Programming Site Data
1-15
April 2008
Pipe OD (cont.)
Pipe Wall
6.
Enter the known thickness of the
Pipe Wall
, in the same units used
for the pipe OD. Press
[ENT]
. (The meter will only accept values
from 0 to 4 in.)
If the pipe wall thickness is not known and cannot be conveniently
measured, look up the value in a table of standard pipe size data or
use the Model GC868’s on-line
Help Menu
.
Fluid Type
7.
Press
[F1]
= natural gas,
[F2]
= air,
[F3]
= steam, or
[F4]
= any other
gas to select the
Fluid Type.
If
OTHER
was selected, enter the speed
of sound (in feet per second) in the gas to be measured. Press
[ENT]
. (The meter will only accept values from 125 to 9000 ft/sec.)
Reynolds Correction
8.
The
Reynolds Correction
factor is a number based on the
kinematic viscosity and flow rate of the gas. At the
prompt, press
[F1]
to turn Reynolds Correction off
,
or
[F2]
to turn it on
.
•
If you select Reynolds Correction, the GC868 asks for the
Kinematic Viscosity
of the gas (available in the brochure
Sound
Speeds and Pipe Size Data
, 914-004). Use the numeric keys to
enter the correct value and press
[ENT]
.
Calibration Factor
9.
Enter a value for the flow
Calibration Factor
and press
[ENT]
. The
default value is 1.00. (The meter will only accept values from
0.5000 to 2.0000.) If you are using wetted transducers, you have
completed programming in the
PIPE
menu.
Number of Traverses
10.
Press
[F1]-[F4]
to select the desired number of traverses (times the
ultrasonic signal traverses the pipe, from 1 to 9).
Note:
Most clamp-on gas applications require a single traverse
(1(Z)).
Table 1-4: Available Pipe OD Units
English
Metric
inch = pipe OD in inches
mm = pipe OD in millimeters
feet = pipe OD in feet
m = pipe OD in meters
in/PI = pipe circumference
in inches
mm/PI = pipe circumference
in millimeters
ft/PI = pipe circumference
in feet
m/PI = pipe circumference
in meters
Summary of Contents for DigitalFlow GC868
Page 8: ...Chapter 1 ...
Page 61: ...Chapter 2 ...
Page 78: ...Chapter 3 ...
Page 91: ...Chapter 4 ...
Page 105: ...Chapter 5 ...
Page 111: ...Chapter 6 ...
Page 123: ...Appendix A ...
Page 132: ...Appendix B ...
Page 133: ...Data Records Option Cards Installed B 1 Initial Setup Data B 2 ...
Page 136: ...Appendix C ...
Page 156: ...Appendix D ...