– 28 –
3-Way Valve Body
• The valve body contains a cam, rotor
and magnet.
• The rotor and cam are grooved to
rotate with the magnet.
• The entire valve body has refrigerant fl
owing through it when the compressor
is operating.
• Use care not to damage the top of the
valve body when installing the coil on
the valve.
• A locating pin is used to correctly align
the valve body in the valve coil.
• Failure to fully seat the valve in the coil
or to align it correctly with the pin can
cause the system to stop cooling.
Note: The 3-way valve comes only as a com-
plete assembly. Exploded view is for reference
only
.
Valve Rotation
• The pulses of the valve coil cause the magnet
to rotate inside the valve body.
• As the magnet rotates, it moves the cam at
the bottom of the valve.
The cam opens or covers the ports to the
capillary tubes.
Valve Body
Rotor
Cam
Magnet
Magnet
Stop Point
(Home Position)
CAPILLARY
TUBE
PORTS
Summary of Contents for Arctica G LINE PHG25PGT Series
Page 43: ...43 Schematic...