background image

31-11072-1

5

Installation Instructions

PREPARING THE OPENING (Cont)

3

  MINIMUM CLEARANCES TO 

ADJACENT WALLS & CABINETS

If a 30” clearance between the cooktop and overhead 
combustible materials or metal cabinet cannot be 
maintained, then a minimum clearance of 24” is 
required and the underside of the cabinets above the 
cooktop must be protected with not less than 1/4” 
insulating millboard covered with sheet metal not less 
than 30 gage (0.0125”) thick.
A ventilation hood may be installed above the cooktop. 
See the ventilation hood installation instructions for the 
appropriate dimensions and clearances.

5

 VERTICAL CLEARANCE

Allow 5” minimum 
vertical clearance from 
the cooktop bottom (or 
8-1/4” minimum depth 
from the countertop) to 
any combustible surfaces,  
such as a cabinet drawer.

4

  

Make sure the wall coverings, countertop and 
cabinets around the cooktop can withstand heat 
(up to 200°F) generated by cooktop.

6

  

For Americans with Disabilities Act (ADA) 
Forward Approach Installation Only:

NOTE:

 The enclosure must be made of wood 

material. Also, an access panel is required for the 
junction box, hold-down brackets, and service.

Wall covering, 
cabinets and 
countertop must 
withstand heat up 
to 200°F. 

13” max. Depth 
of unprotected 
overhead cabinets

30” min. 
Clearance from 
countertop to 
unprotected 
overhead 
surface

30” min. for 
30” cooktop
36” min. for 
36” cooktop

2” min. Clearance 
from cutout to 
nearest vertical 
wall or cabinet on 
left side of the unit 
below the 15” MIN. 
clearance height. 

15” min. Clearance 

from countertop 

to underside of 

nearest cabinets 

on both sides of 

cooktop, including 

any light rails.

1 1/2” min. (30”) and 

2” min. (36”) Clearance 

from cutout to nearest 

vertical wall or cabinet 

on right side of the unit 

below the 15” MIN. 

clearance height.

DRAWER

5" 

8-1/4" 

DRAWER

For models with 
no drop box, 
allow 5” minimum 
depth between the 
countertop and an 
enclosure. (JP3030, 
JP3530, JP3036, and 
JP3536)

For electronic 
touch and backlit 
knob models, allow  
6-1/2” minimum 
depth between the 
countertop and an 
enclosure. 
(All other models)

5"

6 1/2"

Drop 
box

Summary of Contents for CP9530D

Page 1: ...mproper installation is NOT covered under warranty 30 and 36 Electric Cooktop Radiant Excludes Down Draft Models MATERIALS YOU WILL NEED TOOLS NEEDED CUTTING THE COUNTERTOP If you are installing the cooktop in a solid surface material such as granite quartz or any other natural or synthetic solid surface we recommend that the cutout be prepared by a professional cabinet or countertop installer Coo...

Page 2: ... you ELECTRICAL REQUIREMENTS This appliance must be supplied with the proper voltage and frequency and connected to an individual properly grounded branch circuit protected by a circuit breaker or a time delay fuse as noted on name plate and the chart below We recommend you have the electrical wiring and hookup of your cooktop connected by a qualified electrician After installation have the electr...

Page 3: ...ings countertop and cabinets around the cooktop can withstand heat up to 200 F generated by the cooktop H Installing cooktop in combination with other products Both products must be installed according to their specific product installation instructions Consideration must be given the separate electrical requirements and locations Over one or two wall ovens Only certain models may be installed ove...

Page 4: ... length of cut 1 3 4 MIN Between rear edge of cutout and the wall behind the cooktop 19 5 8 19 3 4 30 19 1 8 19 1 4 36 width of cut 2 1 2 MIN From front edge of cutout and front edge of countertop Size Models X Y Z Front Z Rear 30 JP3030D T JP3530D T 29 3 4 20 7 8 3 1 4 4 JP3030SJSS JP3530SJSS 29 7 8 21 3 1 4 4 CP9530D JP5030D PP7030D PP7030E 29 3 4 20 7 8 3 9 16 5 9 16 JP5030S PP7030S PP9030S 29 ...

Page 5: ...Americans with Disabilities Act ADA Forward Approach Installation Only NOTE The enclosure must be made of wood material Also an access panel is required for the junction box hold down brackets and service Wall covering cabinets and countertop must withstand heat up to 200 F 13 max Depth of unprotected overhead cabinets 30 min Clearance from countertop to unprotected overhead surface 30 min for 30 ...

