AV-300i Version 2 User’s Guide
—————— Function Description ——————
Ch.1
105
The Gain Adaptive Block is shown in the figure below.
.
.
.
.
Ref
Ref
SGP ref src
Int SGP ref
Int SGP ref
0 cnt
SpdI2 gain %
10 %
SpdP2 gain %
10 %
SGP tran32 l thr
0 %
SGP tran21 h thr
0 %
SGP tran32 band
0 %
SGP tran21 band
0 %
InUse SpdP gain%
InUse SpdI gain%
SGP base value
16384 cnt
SGP ref mon
SpdP3 gain %
10 %
SpdP1 gain %
10 %
SpdI1 gain %
10 %
SpdI3 gain %
10 %
Spd gain profile src
SGP ref src
Source selection of the adaptive x axis
Spd gain profile cfg
SpdP1 gain %
Proportional Gain
1° segment
SpdI1 gain %
Integral Gain
1° segment
SpdP2 gain %
Proportional Gain
2° segment
SpdI2 gain %
Integral Gain
2°segment
SpdP3 gain %
Proportional Gain
3° segment
SpdI3 gain %
Integral Gain
3° segment
SGP tran21 h thr
Segment transition point from 1 to 2
SGP tran32 l thr
Segment transition point from 2 to 3
SGP tran21 band
Width of the transition band from 1 to 2
SGP tran32 band
Width of the transition band from 2 to 3
Int SGP ref
SGP internal reference
SGP base value
Basic value corresponding to 100% of the SGP Reference
Spd gain profile mon
SGP ref mon
SGP Reference Monitor
InUse SpdP gain%
Value of the proportional gain in use
InUse SpdI gain%
Value of the integral gain in use