background image

3.3.2 Using Custom 

AC Inputs

3.3.1 Connect the Driver Input

CLICK!

AC line

To driver input

Connect the yellow/green wire to 

the incoming ground conductor. 

Connect the brown wire to Line 1 

and blue wires to Neutral or Line 2 

of the incoming AC line.

>PA<

Pin

Line-to-Line 

Voltage

Line-to-Neutral 

Voltage

1

L2

L1

L1

L1

L2

L3

2

L3

L2

L3

N

N

N

PE

PE

PE

PE

PE

PE

PE

L=Line / N=Neutral / PE=Protective Earth

3.3.3 Connect Bead to 

AC Input Leader Cable

Connect 2 beads provided, the 

first bead should be no more than 

20 mm from input connector.

20mm

9

Installation Guide

Arize Factor

1

2

3

7

If you choose to use your own 

custom AC input connection, use a 

Wieland RST20i3 green connector 

(96.031.4055.7 OR 96.031.4155.7 OR 

96.031.0055.7 OR 96.031.1055.7) 

and plug into the male AC 

connector of the driver.

3.3.4 Connecting Driver 

to AC Line

NOTE:

 

To disassemble connectors, 

insert and twist a small blade 

screwdriver and then separate 

connectors.

Align keying features on driver with 

connector on the selected leader 

cable. 

Push connectors together until a 

click is heard.

Secure AC input leader cable, away 

from driver and light module.

Connector pin-out

1

2

PE

Summary of Contents for Arize Factor HORT171

Page 1: ...informacje dotycz ce bezpiecze stwa Nale y si z nimi dok adnie zapozna przed przyst pieniem do instalacji produktu PT As chamadas de aten o e as informa es relativas seguran a encontram se na ltima p...

Page 2: ...kg 5 72 lbs 2 319W GEHF HBRVW1 ML900 BRV 2 6 kg 5 72 lbs 2 316W GEHF MPKRW1 ML300 PKR 2 6 kg 5 72 lbs 4 5 or 6 104W GEHF MPKBW1 ML300 PKB 2 6 kg 5 72 lbs 4 5 or 6 104W GEHF MPKFW1 ML300 PKF 2 6 kg 5 7...

Page 3: ...8 in Extension Cable 0 59 kg 1 3 lbs Universal Cable Mount Product Code Detailed Description Weight 93153270 457 mm 18 in universal cable 0 04 kg 0 09 lbs 93154044 610 mm 24 in universal cable 0 05 kg...

Page 4: ...can be suspended on a support structure A or on cables as shown above B and C Attach wireform supports by pushing up into the slots on the underside of the lightbar Wireform supports Cross section vie...

Page 5: ...free upright ensure hooks on both sides are correctly engaged Ensure first end of bracket hook is lined up with oval mounting hole of driver Repeat on opposite driver mounting hole Standard hanger br...

Page 6: ...h Offset Hanger SNAP Offset hanger used with the standard hanger bracket to clear the bottom of the 41 mm Unistrut Standard bracket Offset hanger 41 mm Unistrut 2 3 Installation with Universal Cables...

Page 7: ...er cable Shorting cap Lightbar 1 ML 300 Electrical Connection 4 to 8 Lightbars only DC adapter cable 93118693 93067609 93067610 8 n 4 to 8 5 6 Shorting cap Optional inter connection cable Driver Drive...

Page 8: ...ssemble connectors turn locking ring 1 8 of a turn counter clockwise and separate connectors Connect other end of cable to the first lightbar or extension cable Be sure to tighten collar NOTE Use 900...

Page 9: ...first bead should be no more than 20mm from input connector 20mm 9 Installation Guide Arize Factor 1 2 3 7 If you choose to use your own custom AC input connection use a Wieland RST20i3 green connecto...

Page 10: ...Driver N 3 Y REPEAT FOR ENTIRE CIRCUIT BALANCING OUT EACH PHASE 3 L3 L2 L1 Driver Driver G G G G G G L L L L L L N N N N N N 8 6 7 Lightbar 1 5 WARNING Ambient temperature surrounding each driver must...

Page 11: ...brug Emballagematerialet kan genbruges Bortskaffe emballagen p en milj venlig m de og g r det tilg ngeligt for indsamlingstjenesten for genanvendeligt materiale FI VAROITUS S HK ISKUN RISKI Katkaise v...

Page 12: ...laggio riciclabile Smaltire l imballaggio in modo ecologico e renderlo disponibile per il servizio di raccolta del materiale riciclabile LT SP JIMAS ELEKTROS OKO PAVOJUS I junkite maitinim prie ap i r...

Page 13: ...ST PUJE ZAGRO ENIE PO AROWE Nale y przestrzega wszystkich norm IEC oraz lokalnych przepis w budowlanych Do po cze wej cia i wyj cia nale y stosowa wy cznie przewody z atestem IEC Minimalna powierzchni...

Page 14: ...lebilir malzeme toplama hizmeti i in kullan labilir hale getirin SV VARNING RISK F R ELEKTRISKA ST TAR St ng av f re inspektion installation och borttagning Jorda den elektriska enheten korrekt BRAND...

Page 15: ...ur local authorities or stockist for advice on recycling The packaging material is recyclable Dispose of the packaging in an environmentally friendly manner and make it available for the recyclable ma...

Reviews: