background image

„

 

You may hear a pinging noise caused by 

water being picked up and thrown against the 

condenser on rainy days or when the humidity  

is high. This design feature helps remove 

moisture and improve efficiency.

„

You may hear the thermostat click when the 

compressor cycles on and off.

„

Water will collect in the base pan during 

high humidity or on rainy days. The water 

may overflow and drip from the outdoor side 

of the unit.

„

 

The fan may run even when the compressor  

does not.

Normal Operating Sounds

 

Troubleshooting Tips.

 GEAppliances.com

Problem 

Possible Causes 

What To Do

Air conditioner 

The air conditioner

‡0DNHVXUHWKHDLUFRQGLWLRQHUSOXJLVSXVKHG

 

does not start 

is unplugged. 

  completely into the outlet.

 

The fuse is blown/circuit

‡&KHFNWKHKRXVHIXVHFLUFXLWEUHDNHUER[DQGUHSODFH

 

 

breaker is tripped. 

  the fuse or reset the breaker.

 

Power failure.

‡7KHXQLWZLOODXWRPDWLFDOO\UHVWDUWLQWKHVHWWLQJVODVW

 

 

 

  used after the power is restored.

‡7KHUHLVDSURWHFWLYHWLPHGHOD\DSSUR[LPDWHO\

 

 

  3 minutes) to prevent tripping of the compressor  

 

 

 

  overload. For this reason, the unit may not start  

 

 

 

  normal cooling for 3 minutes after it is turned    

 

  

back 

on.

 

The current interrupter

‡3UHVVWKH

RESET button located on the power cord plug.

 

device is tripped.

‡,IWKH

RESET button will not stay engaged, discontinue  

 

 

  use of the air conditioner and contact a qualified  

  

 

service 

technician.

Air conditioner does 

Airflow is restricted.

‡0DNHVXUHWKHUHDUHQRFXUWDLQVEOLQGVRUIXUQLWXUH

 

not cool as it should 

 

  blocking the front of the air conditioner.

 

The temp control may

‡2QPRGHOVZLWKWRXFKSDGV,QWKH

 Cool mode, press the 

 

not be set correctly. 

  Decrease 

ź

 pad.

‡2QPRGHOVZLWKFRQWURONQREVWXUQWKHWHPSHUDWXUH

 

 

 

  knob to a higher number.

 

The air filter is dirty.

‡&OHDQWKHILOWHUDWOHDVWHYHU\GD\V

 

 

 

  See the Care and Cleaning section.

 

The room may have been hot.

‡:KHQWKHDLUFRQGLWLRQHULVILUVWWXUQHGRQ\RXQHHG

 

 

 

  to allow time for the room to cool down.

 

Cold air is escaping.

‡&KHFNIRURSHQIXUQDFHUHJLVWHUVDQGFROGDLUUHWXUQV

 

Cooling coils have iced up.

‡6HH

“Air conditioner freezing up” below.

Air conditioner 

Ice blocks the air flow

‡2QPRGHOVZLWKFRQWURONQREVVHWWKHPRGHFRQWURODW

freezing up 

and stops the air conditioner 

  High Fan or High Cool with the Temp at or 2.

 

from cooling the room.

‡2QPRGHOVZLWKWRXFKSDGVVHWWKHFRQWUROVDW

High Fan    

  

 

or 

High Cool and set the thermostat to a higher    

 

  

 

temperature.

The remote control   

The batteries are inserted

‡&KHFNWKHSRVLWLRQRIWKHEDWWHULHV7KH\VKRXOGEH

 

is not working 

incorrectly. 

  inserted in the opposite (+) and (–) direction.

 

The batteries may be dead.

‡5HSODFHWKHEDWWHULHV

Water drips outside 

Hot, humid weather. 

‡7KLVLVQRUPDO

Water drips indoors 

The air conditioner is not

‡)RUSURSHUZDWHUGLVSRVDOPDNHVXUHWKHDLUFRQGLWLRQHU

 

 

tilted to the outside. 

  slants slightly from the case front to the rear.

Water collects in  

Moisture removed from air

‡7KLVLVQRUPDOIRUDVKRUWSHULRGLQDUHDVZLWKOLWWOH

 

base pan 

and drains into base pan. 

  humidity; normal for a longer period in very humid areas.

11

Summary of Contents for AEZ12 Series

Page 1: ...Cover Warranty 14 49 7657 2 10 13 GE AEW10 AEZ10 AEW12 AEZ12 Owner s Manual and Installation Instructions Write the model and serial numbers here Model _________________________ Serial ______________...

Page 2: ...ctrician These R410A air conditioning systems require contractors and technicians to use tools equipment and safety standards approved for use with this refrigerant DO NOT use equipment certified for...

Page 3: ...INSTRUCTIONS RISK OF FIRE Could cause serious injury or death DO NOT use an extension cord with this Window Air Conditioner DO NOT use surge protectors or multi outlet adaptors with this Window Air Co...

Page 4: ...ill turn on while setting Fan Speed Pads Use to set the fan speed to Low Med High or Auto on the unit NOTE On the remote control use the fan speed Increase Decrease pads to set the fan speeds to Low M...

Page 5: ...ddle set temperature Energy Saver Mode Controls the fan ON 7KH IDQ ZLOO F FOH RQ DQG RII ZLWK WKH compressor This results in wider variations of room temperature and humidity Normally used when the ro...

Page 6: ...iding it back into position NOTES Use 2 AAA 1 5 volt alkaline batteries Do not use rechargeable batteries Remove the batteries from the remote control if the system is not going to be used for a long...

Page 7: ...plug minimizes the possibility of electric shock hazard If the wall outlet you plan to use is only a 2 prong outlet it is your responsibility to have it replaced with a properly grounded 3 prong wall...

Page 8: ...ation Instructions Right accordion panel Foam top window gasket Left accordion panel Screw 6 Window sash seal Air conditioner Window locking bracket 1 PARTS INCLUDED Appearance may vary Frame locking...

Page 9: ...els if needed to fit in a narrow window See the window opening dimensions t All supporting parts must be secured to firm wood masonry or metal t The electrical outlet must be within reach of the power...

Page 10: ...ly constructed windows attach the window locking bracket to the window side jamb with one screw B C Wood Vinyl 3 Screws C 10 INSTALL THE AIR CONDITIONER IN THE WINDOW Place the air conditioner on the...

Page 11: ...NH VXUH WKHUH DUH QR FXUWDLQV EOLQGV RU IXUQLWXUH not cool as it should blocking the front of the air conditioner The temp control may 2Q PRGHOV ZLWK WRXFK SDGV Q WKH Cool mode press the not be set co...

Page 12: ...12 Notes...

Page 13: ...Notes GEAppliances com...

Page 14: ...KY 40225 Properly pack your unit We recommend using the original carton and packing materials Return the product to the retail location where it was purchased Include in the package a copy of the sale...

Page 15: ...strucciones de instalaci n 21 24 Solucionar problemas 25 Sonidos de operaci n normales 25 Servicio al consumidor Garant a 26 Servicio al consumidor 27 15 Escriba los n meros de modelo y serie aqu de M...

Page 16: ...azar el recept culo Estos sistemas de acondicionadores de aire R410A requieren que los contratistas y t cnicos usen herramientas equipos y est ndares de seguridad aprobados para su uso con este refrig...

Page 17: ...onar lesiones graves o la muerte NO use un prolongador con este Acondicionador de Aire de Ventana NO use protectores contra picos de tensi n ni adaptadores para m ltiples tomacorrientes con este Acond...

Page 18: ...de aire est encendido puede ajustarse para que se apague autom ticamente dentro de 1 a 24 horas C mo realizar el ajuste Pulse la tecla Delay 1 24hr Retardo 1 24h en la unidad o Delay pad Retardo del c...

Page 19: ...nly Solo ventilador Energy Saver Mode Modo de ahorro de energ a Controla el ventilador ON ENCENDIDO O YHQWLODGRU KDUi XQ FLFOR de encendido y apagado con el compresor Este resulta en variaciones mayor...

Page 20: ...tes de colocarlo otra vez en su lugar No lave el filtro en un lavavajillas PRECAUCI N NO OPERE el acondicionador de aire sin el filtro debido a que la suciedad y las pelusas lo obstruir n y reducir n...

Page 21: ...te acondicionador de aire Los cables caseros de aluminio podr an presentar problemas especiales Consulte a un t cnico electricista calificado ANTES DE INICIAR Lea estas instrucciones completa y cuidad...

Page 22: ...ivel Tijeras o cuchilla Un destornillador con hoja plana Panel de acorde n derecho Empaque superior de espuma de la ventana Panel de acorde n izquierdo Tornillo 6 Sello del marco de la ventana Acondic...

Page 23: ...del marco de la ventana GRUESO Para determinar el grueso coloque un pedazo de madera en el umbral para hacerla 1 2 m s alta que la parte superior del marco de la ventana de tormentas o del marco vinil...

Page 24: ...el soporte para bloqueo de ventana a el marco de la ventana con uno tornillo para prevenir da o a la ventana y vidro quebrado B C Madera Vinilo INSTALE EL ACONDICIONADOR DE AIRE EN LA VENTANA Coloque...

Page 25: ...ando tCerci rese de que los registros de la calefacci n no est n abiertos y se encuentran retornando el aire fr o Las bobinas de enfriamiento tVer Acondicionador de aire congel ndose m s adelante se c...

Page 26: ...tenimiento razonable y necesario Reemplazo de fusibles de la casa o reajuste del sistema de circuitos Fallo debido a la corrosi n en modelos que no est n protegidos contra la corrosi n Da o al product...

Page 27: ...s con dificultades auditivas favor de llamar al 800 TDD GEAC 800 833 4322 Piezas y accesorios GEAppliances com Aquellos individuos con la calificaci n necesaria para reparar sus propios electrodom sti...

Page 28: ...ite 310 1 Factory Lane Moncton N B E1C 9M3 Parts and Accessories In the U S A GEAppliances com Individuals qualified to service their own appliances can have parts or accessories sent directly to thei...

Reviews: