background image

13

Through-the-Wall Installation Instructions—Optional

The case may be installed through-the-wall
in both existing and new construction.

Read completely, then follow step-by-step.

NOTE: Obtain all materials locally for
mounting the air conditioner through-
the-wall.

IMPORTANT

Through-the-wall installation is not
appropriate if any of the side or top louvers
in the case will be obstructed by the wall.

All side and top louvers in the case must
project on the outdoor side of the wall.

The room side of the case must project 
into the room far enough to maximize the
balance of the unit.

The case must be installed level from side-
to-side and with a slight tilt from front to
rear. Use a level; no more than a 1/2 bubble
will be the correct case slant to the outside.

Lintel angle is required to support bricks or
blocks above opening.

Flashing is required and should extend the
length of the opening to ensure no inside
cavity leakage occurs.

Remove the air conditioner from the case.
For specific instruction, refer to the Window
Installation Instructions.

Make certain that a wall receptacle is
available close to the hole location or make
arrangements to install a receptacle.

Place the case in the wall opening and 
place wood support strips between the case
bottom and the flashing on both sides of the
bottom rail. They should be the same height
as the bottom rail and the same length as
the wall opening.

1

A

B

FINISH THE WALL OPENING

Caulk all four sides on the outdoor side of
the case to prevent moisture from getting
through to the interior wall. Use of flashing
(drip rail) will further prevent water from
dripping inside the wall and down the
outside of the building.

Place the air conditioner into the case. 
For specific instruction, refer to the Window
Installation Instructions.

2

IMPORTANT 

(cont.)

Secure with 14 wood screws anchored at
least an inch into the wall support structure.

NOTE:

Drill pilot holes, if necessary, for

proper installation. If the frame is oversized,
use shims to prevent case distortion.

1

D

A

B

Lintel angle

Plaster line

Trim molding
(if desired)

INSIDE

Bottom rail

Wood filler and
caulking (above
and below the
flashing)

Air louvers
(top and
sides must
project on the
outdoor side
of the wall)

OUTSIDE

Flashing 
(Drip rail)

Case 
bottom

Bottom
rail

Flashing 
(Drip rail)

Wood support strips

Caulking

C

Summary of Contents for AGW12AK

Page 1: ...stallation Optional 13 Window Installation 8 12 Troubleshooting Tips 14 Normal Operating Sounds 15 Consumer Support Consumer Support 18 Warranty 17 3828A21031L 49 7565 11 06 JR Owner s Manual and Inst...

Page 2: ...product with refrigerants check with the company handling disposal about what to do SAFETY PRECAUTIONS Do not under any circumstances cut or remove the third ground prong from the power cord For perso...

Page 3: ...nst the use of an extension cord However if you must use an extension cord it is absolutely necessary that it be a UL listed 14 gauge 3 wire grounding type appliance extension cord having a grounding...

Page 4: ...When the air conditioner is off it can be set to automatically come on in 1 to 12 hours at its previous setting Each touch will set the timer in hours OFF When the air conditioner is on it can be set...

Page 5: ...iptions For Normal Cooling Select the Cool mode and HIGH F3 or MED F2 fan with a middle set temperature For Maximum Cooling Select the Cool mode and HIGH F3 fan with a lower set temperature For Quiete...

Page 6: ...d regularly If they are clogged with dirt or soot they may be professionally cleaned Outdoor Coils The air filter behind the front grille should be checked and cleaned at least every 30 days or more o...

Page 7: ...a 115 120 volt a c 60 Hz grounded outlet protected with a 15 amp time delay fuse or circuit breaker The 3 prong grounding plug minimizes the possibility of electric shock hazard If the wall outlet you...

Page 8: ...t Right accordion panel Foam top window gasket Window sash seal Left accordion panel Type B 3 Type C 5 Bolt 2 Nut 2 Frame guide 2 Top mounting rail seal strip Top mounting rail PARTS INCLUDED Appearan...

Page 9: ...TORM WINDOW REQUIREMENTS A storm window frame will not allow the air conditioner to tilt toward the outside and will keep it from draining properly To adjust for this attach a piece of wood to the sto...

Page 10: ...ing and attach the seal to the underside of the window sash A 4 PREPARE THE WINDOW AND THE CASE CONT Carefully insert the plastic frame guides into the bottom of the case on each side Remove the backi...

Page 11: ...n the sill Attach the sill supports to the case track hole in relation to the selected position using 2 type A screws in each support E D C B A 5 Window Installation Instructions Bolt Nut Sill support...

Page 12: ...e Caulk or weather strip any gaps or openings to the outside to seal the installation D C B Window Installation Instructions INSTALL THE WINDOW LOCKING BRACKET AND THE FOAM TOP WINDOW GASKET Attach a...

Page 13: ...ertain that a wall receptacle is available close to the hole location or make arrangements to install a receptacle Place the case in the wall opening and place wood support strips between the case bot...

