background image

49-7762

7

Installation Instructions

INST

ALLA

TION INSTRUCTIONS

BEFORE YOU BEGIN

Read these instructions completely and 
carefully.

 

IMPORTANT –

 

Save these 

instructions for local inspector’s use.

 

IMPORTANT –

 

Observe all 

governing codes and ordinances.

•  

Note to Installer 

– Be sure to leave these 

instructions with the Consumer.

•  

Note to Consumer 

– Keep these instructions for 

future reference.

•  

Skill level 

– Installation of this appliance requires 

basic mechanical skills.

• Completion time 

±$SSUR[LPDWHO\KRXU

•  

We recommend that two people install  

this product.

•  

Proper installation is the responsibility  

of the installer.

•  

Product failure due to improper installation is not 

covered under the Warranty.

‡ <RX0867XVHDOOVXSSOLHGSDUWVDQGXVHSURSHU

installation procedures as described in these 
instructions when installing this air conditioner.

Questions?  Call 800.GE.CARES (800.432.2737) or Visit our Website at: GEAppliances.com

The 3-prong grounding plug minimizes the 
possibility of electric shock hazard. If the wall 
outlet you plan to use is only a 2-prong outlet,  
it is your responsibility to have it replaced with 
a properly grounded 3-prong wall outlet.

These models require 230/208-volt AC, protected 
with a time-delay fuse or circuit breaker. These 
models should be installed on their own single 
branch circuit for best performance and to prevent 
overloading house or apartment wiring circuits, which 
could cause a possible fire hazard from overheating 
wires.

ELECTRICAL REQUIREMENTS

  Power cord includes a current interrupter device. A 
test and reset button is provided on the plug case. The 
device should be tested on a periodic basis by first 
pressing the 

TEST

 button and then the 

RESET

 button 

while plugged into the outlet. If the 

TEST

 button does 

not trip or if the 

RESET

 button will not stay engaged, 

discontinue use of the air conditioner and contact a 
qualified service technician.

ELECTRICAL REQUIREMENTS 
(CONT)

TOOLS YOU WILL NEED

Phillips head screwdriver

Ruler or tape measure

Pencil

/HYHO

Scissors or knife

Drill and 1/8” drill bit

CAUTION

Do not, under any circumstances, cut or remove 
the third (ground) prong from the power cord.

Do not change the plug on the power cord of this 
air conditioner.

Aluminum house wiring may present special 
problems—consult a qualified electrician.

Summary of Contents for AHH24DW

Page 1: ...3 USING THE AIR CONDITIONER Controls 4 Remote Control 5 Cool Mode 5 Energy Saver Mode 5 Air Direction 6 CARE AND CLEANING Grille and Case 6 Air Filter 6 Outdoor Coils 6 Install Batteries in Remote 6...

Page 2: ...o every GE Appliances product and we think you will too Among other things registration of your appliance ensures that we can deliver important product information and warranty details when you need t...

Page 3: ...for R22 refrigerant only To avoid risk of injury or property damage the air conditioner should ONLY be serviced by a qualified servicer WARNING USE OF EXTENSION CORDS RISK OF FIRE Could cause serious...

Page 4: ...ir conditioner is on it can be set to automatically turn off in 1 to 24 hours How to set Press the Delay 1 24hr pad on the unit or the remote control Each touch of the Increase Decrease pads on the un...

Page 5: ...ting or if turned from a fan setting to a Cool VHWWLQJ LW PD WDNH DSSUR LPDWHO PLQXWHV IRU the compressor to start and cooling to begin Cooling Descriptions For Normal Cooling Select the Cool mode and...

Page 6: ...ith warm soapy water Rinse and let the filter dry before replacing it Do not clean the filter in a dishwasher CAUTION DO NOT operate the air conditioner without a filter because dirt and lint will clo...

Page 7: ...ng outlet it is your responsibility to have it replaced with a properly grounded 3 prong wall outlet These models require 230 208 volt AC protected with a time delay fuse or circuit breaker These mode...

Page 8: ...racket 2 LQGRZ RFN Bracket Remote Control Top Mounting Rail may be installed already Foam Seal 3 8 Bracket Screws 6 1 Wood Screws 8 2 1 2 Flat Head Bolt and RFN 1XW A B C D Temp Delay Hrs PARTS INCLUD...

Page 9: ...panels if needed to fit in a narrow window See the window opening dimensions All supporting parts must be secured to firm wood masonry or metal The electrical outlet must be within reach of the power...

Page 10: ...n the window A Install top mounting rail if not already installed with four type A screws B Slide left hand curtain assembly into left end of top and bottom mounting rail Repeat for right hand curtain...

Page 11: ...H WR the window sill Drill pilot holes if necessary Bottom rail Top rail Window sash SILL About 5 1 Wood Screws 2 1 Wood Screws 6 INSTALL OUTER CASE IN WINDOW D Thread nut onto bolt then thread the bo...

Page 12: ...ttach the window lock bracket to the upper window with a type C screw to secure the window in place A B A Top of lower window sash B Foam seal 9LQ O Wood 8 RETURN CHASSIS TO THE OUTER CASE A Once the...

Page 13: ...ake sure there are not curtains blinds or furniture blocking the front of the air conditioner The temp control may not be set properly Turn the temperature control to a higher number The air filter is...

