NOTES FOR INSTALLATION
Remove
Before removing air conditioner to the other place, you should contactthe
seller firstly.
Then it must be done under the direction of the professional technician. In
addition, the charge of this must be paid.
Noise
•
Install in a location where is firm enough to avoid the enlargement of
noise and vibration.
•
Don't put anything in front of the outlet of outdoor unit to avoid
increasing noise.
•
Be sure that hot air or noise will not inconvenience neighbors.
•
Please contact the seller as soon as there is strange noise during
operation.
•
Please use the safety support.
Electric wiring
•
Must connect with ground reliably.
•
The exclusive circuit must be used. But removable socket can't be used
because poor contact of it can cause over heat or fire.
•
Don't pull the power cord strongly.
•
In fixed circuit, there must be electricity leakage protection switch and
leakage current is less than 30mA.
•
Connecting method between air conditioners and power cord and
interconnecting method of each individual element with one another
should accord with wiring diagram on the unit.
•
The air conditioner should be installed in accordance with national
wiring regulation.
•
An all-pole disconnection switch having a contact separation of at least
3mm in all poles should be connected in fixed wiring
•
Air switch (thermal-magnetic breaker) should be installed in the circuit
•
If the supply cord is damaged, it must be replaced by the manufacturer
or your dealer or a qualified person to avoid a hazard.
•
All
t
he e
le
ctrical work must be done according to the local wiring
regulations.