When necessary, the hood may be installed so that it is
supported by the soffit.
• The soffit should be constructed with 2 x 4’s.
• Determine the installation location.
• Continue the centerline forward on the bottom of the

cabinet or soffit.

Alternate Mounting Method

INSTALL HOOD TO SOFFIT OR

BENEATH CABINETS

Installation Instructions

15

4

IMPORTANT: Framing must be capable of

supporting 100 lbs (45.3 kg)

• Mounting screws must be secured to 2 x 4 studs 

(Dim. “A”) at locations shown in the above chart.

• Allow minimum opening (Dim. “B”) to accommodate

the duct transition in the soffit.

Cut a 10¾” x 8-7/16” hole through bottom of soffit or cabinet
for duct transition as shown.

B

A

A

C

2-3/8"

8-7/16"

5-3/8"

5-3/8"

Rear Wall

1 Ft = 0.3 m

1” = 2.5 cm

7-1/16"

14-1/2"

C

14-1/2"

12"

29-7/8"

2-9/16"

2-1/4"

2-3/8"

8-7/16"

10-3/4"

IMPORTANT: For additional support and to minimize
vibration during operation, we strongly recommend that
the hood also be secured to the back wall with wall
fasteners.

Top View, Front Side

30” Models

• Drill four 1/8” pilot holes in locations shown.
– If mounting to the underside of a cabinet with a

recessed bottom, install shims to fill the gap.

SKIP THIS STEP IF USING WALL MOUNTING

METHOD

“A”

“B”

Centerline to

Opening

Center of Stud

For Ductwork

30” Models

14½”

10¾”W x 8-7/16”D

36” Models

17½”

10¾”W x 8-7/16”D

Top View, Front Side

7-1/16"

17-1/2"

C

17-1/2"

12"

35-7/8"

2-9/16"

2-1/4"

2-3/8"

8-7/16"

10-3/4"

Top View, Front Side

36” Models

• Drive mounting screws into the studs until they

protrude ¼”. This ¼” gap will provide clearance to
engage the keyhole slots in the top of the hood.

• Lift hood onto mounting screws. Slide back against

the rear wall.

• Pull house wiring through the knockout at the rear or

the top of the hood.

• Tighten mounting screws.

Transition

Cabinet or

Soffit

¼” Gap

Add Shims
If Bottom Is
Recessed

Back Wall

Engage Keyhole
Slots and Push
Back to Wall

Summary of Contents for Appliances CV936

Page 1: ...5 Stainless Steel Surfaces 5 Installation Instructions 7 18 Troubleshooting Tips 20 Consumer Support Consumer Support Back Cover Product Registration 21 22 Warranty 23 Write the model and serial numbe...

Page 2: ...o properly exhaust air be sure to duct air outside Do not vent exhaust air into spaces within walls or ceilings or into attics crawl spaces or garages WARNING TO REDUCE THE RISK OF INJURY TO PERSONS I...

Page 3: ...LLOWING A Installation work and electrical wiring must be done by qualified person s in accordance with all applicable codes and standards including fire rated construction B Sufficient air is needed...

Page 4: ...humid It also reduces cooking odors and soiling moisture that create a frequent need for cleaning NOTE When the fan is operating on the LO setting it will be very quiet Always make sure that the fan i...

Page 5: ...ilters To clean the hood surface use a hot damp cloth with a mild detergent suitable for painted surfaces Use a clean hot damp cloth to remove soap Dry with a dry clean cloth Do not use steel wool pad...

Page 6: ...amp cloth To remove Turn the glass cover counterclockwise until the glass cover clears the socket Using gloves or a dry cloth remove the bulb by pulling it straight out To replace Use a new 12 volt 20...

Page 7: ...oper installation is not covered under the Warranty 18 21 35 7 8 12 18 21 29 7 8 12 PRODUCT DIMENSIONS WARNING Before beginning the installation switch power off at service panel and lock the service...

Page 8: ...ecorative duct cover is available to accommodate 8 to 10 ft ceiling heights The duct cover will expand from 12 Min or 24 to 34 Max height The duct cover conceals the ductwork running from the top of t...

Page 9: ...ecorative duct cover is available to fit both model widths The duct cover conceals the ductwork running from the top of the hood to the ceiling or soffit The duct cover will fit 8 ft to 10 ft ceiling...

Page 10: ...s horizontal ducting from the top of the hood through the backwall and You have an 8 ft ceiling and need to use a JXCH Series Chimney Cover or You have a 12 cabinet or 12 soffit that the hood is to be...

Page 11: ...vers Electric drill with 1 8 and 3 8 bits cUL Listed Wire nuts Hammer Safety glasses Metal snips Flashlight Pliers Wire Cutter Stripper Saber saw or Key Hole Saw Ladder Allen Wrench Remove transition...

Page 12: ...cover to conceal duct work running from the top of the hood to the ceiling The duct cover accessory consists of 2 pieces The outside piece is 12 high the inside piece is 22 Nested together they are 2...

Page 13: ...R DUCTING THROUGH REAR WALL Measure the supplied duct transition with any straight run length of duct used plus 90 elbow height Draw a horizontal line on the wall intersecting the centerline Wood Supp...

Page 14: ...ion to hood with 4 screws provided Use duct tape to seal the connection Remove Shipping Tape on Damper Duct Transition Top of Hood 24 to 36 INSTALL HOOD ONTO WALL 3 Lift the hood and place over the wo...

Page 15: ...support and to minimize vibration during operation we strongly recommend that the hood also be secured to the back wall with wall fasteners Top View Front Side 30 Models Drill four 1 8 pilot holes in...

Page 16: ...od screws and washers Use wall anchors if needed Note Bracket has 2 sets of holes Use larger holes for wall fasteners or wood screws with washers Use smaller holes for wood screws with washers INSTALL...

Page 17: ...the motor to attachment bracket at the front of the opening with washer and screw provided Plug the motor connector into the mating hood connector See the illustration for the hood connector location...

Page 18: ...filter support To remove the filters grasp the handle push the filter up and pull forward 18 Junction Box C Clip Filters Filter Support Place the filter drip trays into the horizontal channel in the f...

Page 19: ...19 Notes www GEAppliances ca Consumer Support Troubleshooting Tips Operating Instructions Safety Instructions Care and Cleaning...

Page 20: ...connector is loose Disconnect power to the unit Remove the filters or not plugged into its mating and look up at the blower If the blower connector connector plug is loose or you see the connector dan...

Page 21: ...ERSHIP REGISTRATION P O BOX 1780 MISSISSAUGA ONTARIO L4Y 4G1 FOR CANADIAN CONSUMERS ONLY POUR R SIDENTS CANADIENS SEULEMENT Please place in envelope and mail to Veuillez mettre dans une enveloppe et e...

Page 22: ...O NO RUE STREET NAME RUE APT NO APP RR CITY VILLE PROVINCE AREA CODE IND R G TELEPHONE T L PHONE E MAIL COURRIEL DID YOU PURCHASE A SERVICE CONTRACT FOR THIS APPLIANCE AVEZ VOUS ACHET UN CONTRAT DE SE...

Page 23: ...ple your receipt here Proof of the original purchase date is needed to obtain service under the warranty Consumer Support Troubleshooting Tips Operating Instructions Safety Instructions Care and Clean...

Page 24: ...a Individuals qualified to service their own appliances can have parts or accessories sent directly to their homes VISA MasterCard and Discover cards are accepted Order on line today 24 hours every da...

Reviews: