14
49-90570-2
Installation
Washer
Instructions
If you have any questions, call GE Appliances at 800.GE.CARES
(800.432.2737) or visit our Website at: GEAppliances.com
In Canada, call 800.561.3344 or visit GEAppliances.ca
TOOLS REQUIRED FOR
WASHER INSTALLATION
Level
Wrench (provided)
Channel-lock adjustable pliers
PARTS SUPPLIED
BEFORE YOU BEGIN
Read these instructions completely and carefully.
•
IMPORTANT –
Save these
instructions for local inspector’s use.
•
IMPORTANT –
Observe all
governing codes and ordinances.
•
Note to Installer –
Be sure to leave these
instructions with the Consumer.
•
Note to Consumer –
Keep these
instructions for future reference.
•
Skill level –
Installation of this appliance requires
basic mechanical and electrical skills.
•
Completion time –
1-3 hours
• Proper installation is the responsibility of the
installer.
• Product failure due to improper installation is not
covered under the Warranty.
Water Hoses (2)
(Flat washers
pre-installed)
Drain Hose Guide
DO NOT Install the Washer:
1.
In an area exposed to dripping water or outside weather
conditions. The ambient temperature should never be
below 60°F (15.6°C) for proper washer operation.
2.
In an area where it will come in contact with curtains or
drapes.
3.
On carpet. The floor
MUST
be a hard surface with a
PD[LPXPVORSHRIƎSHUIRRWFPSHUFP
To make sure the washer does not vibrate or move,
you may have to reinforce the floor.
NOTE:
,IIORRULVLQSRRUFRQGLWLRQXVHƎLPSUHJQDWHG
plywood sheet solidly attached to existing floor covering.
IMPORTANT:
Minimum Installation Clearances
•
:KHQLQVWDOOHGLQDOFRYH6LGHV5HDU ´DQG7RS Ǝ
• When installed in closet: Sides/Rear = 0” and Top/Front =
ƎFP
• Consideration must be given to provide adequate
clearance for installation and service.
• Closet doors must be louvered or otherwise ventilated
and have at least 60 square inches (387.1 cm
2
) of open
area. If the closet contains both a washer and a dryer,
doors must contain a minimum of 120 square inches
(774.2 cm
2
) of open area.
LOCATION OF YOUR WASHER
MOBILE HOME INSTALLATION:
Installation must conform to Standard for Mobile Homes, ANSI A119.1 and National Mobile Home Construction and
Safety Standards Act of 1974 (PL93-383).