Page 14: ...HVVRU F FOHV RQ DQG RII DWHU ZLOO FROOHFW LQ WKH EDVH SDQ GXULQJ KLJK KXPLGLW RU RQ UDLQ GD V 7KH ZDWHU PD RYHUIORZ DQG GULS IURP WKH outdoor side of the unit 7KH IDQ PD UXQ HYHQ ZKHQ WKH FRPSUHVVRU G...

Page 15: ...ailable you may be responsible for a trip charge or you may be required to bring the product WR DQ XWKRUL HG SSOLDQFHV 6HUYLFH ORFDWLRQ IRU VHUYLFH Q ODVND WKH ZDUUDQW H FOXGHV WKH FRVW RI shipping or...

Page 16: ...RXU warranty is still in effect You can purchase it on line anytime GE Appliances Services will still be there after your ZDUUDQW H SLUHV Q WKH 86 GEAppliances com ge service and support shop for exte...

Page 17: ...isitos de la Ventana 9 Preparaci n del Acondicionador de Aire 10 Instalaci n del Acondicionador de Aire 11 CONSEJOS PARA LA SOLUCI N DE PROBLEMAS 12 Sonidos de Funcionamiento Normal 13 SOPORTE AL CLIE...

Page 18: ...eemos que usted tambi n Entre otras cosas el registro de su electrodom stico asegura que podamos entregarle informaci n importante del producto y detalles de la garant a cuando los necesite Registre s...

Page 19: ...U XQ WpFQLFR FDOLILFDGR ADVERTENCIA LEA Y GUARDE ESTAS INSTRUCCIONES ADVERTENCIA USO DE PROLONGADORES RIESGO DE INCENDIO Podr a ocasionar lesiones graves o la muerte 12 XVH XQ SURORQJDGRU FRQ HVWH FRQ...

Page 20: ...DUD FRQILJXUDU OD YHORFLGDG GHO YHQWLODGRU en High Alto Med Medio o Low Bajo en la unidad 6 Tecla de Retraso Delay ON Retraso Encendido Cuando el acondicionador de aire se encuentre apagado se podr co...

Page 21: ...y que comience la refrigeraci n Descripciones de enfriamiento Para enfriamiento normal Seleccione el modo Cool Fr o y ventilador High Alto o Med Medio con una temperatura de ajuste media Para enfriami...

Page 22: ...con agua caliente y jab n Enjuague y deje VHFDU HO ILOWUR DQWHV GH VX UHHPSOD R 1R OLPSLH HO ILOWUR HQ XQ lavavajillas PRECAUCI N 12 XWLOLFH HO DFRQGLFLRQDGRU GH DLUH sin un filtro ya que la suciedad...

Page 23: ...red de 3 cables correctamente conectado a tierra OJXQRV PRGHORV UHTXLHUHQ YROWLRV GH corriente alterna protegidos por un fusible de dilataci n de tiempo o un cortacircuitos Estos modelos deber an inst...

Page 24: ...Ventana Control Remoto Riel de Montaje Superior HV SRVLEOH TXH D HVWp LQVWDODGR Sellador de Gomaespuma Tornillos de Soporte de Tornillos de Madera de Tornillo de Cabeza Plana de RQWUDWXHUFD A C D PART...

Page 25: ...las partes de apoyo deben quedar totalmente aseguradas a alg n metal mamposter a o a la madera El tomacorriente el ctrico debe estar al alcance del cable el ctrico del acondicionador de aire Siga las...

Page 26: ...zquierdo en el extremo izquierdo del riel de montaje superior e inferior Repita este proceso en la junta de la cortina del lado derecho C Ajuste las tiras de retenci n de la cortina a los costados de...

Page 27: ...p rail Window sash SILL About 5 7RUQLOORV GH 0DGHUD GH Tornillos de 0DGHUD GH 6 INSTALE LA CAJA EXTERNA EN LA VENTANA D Enrosque la tuerca en el tornillo luego enrosque el tornillo en el soporte trian...

Page 28: ...QD YH TXH OD FDMD HVWp DGKHULGD GH IRUPD VHJXUD D la ventana vuelva a instalar el acondicionador de aire Dos personas deben levantar el acondicionador de aire y deslizar el mismo sobre la caja Vuelva...

Page 29: ...lujo de aire est restringido Cerci rese de que no existe ninguna cortina persiana o mueble bloqueando el frente del acondicionador de aire El control de temperatura no est ajustado apropiadamente En l...

Page 30: ...LFOR HQWUH HQFHQGLGR DSDJDGR O DJXD VH DFXPXOD HQ OD EDQGHMD GXUDQWH GtDV OOXYLRVRV R FRQ PXFKD KXPHGDG O DJXD SRGUtD GHUUDPDUVH JRWHDU GHVGH HO lado externo de la unidad O YHQWLODGRU SRGUtD IXQFLRQDU...

Page 31: ...hacerse cargo de los costes de env o o bien podr a solicit rsele que lleve el producto a una centro de servicio de GE Appliances autorizado para realizar la reparaci n En Alaska la garant a excluye e...

Page 32: ...a a n est vigente La puede adquirir en cualquier momento a trav s de Internet Los servicios de GE Appliances a n estar n all cuando su garant a caduque Q 88 GEAppliances com ge service and support sho...

Reviews: