5-10
239 Motor Protection Relay
GE Multilin
5 MONITORING
5 MONITORING
5
•
SUPERVISOR PROGRAM VERSION: This identifies the firmware installed internally in the
Supervisor (power fail) processor of the 239. This does not affect the functionality of the 239.
b) IDENTIFICATION
Product identification information is contained in these messages.
•
ORDER CODE: The order code shows the configuration of the relay and will appear as shown
below depending upon the options installed.
•
MOD NUMBER: If unique features have been installed for special customer orders, the
02'
180%(5
will be used by factory personnel to identify the matching product records. If an exact
replacement model is required, the
0$,1352*5$09(56,21
,
02'180%(5
, and product order code
found on the label located on the back of the 239 should be specified with the order.
It is possible for the 239 to have more than one
02'180%(5
installed (maximum of 5). In this
case the message will display all the
02'180%(5
s separated by a comma (i.e. 501, 502, 503).
•
SERIAL NUMBER: Each 239 shipped from the factory has a unique serial number for identifica-
tion purposes. The serial number displayed in this message will match the serial number found
on the product label located on the back of the 239.
•
HARDWARE REVISION: This message identifies the internal hardware revision of the 239. The
first letter of the 239 serial number must match the hardware revision identified in this message.
•
DATE OF CALIBRATION: Each 239 is calibrated to exceed the specifications listed in Section
1.4: SPECIFICATIONS on page 1–7 using custom made test equipment. When all parameters
have been calibrated and tested for proper operation the unit is stamped with the calibration date
displayed in this message.
•
DATE OF MANUFACTURE: This is the date the 239 was final tested at GE Multilin.
‘239’
Í
no options have been installed, basic unit
‘239-RTD’
Í
RTDs option has been installed
‘239-AN’
Í
Analog Output option has been installed
‘239-RTD-AN’
Í
RTDs and Analog Output options have been installed
Summary of Contents for 239
Page 2: ......
Page 4: ......
Page 16: ...1 10 239 Motor Protection Relay GE Multilin 1 OVERVIEW 1 OVERVIEW 1 ...
Page 104: ...6 14 239 Motor Protection Relay GE Multilin 6 239PC SOFTWARE 6 239PC SOFTWARE 6 ...
Page 150: ...8 10 239 Motor Protection Relay GE Multilin 8 TESTING 8 TESTING 8 ...
Page 152: ...A 2 239 Motor Protection Relay GE Multilin A 1 239 WARRANTY APPENDIX A A ...
Page 157: ...GE Multilin 239 Motor Protection Relay NOTES ...