53
WavePro
™
Breaker Catalog Number Guide
W
E
2
D
A
Q
D
1
2
3
4
5
6
7
Trip unit codes (See Table A)
TU function
Code
none
X
LS
Á
A
LSG
Â
B
LSGZ1
Â
C
LSGZ2
Â
D
LSGD
¬ Â
E
LSGDZ1
¬ Â
F
LSGDZ2
¬ Â
G
LI
Á
J
LIG
Â
K
LIGZ1
Â
L
LIGD
¬ Â
M
TU function
Code
LIGDZ1
¬ Â
N
LSI
Á
P
LSIG
Â
Q
LSIGX
¬ Â
R
LSIGZ1
Â
S
LSIGZ2
Â
T
LSIGD
¬ Â
V
LSIGDZ1
¬ Â
W
LSIGDZ2
¬ Â
Y
¬
Not UL Listed
Á
Power+ available with LI, LS or LSI only
Â
GF is 3w/4w (See Note 1 below)
Rating
Sensor Plug
Code
none
X
60
¬
1
80
2
150
100
3
125
4
150
5
150
¬
5
200
6
400
225
7
250
8
300
9
400
A
300
¬
9
800
400
A
450
¬
B
500
C
Rating
Sensor Plug
Code
600
D
800
700
E
800
G
600
¬
D
800
G
1600 1000
H
1100
¬
J
1200
K
1600
M
750
¬
F
800
¬
G
1000
H
2000 1200
K
1500
¬
L
1600
M
2000
N
Rating
Sensor Plug
Code
1200
K
3200 1600
M
2400
P
3200
S
1600
M
2000
N
4000 2500
Q
3000
R
3600
¬
T
4000
V
3200
¬
S
5000 4000
¬
V
5000
¬
W
¬
Rating plug value not
available on Power+
trip unit
Usage
Code
AKD10/PBII/AV3 Access Equipment WE
Special “dead front shield” for use in W1
AKD-10/PBII/AV3 Access Equipment
Interrupting Capability/
Silver
Fuse Type
Code
“L” Fuse
Standard
(ex. WPS)
1
High
(ex. WPH)
2
Extended
(ex. WPX)
3
OFLO only
4
300A
Class “J” fuse
A
350A
Class “J” fuse
B
400A
Class “J” fuse
C
450A
Class “J” fuse
D
500A
Class “J” fuse
E
600A
Class “J” fuse
F
800A
Class “L” fuse
G
5
1000A
Class “L” fuse
H
6
1200A
Class “L” fuse
J
7
1600A
Class “L” fuse
K
8
2000A
Class “L” fuse
L
9
2500A
Silver “L” fuse
M
800A
“Welder” limiter
N
1200A “Welder”
limiter
P
1600A “Welder”
limiter
Q
2000A “Welder”
limiter
R
Frame
&
Sensor
Code (See Note 1)
800
none
A
150
B
400
C
800
D
1600
none
E
800
F
1600
G
2000
none
H
2000
J
3200
none
K
3200
L
4000
none
M
4000
N
5000
none
P
5000
R
Trip Unit type
Code
none (non-automatic)
X
MVT Plus
A
MVT M (metering & communications) B
MVT PM (relaying, metering
& communications)
C
MVT Plus (w/special GF curve)
D
MVT M (w/special GF curve)
E
MVT PM (w/special GF curve)
F
Power +
¬
G
Power + (w/GF)
¬ Â
H
Power + (w/Defeatable GF)
¬ Á Â
J
Power + (w/targets)
¬
K
Power + (w/targets & GF)
¬ Â
L
Power + (w/targets &
Defeatable GF)
¬ Á Â
M
¬
Power + is not available for 5000A frame breakers
Á
Not UL Listed
Â
GF is 3w/4w (See Note 1 below)
Table A
L = Long Time (LT)
S = Short Time (ST)
I
= Instantaneous (Inst)
G = Ground Fault (GF)
GD= Defeatable GF
X = Switchable ST or Inst and GF
Z1 = Zone Selective Interlocking—GF
Z2 = Zone Selective Interlocking—
GF and ST
Note 1: If 4 wire GF is required then the "A-Disc" [character position 14] must
be selected and the 4th wire (neutral) sensor must be ordered separately.
Refer to DEP-080 Product Catalog.
Sensor = "none" for non-automatic breakers
Equipment Usage
Frame Sizes & Interrupting Rating
Trip Unit Type, Characteristics & Trip Rating
S
T
Fuse Link
U
on
V
Phase B
W
Y