background image

23

Problem

Possible Causes

What To Do

Condensation

This usually happens when  

This is normal. After the water in the tank warms 

a new water heater is 

up the condensation will disappear. If, however, the 

filled for the first time. 

condition persists, examine the piping and fittings 
for possible leaks.

Moisture from the products

This is normal and will disappear in time. Excessive 

of combustion condensing 

condensation can cause pilot outage.

on the tank surface.

An undersized water 

Use a water heater size that meets the requirements 

heater will cause 

of your needs.

condensation. 

Yellow flame 

Scale on top of the burner.

Shut off the water heater and remove scale.

or sooting

Combustion air inlets or

Remove lint or debris and inspect air inlet opening 

flue-way restricted. 

for restriction. 

Not enough combustion or

Proper operation of the water heater requires air for 

ventilation air supplied to

combustion and ventilation. See the Combustion and

the water heater location.

Ventilation Air information in the Locating the water 
heater section of this manual.

Unable to light 

Gas Cock Knob not

See the Lighting the water heater section of this 

the pilot

correctly positioned.

manual. 

Pilot orifice clogged.

The pilot should be cleaned or replaced by a qualified 
service technician.

Pilot tube pinched or 

The pilot should be cleaned, repaired or replaced by a 

clogged.

qualified service technician.

Air in gas line.

Contact a qualified service technician to purge the air
from the gas line.

Pilot does not stay 

Loose thermocouple.

The connection at the gas control (thermostat) should

lit when the RED

be tightened by a qualified service technician.

button is released 

Thermocouple breakdown.

The thermocouple should be replaced by a qualified 
service technician.

Safety magnet breakdown.

The gas control (thermostat) should be replaced by a  
qualified service technician.

Thermostat’s single 

The gas control (thermostat) should be replaced by a  

use gas shut-off device 

qualified service technician.

has opened.

CAUTION: For your safety DO NOT attempt repair of gas piping, gas control (thermostat), burners, vent

connectors or other safety devices. Refer repairs to qualified service personnel.

Before You Call For Service…

Troubleshooting Tips
Save time and money! Review the charts on
the following pages first and you may not
need to call for service.

Safety Instructions

Installation Instructions

Operating Instructions

Care and Cleaning

T

roubleshooting Tips

Customer Service

Summary of Contents for GG75T06ASK

Page 1: ...al injury or death Model GG Series The purpose of this manual is twofold one to provide the installer with basic directions and recommendations for the proper installation and adjustment of the water...

Page 2: ...on a label on the appliance Staple sales slip or cancelled check here Proof of the original purchase date is needed to obtain service under the warranty IMPORTANT Fill out and return the Consumer Pro...

Page 3: ...HE WATER HEATER Gasoline as well as other flammable materials and liquids adhesives solvents etc and the vapors they produce are extremely dangerous Do not handle use or store gasoline or other flamma...

Page 4: ...ER Hotter water increases the Potential for Hot Water SCALDS D A N G E R HOT Water temperature over 125 F can cause severe burns instantly or death from scalds Children disabled and elderly are at hig...

Page 5: ...ed by federal state and or local laws rules regulations or customs LP gas must be used with great caution It is heavier than air and will collect first in lower areas making it hard to detect at nose...

Page 6: ...d to a qualified technician SAFETY PRECAUTIONS IMPORTANT SAFETY INFORMATION READ ALL INSTRUCTIONS BEFORE USING WARNING For your safety the information in this manual must be followed to minimize the r...

Page 7: ...its must comply with local codes The water heater must be located so it is not subject to physical damage for example by moving vehicles area flooding etc The water heater should be installed as close...

Page 8: ...mbustion and ventilation air supplied from outdoors or a freely ventilated attic or crawl space If air is supplied from outdoors directly or through vertical ducts there must be two openings located a...

Page 9: ...shion built in that compresses as the system pressure increases thereby relieving the over pressure condition and eliminating the repeated operation of the relief valve Other methods of controlling th...

Page 10: ...nd of the discharge line should not be threaded or concealed and should be protected from freezing No valve of any type restriction or reducer coupling should be installed in the discharge line To Fil...

Page 11: ...sting the Gas Supply System The water heater and its manual gas shut off valve must be disconnected from the gas supply piping system during any high pressure testing of that system at pressures in ex...

Page 12: ...energy saving devices may shorten the life of the water heater and may endanger life and property The manufacturer disclaims any responsibility for such loss or injury resulting from the use of such...

Page 13: ...ments Heat Traps For increased energy efficiency some water heaters have been supplied with factory installed 3 4 NPT heat traps in the hot outlet line and cold water inlet line These heat traps may r...

Page 14: ...clear of the base of the heater Gas Supply Gas line equipped with shut off valve union and sediment trap Approved pipe joint compound used Soap and water solution used to check all connections and fi...

Page 15: ...l and take precedent over these instructions Tee fitting for vertical hot water supply lines Combination Potable and Space Heating Application Tee fitting must be installed as shown This insures that...

Page 16: ...s printed in this manual Failure to do so can result in unsafe operation of the water heater resulting in property damage bodily injury or death Should you have any problems reading or following the i...

Page 17: ...Failure to do so can result in unsafe operation of the water heater resulting in property damage bodily injury or death Should you have any problems reading or following the instructions in this manu...

Page 18: ...must be used open doors and windows for ventilation and all gas burning appliances in the vicinity should be shut off including their pilot lights to avoid vapors lighting NOTICE Flammable vapors may...

Page 19: ...sure to read and follow the warnings outlined in this manual and on the label on the water heater This label is located on the water heater near the gas control thermostat access panel Mixing valves...

Page 20: ...ays supervise young children or others who are incapacitated The gas control thermostat is constructed with a built in safety shut off device designed to shut off the gas supply to the burner if the p...

Page 21: ...he water It is therefore not uncommon for hard water deposits to accumulate in the bottom of the tank If allowed to accumulate these solids can cover the gas control thermostat sensors causing the sen...

Page 22: ...erformed only by qualified service personnel Figure A Main burner and pilot flame pattern Cast iron burner Figure B Main burner and pilot flame pattern Sheet metal burner Care and cleaning of the wate...

Page 23: ...ction of this the pilot correctly positioned manual Pilot orifice clogged The pilot should be cleaned or replaced by a qualified service technician Pilot tube pinched or The pilot should be cleaned re...

Page 24: ...t for the water heater to recover after an abnormal no hot water exceeded the capacity demand of the water heater Low gas pressure Check gas supply pressure and manifold pressure The pilot may be out...

Page 25: ...onnel Draft hood Drain valve shroud Burner supply tube Inner door Flue baffle hanger Anode rod Flue baffle collar Flue baffle Dip tube Dip tube gasket Pilot supply tube Thermocouple Piezo Ignitor Stri...

Page 26: ...ntacting the manufacturer the following information will be requested Model and serial number of the water heater as shown on the rating plate attached to the jacket of the heater Address where the wa...

Page 27: ...27 Rheem Manufacturing Company Warranty Registration Department P O Box 34070 Louisville KY 40232 4070 Please place in envelope and mail to Cut here Cut here...

Page 28: ...Mr Ms Mrs Miss Street Address City State Date Placed In Use Month Day Year Zip Code Apt Last Name Phone Number _ _ Complete and mail this Consumer Product Ownership Registration today After mailing th...