Chapter 4: Web-Based Management
GE-DS-82 and 82-PoE Ethernet Managed Switch User Manual
131
Misc Configuration
In this page, you can change the default configuration for the 802.1x standard:
Figure 91: 802.1x Misc Configuration interface
c
This page includes the following fields:
OBJECT DESCRIPTION
Quiet Period:
Used to define periods of time during which it will not attempt to
acquire a supplicant.
Default time is 60 seconds.
TX Period:
Set the period the port waits for retransmit next EAPOL PDU during an
authentication session.
Default value is 30 seconds.
Supplicant Timeout:
Set the period of time the switch waits for a supplicant response to an
EAP request.
Default value is 30 seconds.
Server Timeout:
Set the period of time the switch waits for a server response to an
authentication request.
Default value is 30 seconds.
Max Requests:
Set the number of authentication that must time-out before
authentication fails and the authentication session ends.
Default value is 2 times.
Reauth period:
Set the period of time which clients connected must be re-
authenticated.
Default value is 3600 seconds
.