Read completely, then follow step-by-step.

Window Requirements

These instructions are for a standard double-
hung window. You will need to modify them for
other types of windows.

The air conditioner can be installed without the
accordion panels if needed to fit in a narrow
window. See the window opening dimensions to
the right.

All supporting parts must be secured to firm
wood, masonry or metal.

The electrical outlet must be within reach of the
power cord.

Window opening dimensions are for a standard double-hung
window.

18

min.

29

to 41

(With accordion panels)

26

″ 

min.

(Without accordion panels)

Storm Window Requirements

A storm window frame will not allow the air

conditioner to tilt towards the outside and will keep

it from draining properly. To adjust for this, attach a

piece of wood to the stool.

WOOD PIECES—

WIDTH:

2

LENGTH: 

Long enough to fit inside the window

frame.

THICKNESS: 

To determine the thickness, place a

piece of wood on the stool to make it 1/2

higher

than the top of the storm window frame.
Attach securely with nails or screws provided by 

the installer.

1/2

higher

than frame

Storm window
frame

Wood

Stool

1

2

Summary of Contents for AG_14 - 14,000 BTU models

Page 1: ...GE Appliances Room Air Conditioners Pub No 49 7378 1 CG 11 98 AG_14 14 000 BTU models AG_18 18 000 BTU models Owner s Manual Installation Instructions...

Page 2: ...er 8 Window Installation 9 13 Troubleshooting Tips Before You Call For Service 14 Normal Operating Sounds 14 Customer Service Warranty 15 Service Telephone Numbers Back Cover FOR YOUR RECORDS Write th...

Page 3: ...in the vicinity of this or any other appliance SAFETY PRECAUTIONS 3 Customer Service Troubleshooting Tips Operating Instructions Safety Instructions Installation Instructions Do not under any circums...

Page 4: ...end against the use of an adapter plug However if you must use an adapter where local codes permit a temporary connection may be made to a properly grounded 2 prong wall outlet by use of a UL listed a...

Page 5: ...COOL or MED COOL with the temp control at midpoint For Maximum Cooling Select HIGH COOL with the temp control at the highest number available on your knob For Quieter Nighttime Cooling Select LOW COO...

Page 6: ...l louvers adjusts the air direction up or down Energy Saver on some models The energy saver switch controls the fan ON The fan and compressor cycle on and off together This results in wider variations...

Page 7: ...and pull it down Clean the filter with warm soapy water Rinse and let the filter dry before replacing it CAUTION DO NOT operate the air conditioner without a filter because dirt and lint will clog it...

Page 8: ...s and ordinances CAUTION Do not under any circumstances cut or remove the third ground prong from the power cord Do not change the plug on the power cord of this air conditioner Aluminum house wiring...

Page 9: ...indow Installation Instructions Parts Included Type A 14 Support bracket 2 Sill bracket 2 Type B 7 Type C 5 Type D 2 Carriage Bolt 2 Lock Nut 4 Window locking bracket Frame guide 2 Top mounting rail T...

Page 10: ...ee the window opening dimensions to the right All supporting parts must be secured to firm wood masonry or metal The electrical outlet must be within reach of the power cord Window opening dimensions...

Page 11: ...mounting rail Install the top mounting rail with 3 type A screws on the inside of the case Insert the frames for the accordion panels into the top mounting rail and the frame guides Attach the accordi...

Page 12: ...tach the brackets to the case using two type D screws and 2 lock nuts Adjust the carriage bolts and the lock nuts in each support so that the case is installed with a slight downward tilt about 1 4 to...

Page 13: ...ntgrilletothecasebyinsertingthe tabsonthegrilleintotheslotsonthefrontofthe case Pushthegrilleinuntilitsnapsintoplace Lift the inlet grille and secure the front frame with a type A screw Lower the inle...

Page 14: ...should blocking the front of the air conditioner The temp control may Turn the knob to a higher number The highest setting not be set high enough provides maximum cooling The air filter is dirty Clea...

Page 15: ...er or installer You are responsible for providing adequate electrical connecting facilities Failure of the product resulting from modifications to the product or due to unreasonable use including fail...

Page 16: ...anty expires Parts and Accessories 800 626 2002 Individuals qualified to service their own appliances can have parts or accessories sent directly to their homes VISA MasterCard and Discover cards are...

Reviews: