background image

10

49-5000629   Rev. 0

WIFI SET UP

WiFi Setup

GE Appliances SmartHQ (for customers in the United States)

GE Appliances SmartHQ Enabled*.

If your Dehumidifier has a Connected Appliance Information label located 

on the outside as shown below, your dehumidifier is 

GE Appliances SmartHQ Enabled.

 A WiFi communication 

card is built into the product allowing it to communicate with your smart phone for remote monitoring, control and 
notifications. Please visit 

www.GEAppliances.com/connect 

to learn more about connected appliance features, and 

to learn what connected appliance apps will work with your smart phone.

WiFi Connectivity:

For assistance with the appliance 
or the 

ConnectPlus

 network 

connectivity (for models that are WiFi 
enabled or WiFi optional),
please call 

1-800-220-6899.

Network:  GE_MODULE_XXXX

PASSWORD:  XXXXXXXX

MAC ID:  XX-XX-XX-XX-XX-XX

CONTAINS FCCID:  2ALD3-MKQTWIFI11

CONTAINS IC: 

22987-MKQTWIFI11

Getting Started

7RFRQQHFW\RXUGHKXPLGL¿HU\RX¶OOQHHGWKH*(

Appliances App. The app will walk you through the 
connection process. Download the app from iTunes or 
Google Play. 

All connected appliace data is held in strict accordance 
with the GE Appliances Connected Data Privacy Policy. 
Visit 

geappliances.com/privacy/privacy_policy_

connected

 to view this policy. 

Questions about SmartHQ

Get answers you need about setting up WiFi appliances 
and connecting to your home network in our support 
articles. 

Visit 

products.geappliances.com/appliance/gea-

support-search-content 

to view wifi connect support 

articles.

REGULATORY INFORMATION

FCC/IC Compliance Statement:

This device complies with Part 15 of the FCC Rules. 
Operation is subject to the following two conditions:

1. This device may not cause harmful interference.

2. This device must accept any interference received, 

including interference that may cause undesired 
operation. 

This equipment has been tested and found to comply 
with the limits for a Class B digital device, pursuant to 
Part 15 of the FCC Rules. These limits are designed 
to provide reasonable protection against harmful 
interference in a residential installation. This equipment 
generates uses and can radiate radio frequency energy 
and, if not installed and used in accordance with the 
instructions, may cause harmful interference to radio 
communications. However, there is no guarantee that 
interference will not occur in a particular installation. If 
this equipment does cause harmful interference to radio 

or television reception, which can be determined by 
turning the equipment off and on, the user is encouraged 
to try to correct the interference by one or more of the 
following measures:

• Reorient or relocate the receiving antenna.

• Increase the separation between the equipment and 

receiver.

• Connect the equipment into an outlet on a circuit 

different from that to which the receiver is connected.

• Consult the dealer or an experienced radio/television 

technician for help.

Labelling:

 Changes or modifications to this unit not 

expressly approved by the manufacturer could void the 
user’s authority to operate the equipment. 

*Select Models Only

This product has Wi-Fi capability and requires 
Internet connectivity and a wireless router to enable 
interconnection with an Energy Management System, 
and/or with other external devices, systems or 
applications.

Summary of Contents for AWHR50

Page 1: ...ATING INSTRUCTIONS Controls 4 Other Features 5 How the Dehumidifier Operates 6 Automatic Defrost 6 Choosing a Location 6 Removing Collected Water 7 Water Level 7 Bucket Operation 7 CARE AND CLEANING Grille and Case 8 Water Bucket 8 Air Filter 8 TROUBLESHOOTING TIPS 9 WIFI SETUP 10 CONSUMER SUPPORT Limited Warranty 11 Consumer Support 12 ENGLISH ESPAÑOL Before you begin Record the GE module number ...

Page 2: ...es into every GE Appliances product and we think you will too Among other things registration of your appliance ensures that we can deliver important product information and warranty details when you need them Register your GE appliance now online Helpful websites and phone numbers are available in the Consumer Support section of this Owner s Manual You may also mail in the pre printed registratio...

Page 3: ...prior to product disposal If you are getting rid of an old product with refrigerants check with the company handling disposal about what to do Do not use outdoors This dehumidifier is intended for indoor residential applications only This dehumidifier should not be used for commercial or industrial applications These R410A Dehumidifier Systems require contractors and technicians to use tools equip...

Page 4: ...4 hours for the dehumidifier to achieve the humidity level If you still have damper air than desired set the humidity level to a lower setting or select Nonstop for maximum dehumidification 5 Filter Timer After 250 hours of operation the Clean the Filter indicator light will glow to remind you to clean the filter Remove the filter and clean it Press and hold Filter button for 3 seconds to reset th...

