– 29 –
Testing the 3-Way Valve
The valve returns to “home” at the end of every
freezer defrost cycle and whenever the refrig-
erator is reconnected to power.
To test the valve, disconnect the refrigerator
from power for at least 10 seconds, place a fi
nger on top of the valve and reconnect power.
The main control overdrives the valve to the
“home” position.
You should be able to feel the valve move as it
returns to the home position .
If movement is present, the main board and
valve coil are operating correctly.
Parts Needed:
• 3-Way Valve (part # WR57X10053)
• Thermal Paste (part # WX5X8927)
• Drier Assembly (part # WR86X93)
• Process valve (part # WJ56X61)
When replacing a 3-way valve, note the black
mark on the freezer outlet tube. Make certain to
mark the freezer capillary by placing a piece of
tape on the capillary, 6-8 inches from the valve.
This will aid in installing the capillaries in the
correct outlet tubes.
Replacing the 3-Way Valve
Black Mark
FREEZER
OUTLET
FRESH FOOD
OUTLET
INLET
Summary of Contents for Arctica G LINE PHG25PGT Series
Page 43: ...43 Schematic...