandatory
A.3.3.16
syslog {enable|disable}
Description
Disable or enable syslog service.
Syntax
logging on
no logging on
Parameter
None
A.3.3.17
Configuration save and replace
Description
Save and install configuration
Syntax
copy { startup-config | running-config | <Filename> } { startup-config | running-config |
< Filename > } [ syntax-check ]
Parameter
Name
Description
running-config Currently running configuration
startup-config
Startup configuration
syntax-check
Perform syntax check on source configuration
Filename
File in FLASH or on TFTP server
Summary of Contents for GLM064