Page 5: ...ition NOTE The fan and compressor will stop running as soon as the bucket is removed The alarm will sound if the bucket is not replaced in the proper position after 3 minutes Auto Defrost When frost builds up on the evaporator coils the compressor will cycle off and the fan will continue to run until the frost disappears Power Outage In the case of a power outage or interruption the unit will auto...

Page 6: ...ehumidifier to prevent moisture damage anywhere books or valuables are stored Use the dehumidifier in a basement to help prevent moisture damage The dehumidifier must be operated in an enclosed area to be most effective Close all doors windows and other outside openings to the room NOTE The dehumidifier has casters to aid placement but it should only be rolled on smooth flat surfaces Do not attemp...

Page 7: ...mpty and replace the bucket IMPORTANT Do not use the hose if using the bucket to collect water When the hose is connected water will flow through it onto the floor instead of into the bucket NOTES Do not remove the bucket while the dehumidifier is operating or if it has just stopped operating This might cause some water to drip from the drain pan The bucket must be in place and securely seated for...

Page 8: ...hout a filter because dirt and lint will clog the unit and reduce performance Grille and Case To clean the case Use water and a mild detergent Do not use bleach or abrasives To clean the rear grille Use a vacuum attachment or brush Water Bucket To clean Every few weeks clean the bucket to prevent growth of mold mildew and bacteria Partially fill the bucket with clean water and add a little mild de...

Page 9: ...a lower percent value or at the Nonstop setting for maximum dehumidification Doors and windows may not be closed tightly Check that all doors windows and other openings are securely closed Clothes dryer may be blowing moisure laden air into the room Install the dehumidifier away from the dyer The dryer should be vented to the outside Room temperature is too low Moisture removal is best at higher r...

Page 10: ...FCC IC Compliance Statement This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference 2 This device must accept any interference received including interference that may cause undesired operation This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to P...

Page 11: ...for providing adequate electrical connecting facilities Ŷ DLOXUH RI WKH SURGXFW UHVXOWLQJ IURP PRGLILFDWLRQV to the product or due to unreasonable use including failure to provide reasonable and necessary maintenan e Ŷ 5HSODFHPHQW RI KRXVH IXVHV RU UHVHWWLQJ RI FLUFXLW breakers Ŷ DLOXUH GXH WR FRUURVLRQ RQ PRGHOV QRW FRUURVLRQ protected Ŷ DPDJH WR WKH SURGXFW FDXVHG E LPSURSHU SRZHU supply voltage...

Page 12: ...rranty expires In the US GEAppliances com extended warranty or call 800 626 2224 during normal business hours Remote Connectivity For assistance with wireless network connectivity for models with remote enable visit our website at GEAppliances com connect or call 800 220 6899 in the US Parts and Accessories Individuals qualified to service their own appliances can have parts or accessories sent di...

Page 13: ...s funciones 5 Cómo funciona el deshumedificador 6 Descongelado automático 6 Selección del lugar adecuad 6 Cómo desechar el agua acumulada 7 Nivel de agua 7 Funcionamiento del Balde 7 CUIDADO Y LIMPIEZA Rejilla y gabinete 8 Tanque de agua 8 Filtre de aire 8 CONSEJOS PARA LA SOLUCIÓN DE PROBLEMAS 9 CONFIGURACIÓN WIFI 10 AYUDA AL CLIENTE Garantía Limitada 11 Ayuda al cliente 12 Antes de comenzar Regi...

Page 14: ...s y creemos que usted también Entre otras cosas el registro de su electrodoméstico asegura que podamos entregarle información importante del producto y detalles de la garantía cuando los necesite Registre su electrodoméstico GE ahora a través de Internet Sitios Web y números telefónicos útiles están disponibles en la sección de Soporte para el Consumidor de este Manual del Propietario También pued...

Page 15: ...LRQHV UHVLGHQFLDOHV GH LQWHULRU 1R GHEH XVDUVH SDUD aplicaciones comerciales ni industriales Ŷ VWRV 6LVWHPDV HVKXPHGLILFDGRUHV 5 UHTXLHUHQ que los contratistas y técnicos utilicen herramientas equipamiento y normas de seguridad aprobadas para VX XVR FRQ HVWH UHIULJHUDQWH 12 XWLOLFH HTXLSDPLHQWR certificado sólo para refrigerante R22 Ŷ VWH HOHFWURGRPpVWLFR SXHGH VHU XVDGR SRU SHUVRQDV FRQ capacidad...

Page 16: ...alcance el nivel de humedad Si el aire aún está más húmedo de lo deseado ajuste el nivel de humedad a un nivel menor o seleccione el botón de IXQFLRQDPLHQWR FRQWLQXR 1RQVWRS SDUD REWHQHU XQD máxima deshumidificación 5 Temporizador del filtro Filter Timer HVSXpV GH KRUDV GH RSHUDFLyQ VH HQFHQGHUi OD OX LQGLFDGRUD GH OHDQ WKH LOWHU LPSLH D GH ILOWUR SDUD recordarle que debe limpiar el filtro Quite e...

Page 17: ...a si el interruptor del control del nivel de agua no es reiniciado NOTA El ventilador y el compresor dejarán de funcionar tan SURQWR FRPR VH UHWLUH HO EDOGH D DODUPD VRQDUi VL HO EDOGH no se vuelve a colocar en la posición correcta después de 3 minutos Descongelado automático AUTO DEFROST Cuando se acumule escarcha en los serpentines evaporadores el compresor se apagará y el ventilador continuará ...

Page 18: ...idenciales GH LQWHULRU 1R GHEH XVDUVH SDUD DSOLFDFLRQHV FRPHUFLDOHV ni industriales Ŷ Coloque el deshumedificador en un piso firme y nivelado que sea lo suficientemente fuerte para soportar la unidad cuando la cubeta esté llena de agua Ŷ HMH SRU OR PHQRV SXOJDGDV GH HVSDFLR OLEUH DOUHGHGRU de la unidad para que exista una buena circulación de aire Ŷ Coloque el deshumedificador en un área en la que...

Page 19: ...GDG 2 Abra la tapa de drenaje sobre el lado de 3 Enrosque una manguera de jardín no suministrada sobre la boquilla y asegúrese de que se encuentre bien ajustada Corte la misma de acuerdo a la longitud y condúzcala hasta el drenaje del piso 9XHOYD D FRORFDU HO WDQTXH HQ OD XQLGDG NOTA El tanque debe estar en su lugar y bien sujeto para que el deshumedificador funcione Siempre cerciórese de que la t...

Page 20: ... VLQ el filtro debido a que la suciedad y las pelusas lo obstruirán y reducirán su rendimiento Rejilla y gabinete Para limpiar el gabinete 8VH DJXD XQ GHWHUJHQWH GH EDMD FRQFHQWUDFLyQ 1R XVH blanqueador ni limpiadores abrasivos Para limpiar la rejilla superior o trasera 8VH XQD DVSLUDGRUD FRQ DFFHVRULR GH FHSLOOR VXDYH o un cepillo de mano Tanque de agua Para limpiar Después de algunas semanas lim...

Page 21: ...QVWRS SDUD obtener una máxima deshumidificación Las puertas y ventanas no están cerradas completamente Revise que todas las puertas ventanas y otras aberturas están cerradas completamente El secador de ropa podría estar generando aire húmedo en el recinto Instale el deshumedificador lejos de la secadora de ropa El secador debe desechar el aire hacia el exterior La temperatura del recinto está dema...

Page 22: ...alación en particular Si este equipo provoca interferencias perjudiciales para la recepción de radio o televisión lo que puede comprobar encendiendo y apagando el equipo se aconseja al usuario que intente corregir la interferencia a través de una o más de las siguientes medidas Reoriente o reubique la antena receptora Aumente la separación entre el equipo y el receptor Conecte el equipo a un tomac...

Page 23: ...capacidad adecuada contacte a su vendedor minorista o instalador Usted es responsable de brindar instalaciones de conexión eléctrica adecuadas Ŷ DOOD GHO SURGXFWR FRPR UHVXOWDGR GH PRGLILFDFLRQHV VREUH el mismo o debido a un uso irrazonable incluyendo la falta de mantenimiento razonable o necesario Ŷ 5HHPSOD R GH IXVLEOHV GHO KRJDU R UHLQLFLR GH GLV XQWRUHV Ŷ DOODV FRPR FRQVHFXHQFLD GH FRUURVLyQ Ŷ...

Page 24: ... D Q HVWDUiQ DOOt FXDQGR VX JDUDQWtD FDGXTXH Q 88 GEAppliances com extended warranty R OODPH DO GXUDQWH el horario comercial habitual Conectividad Remota Para solicitar asistencia con la conectividad de red inalámbrica para modelos con activación remota visite nuestro sitio Web en GEAppliances com connect R OODPH DO HQ 88 Piezas y Accesorios Individuos calificados para realizar el servicio técnico...

Reviews: