background image

2

IMPORTANT SAFETY INFORMATION.

READ ALL INSTRUCTIONS BEFORE USING

.

WARNING!

For your safety, the information in this manual must be followed to minimize the risk of fire, electric shock 
or personal injury.

„

 Use this appliance only for its intended 

purpose as described in this Owner’s 

Manual. 

„

 This air conditioner must be properly 

installed in accordance with the Installation 

Instructions before it is used. 

„

Never unplug your air conditioner by pulling 

on the power cord. Always grip plug firmly 

and pull straight out from the receptacle. 

„

Replace immediately all electric service  

cords that have become frayed or otherwise 

damaged. A damaged power supply cord 

must be replaced with a new power supply 

cord obtained from the manufacturer and 

not repaired. Do not use a cord that shows 

cracks or abrasion damage along its length 

or at either the plug or connector end. 

„

 Turn the unit OFF and unplug your air 

conditioner before cleaning

„

 GE does not support any servicing of the 

air conditioner. We strongly recommend 

that you do not attempt to service the air 

conditioner yourself.

„

For your safety…do not store or use 

combustible materials, gasoline or other 

flammable vapors or liquids in the vicinity  

of this or any other appliance.

„

 All air conditioners contain refrigerants, 

which under federal law must be removed 

prior to product disposal. If you are getting 

rid of an old product with refrigerants, check 

with the company handling disposal about 

what to do.

„

If the receptacle does not match the plug, 

the receptacle must be changed out by a 

qualified electrician.

„

 

These R410A air conditioning systems 

require contractors and technicians to  

use tools, equipment and safety standards 

approved for use with this refrigerant.  

DO NOT use equipment certified for  

R22 refrigerant only.

SAFETY PRECAUTIONS

Do not, under any circumstances, cut or remove 

the third (ground) prong from the power cord.  

For personal safety, this appliance must be 

properly grounded.
  DO NOT use an adapter plug with this 

appliance.
The power cord of this appliance is equipped 

with a 3-prong (grounding) plug which mates 

with a standard 3-prong (grounding) wall outlet 

to minimize the possibility of electric shock 

hazard from this appliance.
Power cord includes a current interrupter device. 

A test and reset button is provided on the plug 

case. The device should be tested on a periodic 

basis by first pressing the TEST button and 

then the RESET button while plugged into the 

outlet. If the TEST button does not trip or if the 

RESET button will not stay engaged, discontinue 

use of the air conditioner and contact a qualified 

service technician.

Have the wall outlet and circuit checked by  

a qualified electrician to make sure the outlet  

is properly grounded.
Where a 2-prong wall outlet is encountered,  

it is your personal responsibility and obligation to 

have it replaced with a properly grounded  

3-prong wall outlet.
The air conditioner should always be plugged 

into its own individual electrical outlet which has 

a voltage rating that matches the rating plate.
This provides the best performance and also 

prevents overloading house wiring circuits which 

could cause a fire hazard from overheated wires.
See the Installation Instructions, Electrical 

Requirements section for specific electrical 

connection requirements

HOW TO CONNECT ELECTRICITY

Summary of Contents for AEZ12 Series

Page 1: ...Cover Warranty 14 49 7657 2 10 13 GE AEW10 AEZ10 AEW12 AEZ12 Owner s Manual and Installation Instructions Write the model and serial numbers here Model _________________________ Serial ______________...

Page 2: ...ctrician These R410A air conditioning systems require contractors and technicians to use tools equipment and safety standards approved for use with this refrigerant DO NOT use equipment certified for...

Page 3: ...INSTRUCTIONS RISK OF FIRE Could cause serious injury or death DO NOT use an extension cord with this Window Air Conditioner DO NOT use surge protectors or multi outlet adaptors with this Window Air Co...

Page 4: ...ill turn on while setting Fan Speed Pads Use to set the fan speed to Low Med High or Auto on the unit NOTE On the remote control use the fan speed Increase Decrease pads to set the fan speeds to Low M...

Page 5: ...ddle set temperature Energy Saver Mode Controls the fan ON 7KH IDQ ZLOO F FOH RQ DQG RII ZLWK WKH compressor This results in wider variations of room temperature and humidity Normally used when the ro...

Page 6: ...iding it back into position NOTES Use 2 AAA 1 5 volt alkaline batteries Do not use rechargeable batteries Remove the batteries from the remote control if the system is not going to be used for a long...

Page 7: ...plug minimizes the possibility of electric shock hazard If the wall outlet you plan to use is only a 2 prong outlet it is your responsibility to have it replaced with a properly grounded 3 prong wall...

Page 8: ...ation Instructions Right accordion panel Foam top window gasket Left accordion panel Screw 6 Window sash seal Air conditioner Window locking bracket 1 PARTS INCLUDED Appearance may vary Frame locking...

Page 9: ...els if needed to fit in a narrow window See the window opening dimensions t All supporting parts must be secured to firm wood masonry or metal t The electrical outlet must be within reach of the power...

Page 10: ...ly constructed windows attach the window locking bracket to the window side jamb with one screw B C Wood Vinyl 3 Screws C 10 INSTALL THE AIR CONDITIONER IN THE WINDOW Place the air conditioner on the...

Page 11: ...NH VXUH WKHUH DUH QR FXUWDLQV EOLQGV RU IXUQLWXUH not cool as it should blocking the front of the air conditioner The temp control may 2Q PRGHOV ZLWK WRXFK SDGV Q WKH Cool mode press the not be set co...

Page 12: ...12 Notes...

Page 13: ...Notes GEAppliances com...

Page 14: ...KY 40225 Properly pack your unit We recommend using the original carton and packing materials Return the product to the retail location where it was purchased Include in the package a copy of the sale...

Page 15: ...strucciones de instalaci n 21 24 Solucionar problemas 25 Sonidos de operaci n normales 25 Servicio al consumidor Garant a 26 Servicio al consumidor 27 15 Escriba los n meros de modelo y serie aqu de M...

Page 16: ...azar el recept culo Estos sistemas de acondicionadores de aire R410A requieren que los contratistas y t cnicos usen herramientas equipos y est ndares de seguridad aprobados para su uso con este refrig...

Page 17: ...onar lesiones graves o la muerte NO use un prolongador con este Acondicionador de Aire de Ventana NO use protectores contra picos de tensi n ni adaptadores para m ltiples tomacorrientes con este Acond...

Page 18: ...de aire est encendido puede ajustarse para que se apague autom ticamente dentro de 1 a 24 horas C mo realizar el ajuste Pulse la tecla Delay 1 24hr Retardo 1 24h en la unidad o Delay pad Retardo del c...

Page 19: ...nly Solo ventilador Energy Saver Mode Modo de ahorro de energ a Controla el ventilador ON ENCENDIDO O YHQWLODGRU KDUi XQ FLFOR de encendido y apagado con el compresor Este resulta en variaciones mayor...

Page 20: ...tes de colocarlo otra vez en su lugar No lave el filtro en un lavavajillas PRECAUCI N NO OPERE el acondicionador de aire sin el filtro debido a que la suciedad y las pelusas lo obstruir n y reducir n...

Page 21: ...te acondicionador de aire Los cables caseros de aluminio podr an presentar problemas especiales Consulte a un t cnico electricista calificado ANTES DE INICIAR Lea estas instrucciones completa y cuidad...

Page 22: ...ivel Tijeras o cuchilla Un destornillador con hoja plana Panel de acorde n derecho Empaque superior de espuma de la ventana Panel de acorde n izquierdo Tornillo 6 Sello del marco de la ventana Acondic...

Page 23: ...del marco de la ventana GRUESO Para determinar el grueso coloque un pedazo de madera en el umbral para hacerla 1 2 m s alta que la parte superior del marco de la ventana de tormentas o del marco vinil...

Page 24: ...el soporte para bloqueo de ventana a el marco de la ventana con uno tornillo para prevenir da o a la ventana y vidro quebrado B C Madera Vinilo INSTALE EL ACONDICIONADOR DE AIRE EN LA VENTANA Coloque...

Page 25: ...ando tCerci rese de que los registros de la calefacci n no est n abiertos y se encuentran retornando el aire fr o Las bobinas de enfriamiento tVer Acondicionador de aire congel ndose m s adelante se c...

Page 26: ...tenimiento razonable y necesario Reemplazo de fusibles de la casa o reajuste del sistema de circuitos Fallo debido a la corrosi n en modelos que no est n protegidos contra la corrosi n Da o al product...

Page 27: ...s con dificultades auditivas favor de llamar al 800 TDD GEAC 800 833 4322 Piezas y accesorios GEAppliances com Aquellos individuos con la calificaci n necesaria para reparar sus propios electrodom sti...

Page 28: ...ite 310 1 Factory Lane Moncton N B E1C 9M3 Parts and Accessories In the U S A GEAppliances com Individuals qualified to service their own appliances can have parts or accessories sent directly to thei...