background image

Operating Instructions

Safety Instructions

Installation Instructions

Troubleshooting T

ips

Customer Service

Service Telephone Numbers.

GE Answer Center

®

800.626.2000

The GE Answer Center® is open 24 hours a day, 7 days a week. 

In-Home Repair Service 

800-GE-CARES (800-432-2737)

Expert GE repair service is only a phone call away. 

Special Needs Service 

800.626.2000

800-TDD-GEAC (800-833-4322)

GE offers, free of charge, a brochure to assist in planning a barrier-free kitchen for persons 

with limited mobility.

Service Contracts 

800-626-2224

Purchase a GE service contract while your warranty is still in effect and you’ll receive a 

substantial discount. GE Consumer Service will still be there after your warranty expires.

Parts and Accessories 

800-626-2002

Individuals qualified to service their own appliances can have parts or accessories sent directly 

to their homes (VISA, MasterCard and Discover cards are accepted). 

Instructions contained in this manual cover procedures to be performed by any user. Other servicing
generally should be referred to qualified service personnel. Caution must be exercised, since
improper servicing may cause unsafe operation. 

Service Satisfaction 

If you are not satisfied with the service you receive from GE: 

First, 

contact the people who serviced your appliance. 

Next, 

if you are still not pleased, write all the details—including your phone number—to:

Manager, Customer Relations

GE Appliances

Appliance Park

Louisville, KY 40225

Finally, 

if your problem is still not resolved, write: 

Major Appliance Consumer Action Program

20 North Wacker Drive

Chicago, IL 60606

Printed in Korea

16

Summary of Contents for AG_14 - 14,000 BTU models

Page 1: ...GE Appliances Room Air Conditioners Pub No 49 7378 1 CG 11 98 AG_14 14 000 BTU models AG_18 18 000 BTU models Owner s Manual Installation Instructions...

Page 2: ...er 8 Window Installation 9 13 Troubleshooting Tips Before You Call For Service 14 Normal Operating Sounds 14 Customer Service Warranty 15 Service Telephone Numbers Back Cover FOR YOUR RECORDS Write th...

Page 3: ...in the vicinity of this or any other appliance SAFETY PRECAUTIONS 3 Customer Service Troubleshooting Tips Operating Instructions Safety Instructions Installation Instructions Do not under any circums...

Page 4: ...end against the use of an adapter plug However if you must use an adapter where local codes permit a temporary connection may be made to a properly grounded 2 prong wall outlet by use of a UL listed a...

Page 5: ...COOL or MED COOL with the temp control at midpoint For Maximum Cooling Select HIGH COOL with the temp control at the highest number available on your knob For Quieter Nighttime Cooling Select LOW COO...

Page 6: ...l louvers adjusts the air direction up or down Energy Saver on some models The energy saver switch controls the fan ON The fan and compressor cycle on and off together This results in wider variations...

Page 7: ...and pull it down Clean the filter with warm soapy water Rinse and let the filter dry before replacing it CAUTION DO NOT operate the air conditioner without a filter because dirt and lint will clog it...

Page 8: ...s and ordinances CAUTION Do not under any circumstances cut or remove the third ground prong from the power cord Do not change the plug on the power cord of this air conditioner Aluminum house wiring...

Page 9: ...indow Installation Instructions Parts Included Type A 14 Support bracket 2 Sill bracket 2 Type B 7 Type C 5 Type D 2 Carriage Bolt 2 Lock Nut 4 Window locking bracket Frame guide 2 Top mounting rail T...

Page 10: ...ee the window opening dimensions to the right All supporting parts must be secured to firm wood masonry or metal The electrical outlet must be within reach of the power cord Window opening dimensions...

Page 11: ...mounting rail Install the top mounting rail with 3 type A screws on the inside of the case Insert the frames for the accordion panels into the top mounting rail and the frame guides Attach the accordi...

Page 12: ...tach the brackets to the case using two type D screws and 2 lock nuts Adjust the carriage bolts and the lock nuts in each support so that the case is installed with a slight downward tilt about 1 4 to...

Page 13: ...ntgrilletothecasebyinsertingthe tabsonthegrilleintotheslotsonthefrontofthe case Pushthegrilleinuntilitsnapsintoplace Lift the inlet grille and secure the front frame with a type A screw Lower the inle...

Page 14: ...should blocking the front of the air conditioner The temp control may Turn the knob to a higher number The highest setting not be set high enough provides maximum cooling The air filter is dirty Clea...

Page 15: ...er or installer You are responsible for providing adequate electrical connecting facilities Failure of the product resulting from modifications to the product or due to unreasonable use including fail...

Page 16: ...anty expires Parts and Accessories 800 626 2002 Individuals qualified to service their own appliances can have parts or accessories sent directly to their homes VISA MasterCard and Discover cards are...

Reviews: