GEH-6641E
—————— Function Description ——————
104
Ch.1
N
OTES
!
The selection of base value must be done prior to assigning thresholds and bands. After any
change of SPG base value, gains must be reassigned.
Values assigned to thresholds and bands must be in ascending order.
The value assigned to parameter [SGP tran21 h thr] must be higher then parameter [SGP
tran 32 I thr] . Bands must be narrower then half the distance between [SGP tran21 h thr]
and [SGP tran 32 I thr].
When the motor is stopped, the gain of the Speed Regulator is set by the Speed 0 P gain and
Speed 0 I gain, if the speed 0 function is enabled.
The Block input is:
· SGP ref src
The outputs are:
· SGP ref mon
· In use SpeedP gain%
· In use SpeedI gain%
Description:
SPEED CONFIG Spd gain profile
SGP src
SGP ref src
SGP cfg
SpdP1 gain %
SpdI1 gain %
SpdP2 gain %
SpdI2 gain %
SpdP3 gain %
SpdI3 gain %
SGP tran21 h thr
SGP tran32 l thr
SGP tran21 band
SGP tran32 band
Int SGP ref
SGP base value
SGP mon
SGP ref mon
InUse SpdP gain%
InUse SpdI gain%
SPEED CONFIG SAVE PARAMETERS