51
-
+
W1
W2
SHOT
ONE
S
OS
2
1
V
RES
NOTE
10
Y
Y
TC-1
M
1
R
2
(-)
(Y)
FUSE
A6
A5
FUSE
A7
1
MA
2
FUSE
4
2
G
1
3
G
A17
(+)
(X)
FUSE
TRIP
AUX
6
6C
L
AUX
5
5C
L
D
CC
2
A8
A18
1
CLOSE
A9
(Z)
(MOMENTARY)
(MOMENTARY)
TC-1
(-)
(Y)
FUSE
A6
A5
FUSE
1
MA
2
FUSE
(+)
(X)
FUSE
TRIP
AUX
6
6C
L
AUX
5
5C
L
A18
CLOSE
A9
(Z)
(MOMENTARY)
10
NOTE
RES
2
V
1
(MOMENTARY)
D
CC
2
1
OS
S
ONE
SHOT
W2
W1
+
-
A7
WAVEPRO CIRCUIT BREAKER
MANUALLY OPERATED
(SHOWN WITH OPTIONAL REMOTE CLOSE
DEVICE AND SHUNT TRIP DEVICE)
WAVEPRO™ CIRCUIT BREAKER
ELECTRICALLY OPERATED
-
+
W1
W2
SHOT
ONE
S
OS
2
1
V
RES
NOTE
10
Y
Y
TC-1
M
1
R
2
(-)
(Y)
FUSE
A6
A5
FUSE
A7
1
MA
2
FUSE
4
2
G
1
3
G
A17
(+)
(X)
FUSE
TRIP
AUX
6
6C
L
AUX
5
5C
L
D
CC
2
A8
A18
1
CLOSE
A9
(Z)
(MOMENTARY)
(MOMENTARY)
TC-1
(-)
(Y)
FUSE
A6
A5
FUSE
1
MA
2
FUSE
(+)
(X)
FUSE
TRIP
AUX
6
6C
L
AUX
5
5C
L
A18
CLOSE
A9
(Z)
(MOMENTARY)
10
NOTE
RES
2
V
1
(MOMENTARY)
D
CC
2
1
OS
S
ONE
SHOT
W2
W1
+
-
A7
WAVEPRO CIRCUIT BREAKER
MANUALLY OPERATED
(SHOWN WITH OPTIONAL REMOTE CLOSE
DEVICE AND SHUNT TRIP DEVICE)
WAVEPRO™ CIRCUIT BREAKER
ELECTRICALLY OPERATED
WAVEPRO CIRCUIT BREAKER
ELEC. & MAN. OPERATED
(OPTIONAL SECOND SHUNT TRIP DEVICE)
(MOMENTARY)
TC-2
(-)
(Y)
MB
FUSE
(+)
(X)
FUSE
2
C14
1
TRIP
AUX
13
13C
L
C5
(Z)
3
3C
A12
A3
L
AUX
1
1C
A10
A1
L
AUX
5
5C
6
6C
A5
A6
L
AUX
A7
4
4C
A13
A4
L
AUX
2
2C
A11
A2
L
AUX
4-STAGE AUXILIARY SWITCH CONTACTS
- CONTACT NOT AVAILABLE WITH FIRST SHUNT TRIP DEVICE OPTION.
3
3C
A12
A3
L
AUX
1
1C
A10
A1
L
AUX
11
11C
C12
C3
L
AUX
9
9C
C10
C1
L
AUX
13
13C
C14
C5
L
AUX
5
5C
6
6C
A5
A6
L
AUX
A7
14
14C
C15
C6
L
AUX
12
12C
C13
C4
L
AUX
10
10C
C11
C2
L
AUX
4
4C
A13
A4
L
AUX
2
2C
A11
A2
L
AUX
- CONTACT NOT AVAILABLE WITH FIRST SHUNT TRIP DEVICE OPTION.
- CONTACT NOT AVAILABLE WITH SECOND SHUNT TRIP DEVICE OPTION.
7-STAGE AUXILIARY SWITCH CONTACTS
Breaker Wiring Diagram
Notes:
(1) BREAKER SHOWN IN THE OPEN POSITION WITH THE
CLOSING SPRINGS DISCHARGED, BELL ALARM RESET.
(2) THIS DRAWING SHOWS ELECTRICAL CONNECTIONS
ONLY. THE EXACT LOCATION OF COMPONENTS CANNOT
BE DETERMINED FROM THIS DRAWING.
(3) THIS DRAWING DEPICTS STANDARD WIRING DIAGRAM
ONLY.
(4) DEFINITIONS: E/O-ELECTRICALLY OPERATED CIRCUIT
BREAKER; M/O-MANUALLY OPERATED CIRCUIT BREAKER.
(5) M/O BKRS WITH REMOTE CLOSE OPTION (WITH ONE
SHUNT TRIP DEVICE) AND ALL E/O (WITH ONE SHUNT
TRIP DEVICE ONLY) REQUIRE A 4-STAGE (MINIMUM)
AUXILIARY SWITCH.
(6) TWO SHUNT TRIP DEVICES REQUIRE A 7-STAGE
AUXILIARY SWITCH.
(7) A SECOND SHUNT DEVICE IS NOT AVAILABLE FOR WPS-50
TYPE BREAKERS.
(8) THE FOLLOWING DEVICES ARE NOT APPLICABLE ON
BKRS SUPPLIED WITH A POWER+™ TRIP UNIT; T/(COMM),
T/(ZSI), T/(VC), AND T/(CP).
(9) THE FOLLOWING DEVICES ARE NOT APPLICABLE ON
BKRS SUPPLIED WITH A MICROVERSATRIP PLUS™ TRIP
UNIT: T/(COMM), AND T/(VC).
(10) RESISTOR PROVIDED FOR AC CLOSE ONLY
1KOHM/25WATT FOR 120VAC, 4KOHM/25WATT FOR
240VAC.