Page 14: ...When the air conditioner is first turned on you need to allow time for the room to cool down Cold air is escaping Check for open furnace floor registers and cold air returns Set the air conditioner s...

Page 15: ...fficiency You may hear the thermostat click when the compressor cycles on and off Water will collect in the base pan during high humidity or on rainy days The water may overflow and drip from the outd...

Page 16: ...16 Consumer Support Troubleshooting Tips Operating Instructions Safety Instructions Installation Instructions Notes...

Page 17: ...equential damage caused by possible defects with this air conditioner What Is Not Covered This warranty is extended to the original purchaser and any succeeding owner for products purchased for home u...

Page 18: ...bilities check out our Website today For the hearing impaired please call 800 TDD GEAC 800 833 4322 Parts and Accessories ge com Individuals qualified to service their own appliances can have parts or...

Page 19: ...ose para instalar el acondicionador de aire 7 Solucionar problemas 15 Sonidos normales de operaci n 16 Apoyo al consumidor Apoyo al consumidor 18 Garant a 17 3828A21031L 49 7565 11 06 JR Manual del pr...

Page 20: ...de alg n producto que contenga refrigerantes p ngase en contacto con la compa a que se encarga de recoger su basura para que le indiquen qu hacer PRECAUCIONES DE SEGURIDAD Bajo ninguna circunstancia c...

Page 21: ...co de extensi n es absolutamente necesario que el mismo est listado bajo UL sea calibre 14 del tipo de 3 tomas con conexi n a tierra para electrodom sticos y el ndice el ctrico debe ser de 15 amperios...

Page 22: ...el acondicionador de aire est encendido puede ajustarse para que se apague autom ticamente dentro de 1 a 12 horas Cada toque ajustar el tiempo en horas Para cancelar el sincronizador presione la tecla...

Page 23: ...ura de ajuste menor Para enfriamiento silencioso y enfriamiento nocturno Seleccione el modo de ventilador Cool y LOW F1 BAJO con una temperatura de ajuste media NOTA Si cambia de un ajuste Cool Fr o a...

Page 24: ...tro de aire detr s de la rejilla frontal debe inspeccionarse y limpiarse por lo menos cada 30 d as o m s a menudo si fuese necesario Para retirarlo Abra la rejilla de entrada hacia abajo tirando de la...

Page 25: ...leta y cuidadosamente IMPORTANTE Guarde estas instrucciones para uso del inspector local IMPORTANTE Observe todos los c digos y rdenes de ley Nota al instalador Aseg rese de dejar estas instrucciones...

Page 26: ...l de acorde n izquierdo Tipo B 3 Tipo C 5 Tornillo 2 Tuerca 2 Gu a del marco 2 Cinta de sellado del riel de montaje superior Top mounting rail PARTES INCLUIDAS apariencia puede variar Instrucciones de...

Page 27: ...TORMENTAS Un marco de ventana de tormentas no permitir que el acondicionador de aire se incline hacia el exterior y evitar que drene apropiadamente Para solucionar este problema adhiera un pedazo de...

Page 28: ...la banda de sellado del riel de montura superior y nala al fondo del riel de montaje superior Instale el riel de montaje superior con 3 tornillos tipo A en el interior de la caja Inserte los marcos pa...

Page 29: ...alejado en el umbral Una los soportes del umbral al agujero de trayectoria de la caja en relaci n con la posici n seleccionada usando dos tornillos tipo A en cada soporte E D C B A 5 Tornillo Tuerca S...

Page 30: ...n localizada al lado del panel de control de la unidad como se muestra Una la parrilla del frente a la caja insertando las orejillas en la parrilla en las ranuras en el frente de la caja Empuje la pa...

Page 31: ...buja Es necesaria una escuadra de lintel para dar soporte a los ladrillos o bloques que se encuentran por encima de la abertura Se necesitan tapajuntas que deben extenderse a lo largo de la abertura p...

Page 32: ...ci n Coloque el acondicionador de aire hacia el interior de la caja Para instrucciones espec ficas refi rase a las Instrucciones para la instalaci n en una ventana 2 ngulo del lintel L nea del yeso Mo...

Page 33: ...rese de que los registros de la calefacci n no est n abiertos y se encuentran retornando el aire fr o Coloque la ventanilla del acondicionador de aire en la posici n cerrada Las bobinas de enfriamien...

Page 34: ...ora la eficiencia Quiz s escuche que el termostato hace clic cuando el compresor hace ciclo entre encendido y apagado El agua se acumula en la bandeja durante d as lluviosos o con mucha humedad El agu...

Page 35: ...mayor Da os incidentales o consecuenciales causados por defectos posibles con este acondicionador de aire Lo que no est cubierto Esta garant a se extiende al comprador original y cualquier comprador...

Page 36: ...on dificultades auditivas favor de llamar al 800 TDD GEAC 800 833 4322 Piezas y accesorios ge com Aquellos individuos con la calificaci n necesaria para reparar sus propios electrodom sticos pueden pe...

Reviews: