background image

7

ESL Wireless Smoke Detector

WARNING

Smoke detectors CANNOT provide warnings for fires resulting from explosions, smoking in bed or other furniture,
ignition of flammable liquids, vapors and gases, children playing with matches or lighters.

Limited Warranty

ESL is a brand of GE Interlogix. The manufacturer warrants this smoke detector (except batteries) to be  free from defects in
material and workmanship under conditions of normal use for a term of 3 years from the date of manufacture.

During the warranty period, if a GE Interlogix product or any of its components becomes defective, it will be repaired or
replaced without charge.

Out-of-warranty units will be repaired at the discretion of the manufacturer or, if not, a card will be forwarded to the customer
suggesting a replacement unit and the cost of that unit.

This warranty does not apply to units which have been subject to abuse, misuse, negligence or accident, or to which any
modifications, alterations or repairs have been made or attempted.

This warranty is extended only to the original purchaser of the smoke detector and may be enforced only by such person.
During the warranty period, if the detector or any warranted components thereof becomes defective, it will be replaced or
repaired without charge at the manufacturer’s discretion if returned in accordance with the following instructions:

Obtain a Return Authorization Number by calling 1-800-777-4841 or 1-800-777-1415, then carefully pack it in a well padded
and insulated carton and return, postal charges prepaid to:

Customer Service RMA#
GE Interlogix
2266 Second Street North
North St. Paul, MN 55109

A note should be included advising the nature of the malfunction. Care must be exercised in the proper packing of detectors
returned under this warranty as GE Interlogix will not be responsible for warranty repairs to equipment damaged because of
improper packing.

The above warranty is in lieu of all other express warranties, and implied warranties of merchantability and fitness for a
particular purpose are limited in duration for a period of THREE years from the date of manufacture. Under no circum-
stances shall manufacturer be liable to the purchaser or any other person for incidental or consequential damages of any
nature, including without limitation damages for personal injury or damages to property, and however occasioned, whether
alleged as resulting from breach of warranty by manufacturer, the negligence of manufacturer  or otherwise.
Manufacturer’s liability will in no event exceed the purchase price of the product. Some states do not allow limitations on
how long an implied warranty lasts, or the exclusion or limitation of incidental or consequential damages, so the above
limitations and exclusions may not apply to you. Unless a longer period is required by applicable law, any action against
manufacturer in connection with this smoke detector must be commenced within one year after the cause of action has
occurred.

No agent, employee or representative of the Manufacturer nor any other person is authorized to modify this warranty in any
respect. Repair or replacement as stated above is the exclusive remedy of the purchase hereunder. This warranty gives you
specific legal rights and you also have other rights which vary from state to state.

FCC Compliance

This device complies with Part 15 of the FCC rules.  Operation is subject to the following two conditions:  (1) this device
may not cause harmful interference, and (2) this device must accept any interference received, including interference that
may cause undesired operation.

FCC ID: B4Z-844-SMOKE

Summary of Contents for 60-992-900

Page 1: ...dingly If the batteries are not replaced within seven days the detector s built in sounder emits a short beep or chirp every 45 seconds The detector also includes self diagnostics automatically adjusting its sensitivity accordingly to reduce the number of detector cleanings When cleaning becomes necessary the detector has a field replaceable optical chamber General Guidelines Before mounting detec...

Page 2: ...talled as follows 1 In all sleeping rooms 2 Outside of each separate sleeping area in the immediate vicinity of the sleeping rooms 3 On each level of the dwelling unit including basement NFPA 72 11 5 4 1Existing Apartment Buildings Detection Where required by applicable laws codes or standards for the specified for specified occupancy approved single and multiple station smoke alarms shall be inst...

Page 3: ...er levels of the building Smoke detectors may not warn in time when fires are caused by smoking in bed explosions improper storage of flammables overloaded electrical circuits or other hazardous conditions Programming This section describes the basic steps for programming learning the detector into panel memory For complete programming instructions refer to the specific panel installation instruct...

Page 4: ...fic panel installation instructions 4 After testing all detectors exit from Sensor Test mode Smoke Test The smoke test verifies that the detector activates when detecting smoke that the transmitted signal is received by the receiver panel and that the panel reports the alarm to the central monitoring station The smoke test should be performed annually 1 Contact the central monitoring station to al...

Page 5: ...d dispose of them properly 4 Observing correct polarity insert two new 3V lithium batteries into the battery compartment and replace the cover 5 Reattach the detector to the mounting base 6 Test the system Sensitivity Test Use this test to check detector sensitivity 1 Press and hold the detector test button for two seconds then release it The detector transmits a test signal then performs a self t...

Page 6: ...and maintenance When installed and used properly it requires minimal maintenance The smoke detector should be tested weekly See Testing the Detector Sensitivity and Smoke Testing the Detector When a detector requires maintenance it extinguishes its LED and sends a signal to the control panel as described in the following table 7 Line the new field replaceable optical chamber up with the optical ba...

Page 7: ...sed in the proper packing of detectors returned under this warranty as GE Interlogix will not be responsible for warranty repairs to equipment damaged because of improper packing The above warranty is in lieu of all other express warranties and implied warranties of merchantability and fitness for a particular purpose are limited in duration for a period of THREE years from the date of manufacture...

Page 8: ...ignal output types smokealarm heatalarm tamper rate of rise alarm test low battery trouble supervisory Listing UL268 CSFM CE FCC For use with the following panels ITI Advent Commercial Fire 60 562 03 or 60 562 06 with software versions 1 62 and higher Product Ordering Patents 4 855 713 4 864 636 5 686 885 5 686 896 6 396 405 Model Description 60 992 900 ESL commercial wireless smoke detector two 3...

Reviews: