13-344
8 SERIES PROTECTIVE RELAY PLATFORM – COMMUNICATIONS GUIDE
CHAPTER 13: MODBUS MEMORY MAP
90951
0xC706 Block Transfer
0
0xC6CD00
1
FC142
0
2
Y
90953
0xC708 Events
0
1
1
FC126
1
1
Y
90954
0xC709 Targets
0
2
1
FC101
1
1
Y
Transfer Function Incomer 2
90961
0xC710 Inc 2 BKR Connected
0
0xC6CD00
1
FC142
0
2
Y
90963
0xC712 Inc 2 BKR Select To Trip
0
0xC6CD00
1
FC142
0
2
Y
90965
0xC714 Delay Select To Trip
0
6000000
1
s
F13
0
2
Y
90967
0xC716 Inc 1 BKR Conn&Closed
0
0xC6CD00
1
FC142
0
2
Y
90969
0xC718 Tie-BKR Conn&Closed
0
0xC6CD00
1
FC142
0
2
Y
90971
0xC71A Tie-BKR Connected
0
0xC6CD00
1
FC142
0
2
Y
90973
0xC71C Inc 2 Transformer
Lockout
0
0xC6CD00
1
FC142
0
2
Y
90975
0xC71E Inc 2 Source Trip
0
0xC6CD00
1
FC142
0
2
Y
90977
0xC720 Timed UV On This Source 0
0xC6CD00
1
FC142
0
2
Y
90979
0xC722 Block Trip On Double Loss 0
1
1
FC126
0
1
Y
90980
0xC723 Inc 2 BKR Closed
0
0xC6CD00
1
FC142
0
2
Y
90982
0xC725 UV On Other Source
0
0xC6CD00
1
FC142
0
2
Y
90984
0xC727 Delay Other Source
0
6000000
1
s
F13
3000
2
Y
90986
0xC729 Inst UV On This Source
0
0xC6CD00
1
FC142
0
2
Y
90988
0xC72B Delay This Source
0
6000000
1
s
F13
1000
2
Y
90990
0xC72D Fault Current Pickup In 1 0
0xC6CD00
1
FC142
0
2
Y
90992
0xC72F Fault Current Pickup In 2 0
0xC6CD00
1
FC142
0
2
Y
90994
0xC731 Fault Current Pickup In 3 0
0xC6CD00
1
FC142
0
2
Y
90996
0xC733 Fault Current Pickup In 4 0
0xC6CD00
1
FC142
0
2
Y
90998
0xC735 Fault Current Pickup In 5 0
0xC6CD00
1
FC142
0
2
Y
91000
0xC737 Fault Current Pickup In 6 0
0xC6CD00
1
FC142
0
2
Y
91002
0xC739 Block Transfer
0
0xC6CD00
1
FC142
0
2
Y
91004
0xC73B Events
0
1
1
FC126
1
1
Y
91005
0xC73C Targets
0
2
1
FC101
1
1
Y
Transfer Function Bus Tie
91020
0xC74B Tie-BKR Connected
0
0xC6CD00
1
FC142
0
2
Y
91022
0xC74D Tie-BKR Select To Trip
0
0xC6CD00
1
FC142
0
2
Y
91024
0xC74F Delay Select To Trip
0
6000000
1
s
F13
0
2
Y
91026
0xC751 Inc 1 BKR Conn&Closed
0
0xC6CD00
1
FC142
0
2
Y
91028
0xC753 Inc 2 BKR Conn&Closed
0
0xC6CD00
1
FC142
0
2
Y
91030
0xC755 Tie-BKR Closed
0
0xC6CD00
1
FC142
0
2
Y
91032
0xC757 Close Tie-BKR from Inc 1 0
0xC6CD00
1
FC142
0
2
Y
91034
0xC759 Close Tie-BKR from Inc 2 0
0xC6CD00
1
FC142
0
2
Y
91037
0xC75C Block Transfer
0
0xC6CD00
1
FC142
0
2
Y
91039
0xC75E Events
0
1
1
FC126
1
1
Y
91040
0xC75F Targets
0
2
1
FC101
1
1
Y
AR1 Setup
91060
0xC773 Function
0
1
1
FC126
0
1
Y
91061
0xC774 Maximum Number Shots 1
4
1
F0
1
1
Y
91062
0xC775 Block/Cancel
0
0xC6CD00
1
FC142
0
2
Y
91064
0xC777 Manual Close
0
0xC6CD00
1
FC142
0
2
Y
Modbus
Address
Hex
Address
Description
Min
Max
Step Units
Format
Code
Factory
Default
Size in
Words
8
5
0
8
6
9
8
8
9
8
4
5