background image

LED Refigerated Display Lights – Cleaning Instructions

• The outer lens and the plastic housing should be cleaned 

periodically with a mild liquid dish detergent.  

• Do not use chemical cleaners to clean the lens.

• Keep the outside clean. Wipe with a clean cloth lightly 

dampened with mild liquid dish detergent. Dry with a clean, 
soft cloth. 

• Do not wipe the lens with a soiled dish cloth or wet towel. 

These may leave a residue that can damage the finish. 

• Do not use scouring pads, powdered cleaners, bleach or 

cleaners containing bleach because these products can 
scratch and damage the finish.

11776-R110813

9

Risk of electrical shock. 

Plastic cover is needed to protect electrical wires from tampering and accidental contact. / 

Risque de choc électrique.

Le couvercle en plastique est requis pour assurer une protection adéquate contre l'accès aux fils et les contacts accidentels.

CAUTION / ATTENTION

7

Risk of electrical shock.

Disconnect power to LED Lights before any cleaning operation.

Risque de choc électrique. 

Débranchez l'alimentation des éclairages à LED avant toute opération de nettoyage. 

WARNING / AVERTISSMENT

Attach Covers to End Cap

• Tuck wires underneath Wire Cover before installing it onto

the End Cap.

• Attach Wire Cover to LED Light End Cap by inserting a

M2.9x10 pan head tapping screw (provided) through the 
holes in Covers and Mounting Tabs using an installation 
torque 0.32 N-m (3 lbf-in)

NOTE: 

Tighten slowly until fully seated, do not over tighten 

or strip the threads.

Wire
Cover

End Cap

M2.9x10 pan
head tapping
screw 

8

   

      GE Lighting Solutions  •  1-888-MY-GE-LED  •  www.gelighting.com

1 - 8  8 8 - 6  9 - 4 3 - 5 3 3

GE Lighting Solutions, LLC is a subsidiary of the General Electric Company. Immersion is a trademark of GE Lighting Solutions, LLC. The GE brand and logo are trademarks of the General Electric Company.
© 2013 GE Lighting Solutions, LLC. Information provided is subject to change without notice.  All values are design or typical values when measured under laboratory conditions.

This product is intended solely for the use of commercial refrigerated, display or case lighting and is not intended for use in
any other application.

Summary of Contents for IMMERSION RV40 Series

Page 1: ...rload driver follow installation instructions for the GEPS4000NCMUL SY Ensure that all connection points are sealed for damp location using the appropriate method per the NEC or local electrical code LED DRIVER COMPATIBILITY This system is compatible with the GEPS4000NCMUL SY LED Driver Please refer to the separate LED driver installation guide for appropriate wiring connections FOR YOUR SAFETY Re...

Page 2: ...local regulations LED driver installation will begin at Step 7 and Step 8 To install the LED light first identify the wiring for connection to the LED driver After removing the connector from ballast leave the existing ballast input and output wires for reconnection in a later step Remove Existing Lighting Components 1 Tools Required Components Required LED light LED driver Wire cover M3 5x1 3x13 ...

Page 3: ...sh a dimple Use power drill and 2 8 mm 7 64 inches drill bit to drill holes at the intersection of the vertical center line and the horizontal lines Prepare for Installation of Center LED Lights 2 of mullion Total width 10 mm 3 8 For 750 mm 30 inch LED Lights 687 mm 27 1 32 Center punch at intersection and drill a 2 8 mm 7 64 hole mullion Half total width of LED Driver wires top For 900 mm 36 inch...

Page 4: ...ights per LED driver loading limit 2 End LED Lights is equivalent to 1 Center LED Light Risque de blessure Ne pas surcharger le driver LED 60 watts maximum par driver Dans le cas des lampes LED de 30 75 cm et de 36 90 cm ne pas dépasser 5 lampes LED centrales par limite de charge du driver 2 lampes LED latérales équivalent à 1 lampe LED centrale CAUTION ATTENTION LED DRIVER LED DRIVER Center LED L...

Page 5: ...EFT END LED LIGHT B R RIGHT END LED LIGHT D Occupancy Sensor Gray Purple Note LED Lights are polarity insensitive Note LED Lights are polarity insensitive TERMINAL BLOCK LED DRIVER WHITE NEUTRAL BLACK LINE SWITCH B R B W B R G CENTER LED LIGHT A C B D Occupancy Sensor Gray Purple TERMINAL BLOCK LED DRIVER WHITE NEUTRAL BLACK LINE SWITCH B R B R B W B R G CENTER LED LIGHT CENTER LED LIGHT A C B D O...

Page 6: ...he connector cavities are correctly populated per the wire cavity table on page 5 OPTION 2 USING TWIST ON WIRE CONNECTORS Remove the 4 way connector from the LED Driver by cutting the wires near the connector and strip the output leads Using the appropriate wiring diagram on page 5 connect the LED Driver output leads to the LED Light leads using wire connectors or other connection method approved ...

Page 7: ...ning operation Risque de choc électrique Débranchez l alimentation des éclairages à LED avant toute opération de nettoyage WARNING AVERTISSMENT Attach Covers to End Cap Tuck wires underneath Wire Cover before installing it onto the End Cap Attach Wire Cover to LED Light End Cap by inserting a M2 9x10 pan head tapping screw provided through the holes in Covers and Mounting Tabs using an installatio...

Reviews: