Chapter 2. Clamp-On Fixture and Transducer Installation
20
AquaTrans™ AT600 User’s Manual
2.2 Installing a CF-ES Clamp-On Fixture and Transducer System
To use the AT600 flow meter on 0.5 to 2 in. (15 to 50 mm) pipes, the
CF-ES
clamp-on fixture must be used.
UTXDR
or
CF-LP
transducers are available for installation in this fixture. Note the following specifications:
•
UTXDR
Transducer: Use cable adapter p/n 704-1678-LF with the AT6 transducer cable,
-40 to +120°C (-40 to +248°F) Temperatures, 4 MHz Frequency
•
CF-LP
Transducer: Use cable adapter p/n 210-410-LF with the AT6 transducer cable,
up to 230°C (446°F) Temperatures, 4 MHz Frequency.
Detailed installation instructions for this fixture and transducer are available in BHGE document #916-082.
2.3 Installing a General Clamping Fixture and Transducer System
Both the
C-RS
and
C-PT
transducers are mounted on the pipe with the BHGE
General Clamping Fixture
(
GCF
).
For detailed installation instructions refer to following:
•
C-RS Transducer Installation Guide (BHGE document #916-077)
•
C-PT Transducer Installation Guide (BHGE document #916-074)
2.3.1 Installing C-RS or C-PT Transducers with an RG316 Cable
The standard AT6 transducer cable is an RG316 cable with an
SMA
connector on the transducer end. To
connect the
BNC
connector on the C-RS or C-PT transducer to the SMA connector on the AT6 transducer
cable, a
BNC to SMA Adapter
is needed. See
below and install the cable adapter on the transducer
end of your AT6 cable.
Figure 22: BNC to SMA Cable Adapter Installation
Transducer
BNC to SMA Adapter
AT6 Cable with SMA Plug
with BNC Connector
Summary of Contents for AquaTrans AT600
Page 1: ...Flow 910 312 Rev D September 2017 bhge com AquaTrans AT600 User s Manual ...
Page 2: ......
Page 4: ... no content intended for this page ...
Page 12: ...Preface x AquaTrans AT600 User s Manual no content intended for this page ...
Page 34: ...Chapter 2 Clamp On Fixture and Transducer Installation 22 AquaTrans AT600 User s Manual ...
Page 107: ...AquaTrans AT600 User s Manual 95 Chapter 5 Error Codes and Troubleshooting ...
Page 108: ...Chapter 5 Error Codes and Troubleshooting 96 AquaTrans AT600 User s Manual ...
Page 183: ...AquaTrans AT600 User s Manual 171 Chapter 6 Communication ...
Page 184: ...Chapter 6 Communication 172 AquaTrans AT600 User s Manual ...
Page 190: ...Appendix A Specifications 178 AquaTrans AT600 User s Manual no content intended for this page ...
Page 194: ...Appendix B Data Records 182 AquaTrans AT600 User s Manual no content intended for this page ...
Page 212: ... no content intended for this page ...
Page 214: ... no content intended for this page ...
Page 215: ......