Programming the Panel
24
High Level Rpts (0101-cs phone 1, 0111-cs phone 2)
Phones-CS Phone 1-2 (Default: CS Phone
1=on, CS Phone 2=off)
When this setting is on, the panel reports to the central station events that
involve a high-level security risk, including the following conditions:
•
Fire, Police, Auxiliary, Duress, and Freeze alarms
•
No Activity
•
Receiver Failure (or jam)
•
System Tamper (40 incorrect keystrokes or touchpad supervisory),
•
Entering or exiting Sensor Test mode
Note
For UL 1635 listed installations, this feature must be set to on for the programmed
phone number.
¾
To turn High-Level Reports off or on:
1. With the display showing
HIGH LEVEL RPTS
OFF/ON
(current setting)
, press
1
(off) or
2
(on). The display flashes the entered setting.
2. Press
ƒ
and the display shows the new set-
ting.
Low Level Rpts (0102-cs phone 1, 0112-cs phone 2)
Phones-CS Phone 1-2 (Default: CS Phone
1=on, CS Phone 2=off)
When this setting is on, the panel reports non-alarm conditions to the central
station, including the following conditions:
•
Force Armed
•
Hardwire Zone Trouble (open or short)
•
Supervisory (wireless devices)
•
Low Battery (wireless devices)
•
Other non-alarm related conditions
Note
For UL 1635 listed installations, this feature must be set to on for the programmed
phone number.
¾
To turn Low-Level Reports off or on:
1. With the display showing
LOW LEVEL RPTS
OFF/ON
(current setting)
, press
1
(off) or
2
(on). The display flashes the entered setting.
2. Press
ƒ
and the display shows the new set-
ting.
Open/Close Rpts (0103-cs phone 1, 0113-cs phone 2)
Phones-CS Phone 1-2 (Default=off)
When this setting is on, the panel sends a report when the system is armed
(closed) or disarmed (opened).
Note
To use this feature, the Opening Reports and Closing Reports settings under the
REPORTING
menu must be turned on.
¾
To turn Opening/Closing Reports off or
on:
1. With the display showing
OPEN/CLOSE RPTS
OFF/ON
(current setting)
, press
1
(off) or
2
(on). The display flashes the entered setting.
2. Press
ƒ
and the display shows the new set-
ting.
Backup (0104-cs phone 1, 0114-cs phone 2)
Phones-CS Phone 1-2 (Default: CS Phone
1=on, CS Phone 2=off)
This setting determines whether or not the panel uses another programmed
central station phone number for reporting if three initial attempts are unsuc-
cessful.
CS Phone 1 is backed up by CS Phone 2, and CS Phone 2 is backed up by
CS Phone 1. The panel makes up to 16 attempts (8 per phone number), alter-
nating between the two programmed phone numbers.
For example, if Backup is on and three failed reporting attempts occur using
CS Phone 1, the panel switches to CS Phone 2 for three more reporting
attempts. If these attempts fail, the panel switches back to CS Phone 1 for
five more reporting attempts and, if necessary, switches back to CS Phone 2
for five final attempts.
¾
To turn Backup off or on:
1. With the display showing
BACKUP OFF/ON
(current setting)
, press
1
(off) or
2
(on).
The display flashes the entered setting.
2. Press
ƒ
and the display shows the new set-
ting.