1.

 

          

S

AFETY 

P

RECAUTIONS

 

     

                             

                                

 

 

WARNING!

 

 FAILURE TO FOLLOW THESE SAFETY PRECAUTIONS AND INSTALLATION INSTRUCTIONS COULD 

RESULT IN INJURY OR DEATH AND

/

OR DAMAGE TO PROPERTY AND EQUIPMENT

 

 

Appropriately licensed and competent personnel only should install the automation equipment. 

 

The operators are designed specifically to open and close sliding gates or doors and should not be used for any 
other purpose. 

 

Before commencing installation, read through this installation manual. 

 

Check that the operator and controls are in new condition and have not been damaged in transit. 

 

Check the gate or door and it’s associated support posts and walls to protect against shearing, compression and 
other various traps which could cause serious injury or death. Take into consideration the general installation and 
surrounding environment. 

 

Check the gateposts or mounting structure has the necessary strength and rigidity to support the operator and the 
load of the opening and closing gate motion.

 

 

CAUTION!    

          

          

          

          

          

          

   

Always incorporate the appropriate Photo Electric Cells, Induction Loops and any other 
safety devices to protect both equipment and personnel. Extra caution should be employed 
when using operator in auto close mode.

 

 

 

 

Display any necessary signs to indicate any danger areas and automatic operation of the gate or door. 

 

The operators are not designed to be used in any hazardous areas or areas subject to flooding etc. 

 

All electrical connections and wiring must be performed with AS/NZS 3000-2007 as the guidelines. (Or its 
counterpart for other countries outside of Australia and New Zealand)  

 

WARNING! ELECTRICITY CAN KILL 

 

 

The manufacturer of the automation equipment is not responsible for the damage which may be caused to either 
the operator, gate or door and any other person or equipment when: - 

o

 

Wrong or poor installation practices were performed. 

o

 

No or inadequate safety devices were used. 

o

 

E

ITHER THE SURROUNDING STRUCTURE OR THE GATE OR DOOR STRENGTH AND RIGIDITY WAS NOT 

SUFFICIENT FOR THE TASK IN HAND

o

 

I

NEFFICIENT LOCKING DEVICES WERE EMPLOYED

o

 

Poor maintenance on the equipment. 

o

 

Any other circumstances beyond the manufacturers control.

 

 

I

SOLATE POWER BEFORE ATTEMPTING ANY MAINTENANCE

,

 QUALIFIED PERSONNEL ONLY TO CARRY OUT 

MAINTENANCE

 

 

O

NLY ORIGINAL SPARE PARTS ARE TO BE USED SHOULD THERE BE A REQUIREMENT FOR THEM

.

 

 

 

K

EEP LOOSE CLOTHING AND HANDS CLEAR OF THE GATE WHILST IN OPERATION OR POTENTIALLY ABLE TO BE 

OPERATED

 

T

HE INSTALLER SHOULD PROVIDE ALL INFORMATION CONCERNING THE USE OF THE AUTOMATION EQUIPMENT AS 

WELL AS INSTRUCTIONS REGARDING THE MANUAL OVERRIDE AND MAINTENANCE PROCEDURES TO THE USERS OF 

THE SYSTEM

 

Summary of Contents for GDS DRIVE 500

Page 1: ...Installation and Maintenance Manual Domestic Sliding Gate Operator MODEL GDS DRIVE 500 A B N 62 059 806 405 Nov 2016 V1 00 ...

Page 2: ...ons 3 2 Wiring Requirements 4 3 Installation details 7 14 Operator Dimensions Mechanical Installation Mounting detail Control board layout Electrical Connections Programming Trouble shooting 4 Manual release 14 5 Maintenance details 15 6 Warranty 10 ...

Page 3: ...y necessary signs to indicate any danger areas and automatic operation of the gate or door The operators are not designed to be used in any hazardous areas or areas subject to flooding etc All electrical connections and wiring must be performed with AS NZS 3000 2007 as the guidelines Or its counterpart for other countries outside of Australia and New Zealand WARNING ELECTRICITY CAN KILL The manufa...

Page 4: ...removing the 240vac transformer and following wiring set up for solar connection The power supply transformer can be removed and installed in an IP rated enclosure and mounted away from the gate operator This is done sometimes where mains power is not available or it is impractical to run mains power to the site The operator can be supplied with a separate power supply upon special order Then all ...

Page 5: ...nting plate to concrete pad using 10mm x 100mm dynabolts 7 If the anti tamper bar is to be used follow the steps below 8 Or position the operator base plate back in positon and bolt down to the concrete Now you can positon the operator in the best position to suit the gate rack by starting at one end loosely hold a piece of rack on top of the pinion and gently against the gate rail then slide the ...

Page 6: ...6 Guide to fitting anti tamper bracket ...

Page 7: ...actuators 1 The operator has been set up at the factory to close to the left when looking from the inside of gate looking out so firstly if you re gate closes to the right swap over the white and brown wires on the lc and lo or Limit close and Limit open limit connection plugs Also you will need to swap over the blue and black motor wires ...

Page 8: ...or approx 20mm forward from this position this will then give you a more accurate final position for the bracket to allow for run on of the gate Make sure you drill between the valleys of the rack and mount using the supplied 5mm stainless bolts shown above Do the same for the open limit actuator Once the operator is running you can slide the actuator across to fine tune the final stopping positio...

Page 9: ...9 Control Board Layout Programming ...

Page 10: ...10 ...

Page 11: ...11 ...

Page 12: ...12 ...

Page 13: ...13 ...

Page 14: ...14 ...

Page 15: ... the door out to release for manual operation To lock the gate back into automatic operation move the gate to around the half way positon push the lever back in then lock off in position with the key The first operation will be a slow close so it re learns its positioning Normal operation will resume ...

Page 16: ... good condition Gate stops are installed and in good condition not loose Gate rack is tight correct clearances between pinion wheel rack Gate track is not damaged Gate operator mounting bolts tight No oil leaks from gearboxes Inside operator and control box clean Baygon Surface Spray around operator not on electronics All electrical connections tight Check battery charge voltage correct Unplug mai...

Page 17: ...ING CIRCUMSTANCES i IF NO PROOF OF DATE OF PURCHASE CAN BE PRODUCED ii IF THE PRODUCT HAS BEEN USED IN A MANNER BEYOND ITS DESIGN PARAMETERS iii IF THE PRODUCT IS TAMPERED WITH OR REPAIRED BY PERSONNEL NOT AUTHORISED TO DO SO iv IN RESPECT OF LOSS OR DAMAGE CAUSED BY ROUGH TREATMENT v IF THE PRODUCT IS NOT USED AND MAINTAINED IN ACCORDANCE WITH INSTRUCTIONS OR RECOMMENDATIONS LISTED IN THIS INSTAL...

Reviews: