6
5
Connect LED Driver - Input
Connect LED Driver - Output
Connect Dimming Contacts – Output (Optional)
6
7
OPTION 1 – USING 3-WAY CONNECTOR
Attach the supplied green/yellow ground wire from the
LED Driver to a grounded metal portion of the door frame.
Connect the original Line and neutral wires (or Line 1 and
Line 2 wires for 240 nominal VAC) to the 3-way connector
for the LED Driver input wires using the appropriate
matingconnector (Molex P/N 39-01-4030). Ensure that
the connector cavities are correctly populated per the
wire cavity table on page 5.
OPTION 2 – USING TWIST-ON WIRE CONNECTOR
Attach the supplied green/yellow ground wire from the
LED Driver to a grounded metal portion of the door frame.
Remove the 3-way connector from the LED Driver by cutting
the wires near the connector and strip the input wires. Using
the appropriate wiring diagram on page 5, connect the
original Line and neutral wires (or Line 1 and Line 2 wires for
240 nominal VAC) to the LED Driver leads using twist lock wire
connectors or other connection method approved for low
temperature usage and stranded cable. Ensure that the
connector cavities are correctly populated per wire cavity
table on page 5.
• Make input (AC) connections using one of the two options below:
• The LED Driver is required to be reliably bonded to the protective ground conductor.
• Make output (DC) connections using one of the two options below:
OPTION 1 – USING 4-WAY CONNECTOR
Connect the LED Driver output leads to the LED Light leads
using the appropriate mating connector (Molex P/N 39-01-
4046). Terminals installed should be crimped using approved
tooling and process per Molex specifications. Ensure that the
connector cavities are correctly populated per the
wire cavity table on page 5.
OPTION 2 – USING TWIST-ON WIRE CONNECTORS
Remove the 4-way connector from the LED Driver by
cutting the wires near the connector and strip the output
leads. Using the appropriate wiring diagram on page 5,
connect the LED Driver output leads to the LED Light leads
using wire connectors or other connection method approved
for low temperature usage and stranded cable.
(A)
For non-dimming applications, cap the unused wires with
4mm (5/32") twist on wire connectors.
OPTION 1 – USING 4-WAY CONNECTOR
Connect the LED Driver dimming output leads to the
occupancy sensor or control system using the appropriate
mating connector (Molex P/N 39-01-4046). Terminals installed
should be crimped using approved tooling and process per
Molex specifications. Ensure that the connector cavities are
correctly populated per the wire cavity table on page 5.
(D)
OPTION 2 – USING TWIST-ON WIRE CONNECTORS
Remove the 4-way connector from the LED Driver by
cutting the wires near the connector and strip the output
leads. Using the appropriate wiring diagram on page 5,
connect the LED Driver dimming output leads to the
occupancy sensor or control system using wire connectors
or other connection method approved for low temperature
usage and stranded cable.
(D)
• To enable dimming operation, connect leads from occupancy sensor or control system (normally open contact) to the purple
and gray leads of the power supply.
• Make output (contact closure) connections using one of the two options below:
• The LED Driver is capable of step dimming from 100% power to 20% power when used with a normally open contact closure
occupancy sensor system.
•
When using the LED drivers for non-dimming applications,
the dip switch setting must be set to #1 ON to
disable the dimming feature and achieve 100% illumination.
A
A
C
D
B
C
D