Page 6: ... and ZEU36 models apply the foam tape around the outer edge of the glass on the sides and rear of the unit only 4 MOUNTING PARTS Remove the hold down brackets and screws from the literature package Screw the hold down bracket to the side of the cooktop unit Repeat for opposite side of cooktop 2 PROTECT SURFACE OF COOKTOP Place a towel or tablecloth onto the countertop Lay the cooktop upside down o...

Page 7: ... length of conduit provided The conduit must not be shortened B With the cooktop in place open the front of the cabinet door C Insert the wires from the conduit through the opening of the junction box D Connect the red and black leads from the cooktop conduit to the corresponding leads in the junction box Connect the ground wire E Once the connections are made secure wires together using wire nuts...

Page 8: ...ched or in contact with moving parts C Check level of appliance D Check that the cooktop is properly grounded NOTE TO ELECTRICIAN The power leads supplied with this appliance are UL recognized for connections to larger gauge household wiring The insulation of these leads is rated at temperatures much higher than the temperature rating of household wiring The current carrying capacity of a conducto...

Page 9: ...ecta es responsabilidad del instalador y el mal funcionamiento del producto debido a una instalación inadecuada NO está cubierto bajo la garantía NECESITARÁ LOS SIGUIENTES MATERIALES HERRAMIENTAS QUE PUEDE NECESITAR ABERTURA DE LA MESADA Si instalará la superficie de cocción en un material de superficie sólida tal como granito cuarzo o cualquier otra superficie sólida natural o sintética le recome...

Page 10: ...bicación REQUISITOS ELÉCTRICOS Este aparato debe contar con el voltaje y frecuencia adecuados y deberá conectarse a un circuito derivado individual debidamente descargado a tierra protegido por un cortacircuitos o un fusible temporizado como lo indica la placa y el cuadro más abajo Le recomendamos que un electricista calificado conecte el cableado eléctrico y conexión de su estufa Después de la in...

Page 11: ...cción en combinación con otros productos Ambos productos deben ser instalados de acuerdo con sus instrucciones de instalación específicas del producto Se deben tener en consideración los requisitos y ubicaciones eléctricas específicas Sobre uno o dos hornos de pared Sólo ciertos modelos pueden ser instalados sobre los hornos de pared El horno de pared y la superficie de cocción tendrán ambos una e...

Page 12: ...4 36 longitud del corte MÍNIMO de 1 entre el extremo trasero de la abertura y la pared detrás de la superficie de cocción 19 5 8 19 3 4 30 19 1 8 19 1 4 36 ancho del corte MÍNIMO de 2 1 2 desde el extremo frontal de la abertura y el extremo frontal de la mesada Profundidad en la parte trasera de la superficie de cocción en la ubicación del conducto Estufa X 30 modelos 19 1 4 36 modelos 18 7 8 Z Y ...

Page 13: ...uierdo de la unidad que esté por debajo de una altura de despeje mínimo de 15 Despeje mínimo de 15 desde la mesada hasta el lado inferior de los gabinetes más cercanos a ambos lados de la superficie de cocción incluyendo cualquier riel de luz Despeje mínimo de 1 30 y despeje mínimo de 2 36 desde la abertura hasta la pared vertical más cercana o el gabinete del lado derecho de la unidad que esté po...

Page 14: ...cinta de espuma alrededor del borde externo del vidrio en los lados y borde posterior de la unidad 4 LAS PARTES DE MONTAJE Saque las abrazaderas de montaje y tornillos del empaque con material impreso Atornille la abrazadera de montaje a un lado de la unidad de la estufa Repita en el lado opuesto de la estufa 2 PROTECCIÓN DE LA SUPERFICIE DE LA ESTUFA Coloque una toalla o mantel sobre el mostrador...

Page 15: ...ducto no debe reducirse B Con la estufa colocada en su lugar abra el frente de la puerta del gabinete C Inserte los cables del conducto a través de la abertura de la caja de conexiones D Conecte los cables rojo y negro del conductor de la estufa a los cables correspondientes en la caja de conexiones Conecte el cable a tierra E Una vez que se hayan realizado las conexiones fije los cables con las t...

Page 16: ...cto con partes móviles C Verifique el nivel del aparato D Verifique que la estufa esté descargada a tierra correctamente 2 LISTA DE VERIFICACIÓN DE OPERACIÓN A Retire todos los objetos que se encuentren sobre la superficie de la estufa A Encienda la toma de corriente de la estufa consulte su Manual del propietario Verifique que todas las hornillas de la superficie funcionen correctamente A Verifiq...