45
User Manual V1.0-2022-05-10
10 Technical Parameters
Technical Data
GEP4.0 -3 -10
GEP5.0 -3 -10 GEP6.0 -3 -10
GEP8.0 -3 -10 GEP8-3-AU10
AC Grid Frequency Range
(Hz)
45~55 / 55~65
45~55 /
55~65
45~55 / 55~65
45~55 /
55~65
45~55 / 55~65
Max. Output Current (A)
6.4
8.0
9.6
12.8
12.8
Max. Output Fault
Current (Peak and
Duration) (A)
16A@5ms
20A@5ms
24A@5ms
32A@5ms
32A@5ms
Inrush Current (Peak and
Duration) (A)
80A@50us
80A@50us
80A@50us
80A@50us
80A@50us
Nominal Output Current
(A)
5.8
7.2
8.7
11.6
11.6
Power Factor
~1 (Adjustable from 0.8 leading to 0.8 lagging)
Max. Total Harmonic
Distortion
<3%
<3%
<3%
<3%
<3%
Maximum Output
Overcurrent Protection
(A)
22.13
22.13
22.13
38.37
38.37
Efficiency
Max. Efficiency
98.3%
98.3%
98.3%
98.3%
98.3%
European Efficiency
97.6%
97.6%
97.6%
97.6%
97.6%
CEC Efficiency
97.8%
97.8%
97.8%
97.8%
97.8%
Protection
PV Insulation Resistance
Detection
Integrated
Residual Current
Monitoring
Integrated
PV Reverse Polarity
Protection
Integrated
Anti-islanding Protection
Integrated
AC Overcurrent
Protection
Integrated
AC Short Circuit
Protection
Integrated
AC Overvoltage
Protection
Integrated
DC Switch
Integrated
DC Surge Protection
Type II
AC Surge Protection
Type III(Type II Optional)
AFCI
Optional