INSTALLATION

Installation precaution:

Window type conditioner is so valuable and the improper
installation of it will cause a lot of damage! Please associate the
professional technician to install the unit and don't install it by
yourself. Otherwise, we are not responsible for the damage like
this.

Location:

The condensation water must be drained away conveniently.

Install air conditioner unit far away from TV set or radio etc. to avoid disturbing video or voice.

In salt and coastal area or place where is near thermal springs and polluted by sulphurous gas, or other
special areas, please contact the seller before use.

Avoid a place where is possible for in flammable gas to leak out.

Avoid other heat sources or direct sun light.

Avoid a place where is easy for children to touch.

Don't use the unit in the immediate surrondings of a laundry, a bath, a shower or a swimming pool.

For window type air conditioner with remote control, install in a location where is strong electromagnetic
disturbance, you should contact the seller in advance to avoid the malfunction in use.

How to install:

Choose a location where there are no any obstacle surrounding the unit , and the plug is accessible.

Prepare the installation hole slightly bigger than unit size.

Choose the installation space according to the following diagram.

The distance of obstructions from window unit inside
should be upper 150mm. left 150mm, right 150mm
and back 500mm.

Summary of Contents for AEE07KP

Page 1: ...GE Window Type Air Conditioner AEV07KP AEV09KP AEV12KP AEV18KP AEV24KP AEE07KP AEE09KP AEE12KP AEE18KP AEE24KP Use Care Manual GE Appliances ...

Page 2: ......

Page 3: ...peration for Mechanical Model 9 Operation of Control Panel for Electronic Model 9 Operation of Remote Control for Electronic Model 10 Operation Tips 13 To get the full benefit from your new Window Type Air Conditioner please read this Use Care Manual carefully before operating the unit Thank you for choosing a GE Window Type Air Conditioner Please keep this manual for future consultation GE Window...

Page 4: ...used in residence shop hotel office library and laboratory and so on Cooling in summer In hot summer Air conditioner can cool down the room air by transferring heat out Dehumidifying in rainy or humid season Air conditioner can dehumidify and make the room air dry and comfortable Exchange fresh air Open storm door to keep the fresh air in the room Room temp Spring Summer Autumn Wind direction Wint...

Page 5: ...ll vibrate violently to damage the refrigerant system and easily cause the compressor and electric components not work Earth wire To ensure the reliable earthing please do not connect earth wire to the following places Water pipe The ground must be connected Special socket must be used Furthermore the socket and wiring must conform to the wiring regulations And the earthing method must be reliable...

Page 6: ...ntact the seller before use Avoid a place where is possible for in flammable gas to leak out Avoid other heat sources or direct sun light Avoid a place where is easy for children to touch Don t use the unit in the immediate surrondings of a laundry a bath a shower or a swimming pool For window type air conditioner with remote control install in a location where is strong electromagnetic disturbanc...

Page 7: ...the cabinet with sponge or foam Installation assistance Use iron support The installation hole should be strong enough to support the air conditioner If it cannot iron support has to be used outdoors Iron support should be fixed on the building Shown at right figure Use sunshade board Air conditioner should avoid anything to be dropped into it and avoid direct sunshine If there is no cover on it y...

Page 8: ...edure whichmay however cause a small loss of performance 1 Slide out the chassis from the cabinet 2 Remove the rubber plug from the body base plate 3 Install the drain pan to the corner of the cabinet with 2 screws 4 Connect the drain hose to the outlet on the drain pan bottom 5 Slide the chassis into its original place in the cabinet Note Drain pan and drain hose must be installed before using re...

Page 9: ...usive circuit must be used But removable socket can t be used because poor contact of it can cause over heat or fire Don t pull the power cord strongly In fixed circuit there must be electricity leakage protection switch and leakage current is less than 30mA Connecting method between air conditioners and power cord and interconnecting method of each individual element with one another should accor...

Page 10: ... Lever When the slider at the OPEN position the ventilation door opens to allow air smoke or odors to be expelled from the room When the slider at the CLOSE position the ventilation door is closed and the air will be circulated inside the room and conditioned Front grille Air inlet louver Cabinet Air filter behind the front intake grille Front intake grille Control Panel Power cord Panel outlook p...

Page 11: ...aporator fins and the thermostat control knob counter clockwise This will quickly defrost the evaporator fins so that mormal cooling can be resumed HIGH COOL TURBO COOL 3 Air Swing Switch Airflow direction adjustment Side to Side To obtain a fix airflow direction set the air swing switch to ON for the vanes to swing from side to side until the desired flow direction is reached then switch it to OF...

Page 12: ... out a beep if remote control turbo speed by remote controller NOTE Control panel is capable of displaying temperature in degrees Fahrenheit or degrees Celsius To convert from one to the other Press and hold the Up and Down buttons on Control panel together for 3 seconds OPERATION OF REMOTE CONTROL FOR ELECTRONIC MODEL Delay 0 5 24hr Delay timer Decrease Mode select Fan speed Decrease Temperature ...

Page 13: ...hr button on the unit or the Delay button on the remote control Use the Increase Decrease buttons on the unit or the Increase Decrease button on the remote control to set a new time if desired During preview of timer or timer setting press Delay 0 5 24hr button on the panel or Delay button on the remote controller to cancel the timer setting Remote Control To ensure proper operation aim the remote...

Page 14: ...For Normal Cooling Select the Cool mode and High or Turbo fan with a middle set temperature For Maximum Cooling Select the Cool mode and Turbo fan with a lower set temperature For Quieter Nighttime Cooling Select the Cool mode and Low fan with a middle set temperature Energy Saver Mode The fan will cycle on and off with the compressor This results in wider variations of room temperature and humidi...

Page 15: ...a uniform temperature in the room Air can t be discharged to the direction of air in Make sure that the doors and windows are tightly closed Avoid opening doors and windows as much as possible to keep air conditioning in the room Clean the air filter regularly Blockages in the air filter reduce dehumidifying effects Clean the air filter at least once every two weeks Ventilate the room occasionally...

Page 16: ...s T h i s c a u s e s l o w e r e d performance and irregular operation Do not insert sticks or other objects into these vents as it is dangerous to touch the electric components and the fan Select the most appropriate temperature Pay attention to adjust the temperature to suit the conditions Rooms occupied by infants the elderly or the sick should be kept at an appropriate temperature Do not use ...

Page 17: ...net If the cabinet is very dirty dip cloth into warm water below 40 C dry the cloth and then rub off the dirt Vacuum cleaner Air lock could result in bad efficiency 2 Vacuum the filter on the dusty side to remove light dust 3 Don t use gas benzene solvent wash chemical solvent etc for cleaning 4 Do not splash water directly into indoor unit in which t h e r e a r e microcomputer and circuit plate ...

Page 18: ...ing from air conditioner Air conditioner dose not operate for about 3minutes when restart Is air inlet or outlet locking Is there any other heat cool source in room Are air filters dirty very much Is indoor fan speed set at LOW Maybe the room is too hot cool when the unit is started At COOL mode operation sometimes there is foggy air flowing out of indoor unit this is because the room humid air ha...

Page 19: ...nything else please contact the service center of GE Indoor Side DB WB Outdoor Side DB WB Maximum Cooling 32 23 43 26 Minimum Cooling 21 15 Maximum Heating 27 24 18 Minimum Heating 20 5 6 Working temperature range 21 15 Care and Maintenance n e a n e c a M n d a n i t C r a e ...

Page 20: ...66129910152 ...

Reviews: