background image

4

About the controls on the air conditioner.

Controls

Fan

Fan

Remote Control

  Delay  timer  Increase 

  Auto  Fan  on

Fan speed Increase

 Unit power on/off

NOTE: The display always 

shows the room temperature 

except when setting the Set 

temperature or the Delay timer.

Air Conditioner Controls

Light indicates the 
delay timer is set.

Light indicates the unit 
is in the temperature or 
delay time Set mode.

Delay 1–24hr

Delay timer  
Decrease

  Mode  select

Fan speed  
Decrease

Temperature  
set Increase  
and Decrease

Features and appearance will vary. 
Lights next to the touch pads on the air conditioner control panel indicate the selected settings

.

 

Power Pad

Turns air conditioner on and off. When turned 

on, the display will show the room temperature.

 

Display

Shows the room temperature or time remaining 

on the Delay timer. Shows the Set temperature 

while setting the temperature in Cool or Energy 

Saver modes. The Set light will turn on while 

setting.

 

Temp Increase 

Ÿ

 

/Decrease 

ź

 

Pads

Use to set temperature when in Cool or Energy 

Saver mode. The Set light will turn on while 

setting.

 

Delay Timer Increase

Ÿ

 (+) /Decrease 

ź

(–) 

Pads

Each touch of the Increase 

Ÿ

 / Decrease 

ź

 

pads on the unit or the Increase 

+ 

Decrease 

 pads on the remote control will set the delay 

time when using the Delay 1–24hr

 

timer. The 

Set light will turn on while setting.

 

Fan Speed Pads

Use to set the fan speed to Low, Med, High  

or Auto on the unit. NOTE: On the remote 

control, use the fan speed Increase 

Decrease 

 pads to set the fan speeds to Low, 

Med or High. Use the Auto pad to turn Auto  

fan on.

 

Mode Pad

Use to set the air conditioner to Cool, Energy 

Saver or Fan Only mode.

 

Delay Pads/Delay 1-24hr Pad

'HOD\21³When the air conditioner is off, it can 

be set to automatically come on in 1 to 24 hours 

at its previous mode and fan settings. 
'HOD\2))³When the air conditioner is on,  

it can be set to automatically turn off in 1 to  

24 hours. 
How to set:
Press the Delay 1–24hr pad on the unit or the 

Delay pad on the remote control.  Each touch 

of the Increase 

Ÿ

 

Decrease

ź

pads on the 

unit or the Increase 

Decrease 

 

pads on 

the remote control will set the timer in 1-hour 

intervals. The Set light will turn on while setting.
To review the remaining time on the Delay 

1–24hr timer, press the Delay 1–24hr pad on 

the unit or the Delay pad on the remote control. 

Use the Increase 

Ÿ

 / Decrease 

ź

 pads on the 

unit or the Increase 

+ 

Decrease 

 

pads on the 

remote control to set a new time if desired.
To cancel the timer, press the Delay 1–24hr pad 

until the light on the Delay 1–24hr pad goes off.

Note: The default temperature reading on the display is degree Fahrenheit ( °F).  To change the display to 
degree Celcius (°C), press the Temp Increase 

Ÿ

 and Temp Decrease 

ź

 buttons together and hold for 3 

seconds.  Repeat the process to change back to degree Fahrenheit (°F)

Summary of Contents for AEZ12 Series

Page 1: ...Cover Warranty 14 49 7657 2 10 13 GE AEW10 AEZ10 AEW12 AEZ12 Owner s Manual and Installation Instructions Write the model and serial numbers here Model _________________________ Serial ______________...

Page 2: ...ctrician These R410A air conditioning systems require contractors and technicians to use tools equipment and safety standards approved for use with this refrigerant DO NOT use equipment certified for...

Page 3: ...INSTRUCTIONS RISK OF FIRE Could cause serious injury or death DO NOT use an extension cord with this Window Air Conditioner DO NOT use surge protectors or multi outlet adaptors with this Window Air Co...

Page 4: ...ill turn on while setting Fan Speed Pads Use to set the fan speed to Low Med High or Auto on the unit NOTE On the remote control use the fan speed Increase Decrease pads to set the fan speeds to Low M...

Page 5: ...ddle set temperature Energy Saver Mode Controls the fan ON 7KH IDQ ZLOO F FOH RQ DQG RII ZLWK WKH compressor This results in wider variations of room temperature and humidity Normally used when the ro...

Page 6: ...iding it back into position NOTES Use 2 AAA 1 5 volt alkaline batteries Do not use rechargeable batteries Remove the batteries from the remote control if the system is not going to be used for a long...

Page 7: ...plug minimizes the possibility of electric shock hazard If the wall outlet you plan to use is only a 2 prong outlet it is your responsibility to have it replaced with a properly grounded 3 prong wall...

Page 8: ...ation Instructions Right accordion panel Foam top window gasket Left accordion panel Screw 6 Window sash seal Air conditioner Window locking bracket 1 PARTS INCLUDED Appearance may vary Frame locking...

Page 9: ...els if needed to fit in a narrow window See the window opening dimensions t All supporting parts must be secured to firm wood masonry or metal t The electrical outlet must be within reach of the power...

Page 10: ...ly constructed windows attach the window locking bracket to the window side jamb with one screw B C Wood Vinyl 3 Screws C 10 INSTALL THE AIR CONDITIONER IN THE WINDOW Place the air conditioner on the...

Page 11: ...NH VXUH WKHUH DUH QR FXUWDLQV EOLQGV RU IXUQLWXUH not cool as it should blocking the front of the air conditioner The temp control may 2Q PRGHOV ZLWK WRXFK SDGV Q WKH Cool mode press the not be set co...

Page 12: ...12 Notes...

Page 13: ...Notes GEAppliances com...

Page 14: ...KY 40225 Properly pack your unit We recommend using the original carton and packing materials Return the product to the retail location where it was purchased Include in the package a copy of the sale...

Page 15: ...strucciones de instalaci n 21 24 Solucionar problemas 25 Sonidos de operaci n normales 25 Servicio al consumidor Garant a 26 Servicio al consumidor 27 15 Escriba los n meros de modelo y serie aqu de M...

Page 16: ...azar el recept culo Estos sistemas de acondicionadores de aire R410A requieren que los contratistas y t cnicos usen herramientas equipos y est ndares de seguridad aprobados para su uso con este refrig...

Page 17: ...onar lesiones graves o la muerte NO use un prolongador con este Acondicionador de Aire de Ventana NO use protectores contra picos de tensi n ni adaptadores para m ltiples tomacorrientes con este Acond...

Page 18: ...de aire est encendido puede ajustarse para que se apague autom ticamente dentro de 1 a 24 horas C mo realizar el ajuste Pulse la tecla Delay 1 24hr Retardo 1 24h en la unidad o Delay pad Retardo del c...

Page 19: ...nly Solo ventilador Energy Saver Mode Modo de ahorro de energ a Controla el ventilador ON ENCENDIDO O YHQWLODGRU KDUi XQ FLFOR de encendido y apagado con el compresor Este resulta en variaciones mayor...

Page 20: ...tes de colocarlo otra vez en su lugar No lave el filtro en un lavavajillas PRECAUCI N NO OPERE el acondicionador de aire sin el filtro debido a que la suciedad y las pelusas lo obstruir n y reducir n...

Page 21: ...te acondicionador de aire Los cables caseros de aluminio podr an presentar problemas especiales Consulte a un t cnico electricista calificado ANTES DE INICIAR Lea estas instrucciones completa y cuidad...

Page 22: ...ivel Tijeras o cuchilla Un destornillador con hoja plana Panel de acorde n derecho Empaque superior de espuma de la ventana Panel de acorde n izquierdo Tornillo 6 Sello del marco de la ventana Acondic...

Page 23: ...del marco de la ventana GRUESO Para determinar el grueso coloque un pedazo de madera en el umbral para hacerla 1 2 m s alta que la parte superior del marco de la ventana de tormentas o del marco vinil...

Page 24: ...el soporte para bloqueo de ventana a el marco de la ventana con uno tornillo para prevenir da o a la ventana y vidro quebrado B C Madera Vinilo INSTALE EL ACONDICIONADOR DE AIRE EN LA VENTANA Coloque...

Page 25: ...ando tCerci rese de que los registros de la calefacci n no est n abiertos y se encuentran retornando el aire fr o Las bobinas de enfriamiento tVer Acondicionador de aire congel ndose m s adelante se c...

Page 26: ...tenimiento razonable y necesario Reemplazo de fusibles de la casa o reajuste del sistema de circuitos Fallo debido a la corrosi n en modelos que no est n protegidos contra la corrosi n Da o al product...

Page 27: ...s con dificultades auditivas favor de llamar al 800 TDD GEAC 800 833 4322 Piezas y accesorios GEAppliances com Aquellos individuos con la calificaci n necesaria para reparar sus propios electrodom sti...

Page 28: ...ite 310 1 Factory Lane Moncton N B E1C 9M3 Parts and Accessories In the U S A GEAppliances com Individuals qualified to service their own appliances can have parts or accessories sent directly to thei...

Reviews: