PREPARE AIR CONDITIONER

Remove the backing from the top
mounting rail seal strip and attach it 
to the bottom of the top mounting rail. 
Cut to size.

Install the top mounting rail with 3 or 4
type A screws (depending on the number
of holes in the top mounting rail) from the
outside of the case. 

Loosen the lower screw on each side of 
the case and hook a security bracket on
each side. To allow for later adjustment, 
do not tighten the screws until you install
the unit in the window. 

3

A

B

Top mounting
rail

Bottom
mounting rail

C

Security
bracket

Security
bracket

Installation Instructions

WINDOW REQUIREMENTS

• 

These instructions are for a standard double-
hung window. You will need to modify them for
other types of windows.

• 

All supporting parts must be secured to firm
wood, masonry or metal.

• 

The electrical outlet must be within reach of the
power cord.

1

STORM WINDOW REQUIREMENTS

A storm window frame will not allow the air
conditioner to tilt toward the outside, and will
keep it from draining properly. To adjust for this,
attach a piece of wood to the stool.

WOOD PIECES–
WIDTH: 2

LENGTH: 

Long enough to fit inside the window

frame.

THICKNESS: 

To determine the thickness, place a

piece of wood on the stool to make it 1/2

higher

than the top of the storm window frame or the
vinyl frame.
Attach securely with nails or screws provided by
the installer.

2

11

13

min.

22

to 

36

(With accordion panels)

Models AST05, ASW05, ASH06 and ASW06 only

(See below illustration for Models ASH08 and ASW08.)

Models ASH08 and ASW08 only

(See above illustration for Models AST05, ASW05, ASH06 and ASW06.)

13

1

2

min.

24

1

2

to 

36

(With accordion panels)

1/2

″ 

higher

than storm
window
frame

Storm window
frame

Wood

Stool

1/2

″ 

higher

than vinyl frame 
(on some windows)

Vinyl frame

Summary of Contents for ASW05

Page 1: ...Troubleshooting Tips 13 Normal Operating Sounds 13 Consumer Support Consumer Support 16 Warranty 15 DB98 26673A 49 7551 1 12 06 JR AST05 ASW05 ASH06 ASW06 ASH08 ASW08 Air Conditioners Owner s Manual...

Page 2: ...hich under federal law must be removed prior to product disposal If you are getting rid of an old product with refrigerants check with the company handling disposal about what to do SAFETY PRECAUTIONS...

Page 3: ...if you must use an extension cord it is absolutely necessary that it be a UL listed 14 gauge 3 wire grounding type appliance extension cord having a grounding type plug and outlet and that the electr...

Page 4: ...Energy Saver Controls the fan On The fan and compressor cycle on and off This results in wider variations of room temperature and humidity Normally used when the room is unoccupied Note The fan will...

Page 5: ...Cool mode and High 3 or Med 2 fan with a middle set temperature For Maximum Cooling Select the Cool mode and High 3 fan with a lower set temperature For Quieter Nighttime Cooling Select the Cool mode...

Page 6: ...the smaller blue area NOTE If you move the Mode Temp control knob from a Cool setting to the Fan On setting wait at least 3 minutes before switching back to a Cool setting Consumer Support Troubleshoo...

Page 7: ...en set at CLOSE only the air inside the room will be circulated and conditioned When set at OPEN some inside air is exhausted outside Vent Control on some models To open the vent push the lever to the...

Page 8: ...ove the plug from the wall outlet before cleaning To clean use water and a mild detergent Do not use bleach or abrasives Care and cleaning of the air conditioner 8 Consumer Support Troubleshooting Tip...

Page 9: ...re to leave these instructions with the Consumer Note to Consumer Keep these instructions for future reference Skill level Installation of this appliance requires basic mechanical skills Completion ti...

Page 10: ...CLUDED appearance may vary Type A 9 or 10 1 2 screws Security bracket 3 Type B 7 3 4 screws Top mounting rail Right accordion panel Foam top window gasket Window sash seal Left accordion panel Air con...

Page 11: ...ood masonry or metal The electrical outlet must be within reach of the power cord 1 STORM WINDOW REQUIREMENTS A storm window frame will not allow the air conditioner to tilt toward the outside and wil...

Page 12: ...op mounting rail Accordion panels Installation Instructions 4 A Window sash seal B INSTALL AIR CONDITIONER IN WINDOW CONT Extend the left and right accordion panels to the vertical window sashes and a...

