AV-300i Version 2 User’s Guide
—————— Function Description ——————
Ch.1
131
1.12.8 Fault Pin
The state of those alarms having an activity different from Ignore and Only msg alarmq is stated on this variable.
No active alarm
=>
0x0000
One active alarm
=>
Number of the corresponding pin
Several active alarms
=>
Last intervened alarm
Reset alarms
=>
Last intervened alarm. Set with 0x0000 the
“alarm Reset” command.
The variable can be read via the serial line, field bus and Dgfc.
ALARM Name
Bit position in the alarm Word
Code in the alarm LIST
Failure supply
1
21
Undervoltage
2
22
Overvoltage
3
23
IGBT desaturat
4
24
Inst overcurrent
5
25
Ground fault
6
26
Curr fbk loss
7
27
External fault
8
28
Spd fbk loss
9
29
Module OT
10
30
Heatsink OT
11
31
Motor OT
12
32
Heatsink S OT
13
33
Regulation S OT
14
34
Intake Air S OT
15
35
ISBus fault
16
36
Comm card fault
17
37
Appl card fault
18
38
Drv overload
19
39
Mot overload
20
40
BU overload
21
41
Data lost
22
42
Fwd Rev Ctrl
23
43
Max time
24
44
Sequencer
25
45
PLS timeout
26
46
Overspeed
27
47
UV repetitive
28
48
IOC repetitive
29
49
IGBTdesat repet
30
50
WatchDog user
31
51
Hw fail
32
52
Fault pin table
Table 1.12.8.1: Fault Pin List
Summary of Contents for AV-300i
Page 1: ...GEH 6641E Supersedes GEH 6641D GE Industrial Systems AV 300i TM Version 2 User s Guide ...
Page 2: ......
Page 12: ...GEH 6641E TABLE OF CONTENTS 12 ...
Page 44: ...GEH 6641E Function Description 44 Ch 1 ...
Page 174: ...GEH 6641E Function Description 174 Ch 1 ...
Page 295: ......