![background image](http://html1.mh-extra.com/html/ge/az45e07ea-series/az45e07ea-series_technical-service-manual_4683517016.webp)
– 16 –
AZ6500 Series ONLY
The outdoor fan and the compressor are turned ON at the same time. The indoor fan is turned on 3 seconds
before the compressor and outdoor fan is turned ON. The indoor fan is then turned OFF for 6 seconds after
the compressor and outdoor fan are turned OFF.
Fan Cycle - Heat Pump Mode
Fan Cycle - Heat Pump Mode
Temp. S0.9°F
Temperature
COMPRESSOR AND
OUTDOOR FAN
INDOOR FAN
ON
ON
ON
ON
6 sec
3 sec