Preparing to install the air conditioner.

Read these instructions completely and carefully.

NOTE TO INSTALLER:

Leave these instructions with

the air conditioner after installation is completed.

NOTE TO CONSUMER: 

Keep this Owner’s Manual

and Installation Instructions for future use.

IMPORTANT NOTES:

For personal safety, this air conditioner must be
properly grounded.

It is important to have the wall outlet and circuit
checked by a qualified electrician if there is any
doubt as to whether a proper ground exists.

Follow National Electric Codes (NEC) and/or local
codes and ordinances.

CAUTION:

Do not, under any circumstances, cut or
remove the third (ground) prong from the
power cord.

Do not change the plug on the power cord
of this air conditioner.

Aluminum house wiring may present
special problems—consult a qualified
electrician.

Before You Begin

Some models require 115/120-volt a.c.,
60 Hz grounded outlet protected with
a 15-amp time delay fuse or circuit breaker.

The 3-prong grounding plug minimizes the
possibility of electric shock hazard. If the wall outlet
you plan to use is only a 2-prong outlet, it is your
responsibility to have it replaced with a properly
grounded 3-prong wall outlet.

Some models require 230/208-volt a.c.,
protected with a time delay fuse or circuit
breaker. These models should be installed
on their own single branch circuit for best
performance and to prevent overloading
house or apartment wiring circuits, which
could cause a possible fire hazard from
overheating wires.

Electrical Requirements

■ 

Phillips-head screwdriver

■ 

Flat-blade screwdriver

■ 

Ruler or tape measure

■ 

Scissors or knife

■ 

Pencil

■ 

Level

■ 

Hammer

Tools You Will Need

Summary of Contents for AG_14 - 14,000 BTU models

Page 1: ...GE Appliances Room Air Conditioners Pub No 49 7378 1 CG 11 98 AG_14 14 000 BTU models AG_18 18 000 BTU models Owner s Manual Installation Instructions...

Page 2: ...er 8 Window Installation 9 13 Troubleshooting Tips Before You Call For Service 14 Normal Operating Sounds 14 Customer Service Warranty 15 Service Telephone Numbers Back Cover FOR YOUR RECORDS Write th...

Page 3: ...in the vicinity of this or any other appliance SAFETY PRECAUTIONS 3 Customer Service Troubleshooting Tips Operating Instructions Safety Instructions Installation Instructions Do not under any circums...

Page 4: ...end against the use of an adapter plug However if you must use an adapter where local codes permit a temporary connection may be made to a properly grounded 2 prong wall outlet by use of a UL listed a...

Page 5: ...COOL or MED COOL with the temp control at midpoint For Maximum Cooling Select HIGH COOL with the temp control at the highest number available on your knob For Quieter Nighttime Cooling Select LOW COO...

Page 6: ...l louvers adjusts the air direction up or down Energy Saver on some models The energy saver switch controls the fan ON The fan and compressor cycle on and off together This results in wider variations...

Page 7: ...and pull it down Clean the filter with warm soapy water Rinse and let the filter dry before replacing it CAUTION DO NOT operate the air conditioner without a filter because dirt and lint will clog it...

Page 8: ...s and ordinances CAUTION Do not under any circumstances cut or remove the third ground prong from the power cord Do not change the plug on the power cord of this air conditioner Aluminum house wiring...

Page 9: ...indow Installation Instructions Parts Included Type A 14 Support bracket 2 Sill bracket 2 Type B 7 Type C 5 Type D 2 Carriage Bolt 2 Lock Nut 4 Window locking bracket Frame guide 2 Top mounting rail T...

Page 10: ...ee the window opening dimensions to the right All supporting parts must be secured to firm wood masonry or metal The electrical outlet must be within reach of the power cord Window opening dimensions...

Page 11: ...mounting rail Install the top mounting rail with 3 type A screws on the inside of the case Insert the frames for the accordion panels into the top mounting rail and the frame guides Attach the accordi...

Page 12: ...tach the brackets to the case using two type D screws and 2 lock nuts Adjust the carriage bolts and the lock nuts in each support so that the case is installed with a slight downward tilt about 1 4 to...

Page 13: ...ntgrilletothecasebyinsertingthe tabsonthegrilleintotheslotsonthefrontofthe case Pushthegrilleinuntilitsnapsintoplace Lift the inlet grille and secure the front frame with a type A screw Lower the inle...

Page 14: ...should blocking the front of the air conditioner The temp control may Turn the knob to a higher number The highest setting not be set high enough provides maximum cooling The air filter is dirty Clea...

Page 15: ...er or installer You are responsible for providing adequate electrical connecting facilities Failure of the product resulting from modifications to the product or due to unreasonable use including fail...

Page 16: ...anty expires Parts and Accessories 800 626 2002 Individuals qualified to service their own appliances can have parts or accessories sent directly to their homes VISA MasterCard and Discover cards are...