– 41 –
Control Diagnostics
Enter the diagnostic mode by pressing both the freezer temperature (COLDER and WARMER)
pads and the refrigerator temperature (COLDER and WARMER) pads simultaneously. All four pads
must be held for approximately 3 seconds. Blinking “0”s in both displays indicate the refrigerator
has entered the test mode.
Troubleshooting
Enter the appropriate display numbers
as shown below and press any pad other
than the temperature pads to activate
that test mode. Not all test modes are
available on all models.
Comments
Test can be
made with door
open.
See Note 1.
See Note 3.
Diagnostics
Communication check between
Temperature Control and Main
Control
Communication check between
Dispenser Control and Main Control
Temperature Control LED Test
Control and Sensor System Test
Duct Door Test
Results
P on freezer
display if OK. F if
problem is found.
P on freezer
display if OK. F if
problem is found.
All LEDs light.
Pressing the
corresponding pad
turns off the LED.
Checks each
thermistor and
displays P for pass
and 0 for fail.
Opens dispenser
duct door for 10
secs, then closes.
Fresh
Food
Display
2
4
6
7
8
0
0
0
0
0
Freezer
Display