Page 13: ...an the filter at least every 30 days See the Operating Instructions section The room may have been hot When the air conditioner is first turned on you need to allow time for the room to cool down Cold...

Page 14: ...14 Consumer Support Troubleshooting Tips Operating Instructions Safety Instructions Installation Instructions Notes...

Page 15: ...any succeeding owner for products purchased for home use within the USA Some states do not allow the exclusion or limitation of incidental or consequential damages This warranty gives you specific leg...

Page 16: ...bilities check out our Website today For the hearing impaired please call 800 TDD GEAC 800 833 4322 Parts and Accessories ge com Individuals qualified to service their own appliances can have parts or...

Page 17: ...talaci n en una ventana 9 12 Ideas para la identificaci n y reparaci n de problemas 13 Sonidos normales de operaci n 14 Apoyo al consumidor Apoyo al consumidor 16 Garant a 15 AST05 ASW05 ASH06 ASW06 A...

Page 18: ...ser removidos antes de desecharlos Si usted planea deshacerse de alg n producto que contenga refrigerantes p ngase en contacto con la compa a que se encarga de recoger su basura para que le indiquen q...

Page 19: ...esidad de usar un cable el ctrico de extensi n es absolutamente necesario que el mismo est listado bajo UL calibre 14 de tipo 3 tomas con conexi n a tierra para electrodom sticos y el ndice debe ser d...

Page 20: ...cupada Nota El ventilador continuar funcionando por un corto tiempo despu s de que el compresor haya entrado en el ciclo de apagado Off Apagado El ventilador funciona todo el tiempo mientras que el co...

Page 21: ...algunos modelos La direcci n de lado a lado del aire es ajustada por las palancas de las persianas Controles adicionales e informaci n importante No use en las condiciones externas debajo el punto de...

Page 22: ...friamiento normal Seleccione un modo Cool Enfriado con el bot n Mode Temp en la posici n del centro Para enfriamiento m ximo Seleccione un modo Cool Enfriado con el bot n Mode Temp apuntando hacia el...

Page 23: ...lado a lado es ajustada por las palanquitas en las parrillas Servicio al consumidor Solucionar problemas Operaci n Seguridad Instalaci n Para abrir la parrilla empuje la palanca hacia la derecha y pa...

Page 24: ...gue el acondicionador de aire y retire el enchufe del tomacorriente de la pared antes de limpiar Para limpiar use agua y un detergente suave No use cloro o materiales abrasivos Cuidado y limpieza del...

Page 25: ...za la posibilidad de descargas el ctricas Si el tomacorriente de la pared que usted planea usar solamente tiene 2 tomas es su responsabilidad hacer que un t cnico lo reemplace por uno de tres tomas co...

Page 26: ...o B 7 Riel de montaje superior Panel de acorde n derecho Parte superior de la espuma de la junta de la ventana Banda de sello de la ventana Panel de acorde n izquierdo Acondicionador de aire Cinta de...

Page 27: ...tornillos provistos por el instalador 2 PREPARE EL ACONDICIONADOR DE AIRE Retire la parte posterior la cinta de sellado del riel de montaje y adhi ralo al fondo del riel de montaje superior Corte al t...

Page 28: ...je superior Paneles de acorde n Instrucciones para la instalaci n 4 A Sello de la banda de ventana B INSTALE EL ACONDICIONADOR DE AIRE EN LA VENTANA CONT Extienda los paneles de acorde n izquierdo y d...

Page 29: ...que los registros de la calefacci n no est n abiertos y se encuentran retornando el aire fr o Coloque la ventanilla del acondicionador de aire en la posici n cerrada Las bobinas de enfriamiento Ver Ac...

Page 30: ...as lluviosos o cuando la humedad es alta Esta caracter stica de dise o ayuda a remover la humedad y mejora la eficiencia Quiz s escuche que el termostato hace clic cuando el compresor hace ciclo entr...

Page 31: ...or original y cualquier comprador posterior de productos comprados para uso residencial dentro de Estados Unidos Algunos estados no permiten la exclusi n o las limitaciones de da os incidentales o con...

Page 32: ...con dificultades auditivas favor de llamar al 800 TDD GEAC 800 833 4322 Piezas y accesorios ge com Aquellos individuos con la calificaci n necesaria para reparar sus propios electrodom sticos pueden...

Reviews: