Fan Cycle Operation
There are two Fan Cycle auxiliary settings. These modes are utilized to switch between a CONTINUOUS
setting, and the fan motor continues to operate even when the compressor or the electric heater cycles ON/
OFF. In the CYCLE setting, the indoor fan cycles ON/OFF with the heating and cooling functions.
When the Class 2 Mode is selected, the fan motor is controlled by the remote wall thermostat, independent
of positions of Fan Cycle auxiliary set button modes.
Fan Cycle - Cooling Mode
The indoor fan runs for a short period of time, approximately 3 seconds, before the compressor and outdoor
fan are turned on.
The indoor and outdoor fan runs continuously for a short period of time, approximately 30 seconds, after the
compressor and outdoor fan are turned OFF.
,QWKHFRROLQJPRGHWKHLQGRRUIDQLVGHVLJQHGWRRSHUDWHDWWZRGLȺHUHQWVSHHGV,IWKHFRQWUROKDSSHQVWR
be in the compressor restart delay (allowing the internal pressure to equalize before turning the compressor
21WKHLQGRRUIDQWXUQV21LQWKHQRUPDOVHTXHQFHDVVKRZQLQWKH¿JXUHEHORZ7KHRXWGRRUIDQDQG
compressor turn ON at the end of the restart delay.
In the Class 2 mode, the indoor fan shall be controlled directly by the remote thermostat.