Programming the Panel
21
The following describes how to program the security settings that appear under
PARTITION 1
.
Dealer Code (0002)
Security-Global (Default = none)
The 4-digit dealer code is used to prevent unau-
thorized persons from changing the programmed
central station phone numbers and the Down-
loader Access Code. When this feature is
enabled, central station phone numbers and the
Downloader Code cannot be changed (unless
you enter the program mode by using the dealer
code). All other system settings are still accessi-
ble by entering the program mode with the
installer code.
¾
To program a Dealer Code:
1. With the display showing
DEALER CODE ****
, enter the desired 4-digit
code. The display flashes the entered setting.
2. Press
ƒ
and the display shows the new code.
¾
To delete a Dealer Code:
1. With the display showing
DEALER CODE nnnn
(current code)
, press
D
.
The display shows
DEALER CODE ****
.
Note
The Dealer Code cannot be deleted by clearing panel memory.
SIA False Alarm Reduction (0003)
Security-Global (Default = on)
Controls the following settings that are required by the SIA False Alarm
Reduction Standard:
•
Arming level changes made from wireless touchpads and keychain
touchpads are sounded (beeps) on exterior siren output (on) OR are not
sounded on exterior siren output (off).
Note
The siren output must be configured for “Exterior Siren” (016xx) for the arming
level beeps to be annunciated.
•
The Arming Always Silent feature is disabled for users if this setting is
on OR can be controlled by users if the setting is off. Silent Arming on
Demand is not affected.
¾
To turn SIA False Alarm Reduction off or
on:
1. With the display showing
SIA FALSE ALARM
(current setting)
, press
1
(off) or
2
(on).
The display flashes the entered setting.
2. Press
ƒ
and the display shows the new set-
ting.
Account Number (0010)
Security-Partition 1 (Default = 00000)
The account number is used as panel (or customer) identification for the cen-
tral monitoring station. The panel sends the account number every time it
reports to the central station. Account numbers must be 1 to 10 characters
long.
Alpha characters A-F can be assigned to the account number by pressing and
holding buttons 1-6 respectively until the character appears.
¾
To program an Account Number:
1. With the display showing
ACCOUNT NUMBER
nnnnn
(current number)
, enter the desired
account number. The display flashes the
entered setting.
2. Press
ƒ
and the display shows the new num-
ber.
Quick Arm (0011)
Security-Partition 1 (Default = off)
Quick Arm allows system arming without using an access code. When this
feature is on, the system arming level can be increased from Level 1-OFF to
LEVEL 2-STAY, from Level 1-OFF to LEVEL 3-AWAY, or from Level 2-
STAY to LEVEL 3-AWAY without entering an access code. A valid access
code is still required to decrease the arming level or disarm the system.
¾
To turn Quick Arm off or on:
1. With the display showing
QUICK ARM OFF/
ON
(current setting)
, press
1
(off) or
2
(on). The display flashes the entered setting.
2. Press
ƒ
and the display shows the new set-
ting.