OPEN

GAS VALVE.

APPLY PIPE COMPOUND

TO ALL MALE THREADS.

Tighten all connections using two adjustable wrenches.

Do not overtorque gas connections!

APPLY PIPE COMPOUND

TO THE ADAPTER AND

DRYER GAS INLET.

NEW METAL

FLEXIBLE GAS

LINE CONNECTOR

ADAPTER

ELBOW

ITEMS NOT SUPPLIED

ADAPTER

SHUT-OFF

VALVE

PIPE SIZE

AT LEAST 1/2"

1/8" NPT PIPE

PLUG FOR

CHECKING GAS

INLET PRESSURE

3/8" NPT

Tighten the flexible

gas line using two

adjustable wrenches.

Installation Instructions

3 RECONNECTING GAS

3

       

WARNING - NEVER USE AN OPEN

FLAME TO TEST FOR GAS LEAKS.

4 LEAK TEST

Check all connections for leaks with soapy solution or equivalent.
Apply soap solution. 

Leak test solution must not contain ammo-

nia which could cause damage to the brass fittings.

 If leaks are

found, close valve, retighten the joint, and repeat the soap test.

Note:  The connector and fittings are designed for use only on the 
original installation and are not to be reused for another appliance 
or at another location.  Keep flare end of adaptor free of grease, oil 
and thread sealant.
Caution:  Use adapters as shown.  Connector nuts must not be 
connected directly to pipe threads.  

Listed connector ANSI Z21.24 / CSA 6.10

Summary of Contents for DBVH520GJ

Page 1: ...ey are bent MATERIALS YOU WILL NEED LEVEL 8 PIPE WRENCH EXHAUST HOOD FLEXIBLE GAS LINE CONNECTOR SOAP SOLUTION FOR LEAK DETECTION PIPE COMPOUND DUCT TAPE GLOVES SAFETY GLASSES 4 DIAM METAL ELBOW 10 ADJUSTABLE WRENCHES x2 4 DUCT CLAMPS OR 4 SPRING CLAMPS x2 x2 TOOLS YOU WILL NEED SLIP JOINT PLIERS FLAT BLADE SCREWDRIVER 4 DIA FLEXIBLE METAL SEMI RIGID UL LISTED TRANSITION DUCT IF NEEDED KIT WX08X10...

Page 2: ...Installation must conform to local codes and ordinances or in their absence the NATIONAL FUEL GAS CODE ANSI Z223 This gas dryer is equipped with a Valve Burner Assembly for use only with natural gas Using conversion kit WE25X0217 your local service organization can convert this dryer for use with propane LP gas ALL CONVERSIONS MUST BE MADE BY PROPERLY TRAINED AND QUALIFIED PERSONNEL AND IN ACCORDA...

Page 3: ...GAS 3 WARNING NEVER USE AN OPEN FLAME TO TEST FOR GAS LEAKS 4 LEAK TEST Check all connections for leaks with soapy solution or equivalent Apply soap solution Leak test solution must not contain ammo nia which could cause damage to the brass fittings If leaks are found close valve retighten the joint and repeat the soap test Note The connector and fittings are designed for use only on the original ...

Page 4: ...s the type of exhaust hood wall cap and all conditions noted below The maximum exhaust length for rigid metal duct is shown in the table below EXHAUST SYSTEM CHECKLIST HOOD OR WALLCAP Terminate in a manner to prevent back drafts or entry of birds or other wildlife Termination should present minimal resistance to the exhaust air flow and should require little or no maintenance to prevent clogging N...

Page 5: ...t longer than specified in the exhaust length table Longer ducts can accumulate lint creating a potential fire hazard Never install a screen in or over the exhaust duct This will cause lint to accumulate creating a potential fire hazard Do not assemble ductwork with any fasteners that extend into the duct These fasteners can accumulate lint creating a potential fire hazard Provide an access for in...

Page 6: ...STALLATION 11 MOBILE OR MANUFACTURED HOME INSTALLATION Installation Instructions Exhausting CONNECTING THE DRYER TO HOUSE VENT 6 DO NOT SIT DRYER ON FLEXIBLE EXHAUST DO NOT USE EXCESSIVE EXHAUST LENGTH DO NOT CRUSH FLEXIBLE EXHAUST AGAINST WALL DON T Rigid metal transitions ducts reduce the risk of crushing and kinking Never install flexible metal duct in walls ceilings floors or other enclosed sp...

Page 7: ...ryer when inserting the duct WARNING PROTECT YOUR HANDS AND ARMS FROM SHARP EDGES WHEN WORKING INSIDE CABINET Cut the duct as shown and keep portion A TAB LOCATION Through the rear opening locate the tab in the middle of the appliance base Lift the tab to about 45 using a flat blade screwdriver Reconnect the cut portion A of the duct to the blower housing Make sure that the fixing hole is aligned ...

Page 8: ... plate Kit WE1M454 available from your local service provider Place dryer in final location ADDING ELBOW FOR EXHAUST THROUGH BOTTOM OF CABINET WARNING NEVER LEAVE THE BACK OPENING WITHOUT THE PLATE For Questions on Installation Call 1 800 626 2003 US or 1 800 561 3344 Canada 500A436P010 Pub 31 16229 Insert the elbow through the rear opening and connect it to the dryer internal duct Apply duct tape...

Page 9: ...ay the door down on a soft protected flat surface so that the inner part faces upward door resting on the handle side 5 Remove the 6 large tapping screws 10 located around the perimeter of the door outlining the gasket and the 2 machine screws 8 on the hinge side 6 With the screws removed turn the door over and separate the silver cover part of the door from the door frame and set 7 Unlock the 4 t...

Page 10: ...ve the 2 nuts washers and the 2 machine screws 8 10 Remove the hinge assembly by removing the 2 machine screws 8 that fasten it to the frame Pull the hinge assembly out and set it aside 11 Place the hinge assembly in the opposite side of the door Align the hinge holes with the door holes REMOVE HINGE REINSTALL HINGE ASSEMBLY 12 Loosely fasten the hinge assembly to the edge using 2 machine screws 8...

Page 11: ...ver onto the inner door and lock in place with the 4 tabs REINSTALL NUTS AND HINGE COVER REASSEMBLE DOOR ASSEMBLY 19 After reversing door there will be a mismatch between the outer door and the inner door Make sure that the handle part of the outer door is opposite the hinge as shown 16 Secure the hinge cover with the 2 tapping screws 8 Outer Door Inner Door Top of Door Place the door on its edge ...

Page 12: ...htening the partially fastened screw above MOVE STRIKE BRACKET 21 Using a putty knife or any other flat tool remove the 5 plastic screw caps located on the dryer where the door will be installed and install them on the opposite side REINSTALL DOOR ASSEMBLY WARNING LABEL ALL WIRES PRIOR TO DISCONNECTING WHEN SERVICING CONTROLS WIRING ERRORS CAN CAUSE IMPROPER AND DANGEROUS OPERATION AFTER SERVICING...

Page 13: ...ROUGH IN DIMENSIONS 13 30 5 8 27 40 1 4 53 5 8 39 1 8 13 3 8 11 3 4 17 27 1 5 8 4 1 2 31 1 8 41 1 2 11 3 4 ...

Page 14: ...NOTES ...