background image

5

Safety Instructions

Installation Instructions

Operating Instructions

Care and Cleaning

T

roubleshooting Tips

Customer Service

LP and natural gas have an odorant added to aid in detecting a gas leak. Some 
people may not physically be able to smell or recognize this odorant. If you are unsure or unfamiliar with
the smell of LP or natural gas, ask the gas supplier. Other conditions, such as “odorant fade”, which
causes the odorant to diminish in intensity, can also hide or camouflage a gas leak.

DANGER!

LIQUEFIED PETROLEUM (LP-PROPANE OR BUTANE)
AND NATURAL GAS MODELS

Water heaters utilizing LP gas are different
from natural gas models. A natural gas
water heater will not function safely on LP
gas and vice versa. 

No attempt should ever be made to convert
the water heater from natural gas to LP
gas. To avoid possible equipment damage,
personal injury or fire, do not connect the
water heater to a fuel type not in
accordance with the unit data plate. LP for
LP units. Natural gas for natural gas units.
These units are not certified for any other
fuel type.

LP appliances should not be installed below
grade (for example, in a basement) if such
installation is prohibited by federal, state
and/or local laws, rules, regulations or
customs.

LP gas must be used with great caution. It
is heavier than air and will collect first in
lower areas making it hard to detect at
nose level.

Before attempting to light the water
heater, make sure to look and smell for gas
leaks. Use a soapy solution to check all gas
fittings and connections. Bubbling at a
connection indicates a leak that must be
corrected. When smelling to detect an LP
leak, be sure to sniff near the floor also.

Gas detectors are recommended in LP  &
natural gas applications and their
installation should be in accordance with
the manufacturer’s recommendations
and/or local laws, rules, regulations or
customs.

It is recommended that more than one
method, such as soapy solution, gas
detectors, etc., be used to detect leaks in
gas applications.

DANGER: If a gas leak is present or

suspected:

Do not

attempt to find the cause yourself.

Do not

try to light any appliance.

Do not

touch any electrical switch.

Do not

use any phone in your building.

Leave the house immediately and make sure
your family and pets leave also.

Leave the doors open for ventilation and
contact the gas supplier, a qualified service
agency or the fire department.

Stay away from the house (or building) until
the service call has been made, the leak is
corrected and a qualified agency has
determined the area to be safe.

!

Summary of Contents for GG75T06ASK

Page 1: ...al injury or death Model GG Series The purpose of this manual is twofold one to provide the installer with basic directions and recommendations for the proper installation and adjustment of the water...

Page 2: ...on a label on the appliance Staple sales slip or cancelled check here Proof of the original purchase date is needed to obtain service under the warranty IMPORTANT Fill out and return the Consumer Pro...

Page 3: ...HE WATER HEATER Gasoline as well as other flammable materials and liquids adhesives solvents etc and the vapors they produce are extremely dangerous Do not handle use or store gasoline or other flamma...

Page 4: ...ER Hotter water increases the Potential for Hot Water SCALDS D A N G E R HOT Water temperature over 125 F can cause severe burns instantly or death from scalds Children disabled and elderly are at hig...

Page 5: ...ed by federal state and or local laws rules regulations or customs LP gas must be used with great caution It is heavier than air and will collect first in lower areas making it hard to detect at nose...

Page 6: ...d to a qualified technician SAFETY PRECAUTIONS IMPORTANT SAFETY INFORMATION READ ALL INSTRUCTIONS BEFORE USING WARNING For your safety the information in this manual must be followed to minimize the r...

Page 7: ...its must comply with local codes The water heater must be located so it is not subject to physical damage for example by moving vehicles area flooding etc The water heater should be installed as close...

Page 8: ...mbustion and ventilation air supplied from outdoors or a freely ventilated attic or crawl space If air is supplied from outdoors directly or through vertical ducts there must be two openings located a...

Page 9: ...shion built in that compresses as the system pressure increases thereby relieving the over pressure condition and eliminating the repeated operation of the relief valve Other methods of controlling th...

Page 10: ...nd of the discharge line should not be threaded or concealed and should be protected from freezing No valve of any type restriction or reducer coupling should be installed in the discharge line To Fil...

Page 11: ...sting the Gas Supply System The water heater and its manual gas shut off valve must be disconnected from the gas supply piping system during any high pressure testing of that system at pressures in ex...

Page 12: ...energy saving devices may shorten the life of the water heater and may endanger life and property The manufacturer disclaims any responsibility for such loss or injury resulting from the use of such...

Page 13: ...ments Heat Traps For increased energy efficiency some water heaters have been supplied with factory installed 3 4 NPT heat traps in the hot outlet line and cold water inlet line These heat traps may r...

Page 14: ...clear of the base of the heater Gas Supply Gas line equipped with shut off valve union and sediment trap Approved pipe joint compound used Soap and water solution used to check all connections and fi...

Page 15: ...l and take precedent over these instructions Tee fitting for vertical hot water supply lines Combination Potable and Space Heating Application Tee fitting must be installed as shown This insures that...

Page 16: ...s printed in this manual Failure to do so can result in unsafe operation of the water heater resulting in property damage bodily injury or death Should you have any problems reading or following the i...

Page 17: ...Failure to do so can result in unsafe operation of the water heater resulting in property damage bodily injury or death Should you have any problems reading or following the instructions in this manu...

Page 18: ...must be used open doors and windows for ventilation and all gas burning appliances in the vicinity should be shut off including their pilot lights to avoid vapors lighting NOTICE Flammable vapors may...

Page 19: ...sure to read and follow the warnings outlined in this manual and on the label on the water heater This label is located on the water heater near the gas control thermostat access panel Mixing valves...

Page 20: ...ays supervise young children or others who are incapacitated The gas control thermostat is constructed with a built in safety shut off device designed to shut off the gas supply to the burner if the p...

Page 21: ...he water It is therefore not uncommon for hard water deposits to accumulate in the bottom of the tank If allowed to accumulate these solids can cover the gas control thermostat sensors causing the sen...

Page 22: ...erformed only by qualified service personnel Figure A Main burner and pilot flame pattern Cast iron burner Figure B Main burner and pilot flame pattern Sheet metal burner Care and cleaning of the wate...

Page 23: ...ction of this the pilot correctly positioned manual Pilot orifice clogged The pilot should be cleaned or replaced by a qualified service technician Pilot tube pinched or The pilot should be cleaned re...

Page 24: ...t for the water heater to recover after an abnormal no hot water exceeded the capacity demand of the water heater Low gas pressure Check gas supply pressure and manifold pressure The pilot may be out...

Page 25: ...onnel Draft hood Drain valve shroud Burner supply tube Inner door Flue baffle hanger Anode rod Flue baffle collar Flue baffle Dip tube Dip tube gasket Pilot supply tube Thermocouple Piezo Ignitor Stri...

Page 26: ...ntacting the manufacturer the following information will be requested Model and serial number of the water heater as shown on the rating plate attached to the jacket of the heater Address where the wa...

Page 27: ...27 Rheem Manufacturing Company Warranty Registration Department P O Box 34070 Louisville KY 40232 4070 Please place in envelope and mail to Cut here Cut here...

Page 28: ...Mr Ms Mrs Miss Street Address City State Date Placed In Use Month Day Year Zip Code Apt Last Name Phone Number _ _ Complete and mail this Consumer Product Ownership Registration today After mailing th...

Reviews: