GDC Group Brazilia F 5 Installation And Owner'S Manual Download Page 3

Installer Guide

3

Installer guide

3 - 17

1.0 Introduction

4 - 5

2.0 Technical Data

6 - 7

3.0 Site Requirements

8 - 10

4.0 Installation

11

5.0 Commissioning the Appliance

12

6.0 Annual Servicing

13

7.0 Changing Components

14 - 17

8.0 Fault Finding

18

9.0 Short Parts List

19

Owner guide

20- 27

1.0 Warnings

21

1.1 Safe Installation

21

1.2 In case of gas leaks

21

1.3 Guarding

21

1.4 Servicing your Appliance

21

2.0 Introduction & Operation

22

2.1 Introduction

22

2.2 Operating units that are not fitted

with the Comfortstat control

22

2.3 Operating units fitted with the

Comfortstat control

23

3.0 Cleaning & Clearances

24

3.1 Cleaning the Appliance

24

3.2 Clearances

24

4.0 Spares & Running costs

25

4.1 Spare Parts

25

4.2 Running Costs

25

5.0 Troubleshooting

26

6.0 Warranty & Service

27-28

7.0 Warning

27

Section

Page(s)

Contents

Installer

Before continuing any further with the

installation of this appliance please read the

following guide to manual handling:

The lifting weight of this appliance is as below:

Model

Gross weight (kg)

F 5 

18.0.

F 5S 

19.1.

F 8S & F 8ST

24.4.

One person should be sufficient to lift the fire. If

for any reason this weight is considered too

heavy then obtain assistance.

When lifting always keep your back straight.

Bend your legs and not your back.

Avoid twisting at the waist. It is better to

reposition your feet.

Avoid upper body/top heavy bending. Do not

lean forward or sideways whilst handling the

fire.

Always grip with the palm of the hand. Do not

use the tips of fingers for support.

Always keep the fire as close to the body as

possible. This will minimise the cantilever

action.

Use gloves to provide additional grip.

Always use assistance if required.

Summary of Contents for Brazilia F 5

Page 1: ...omfortstat 2 F 8ST Balanced Flue Gas Wall Heaters Installation and Owner Guide Please leave these instructions with the user 5131922 06 Brazilia F 5 Brazilia F 5S Brazilia F 8ST Comfortstat 2 Brazilia...

Page 2: ...m or database or transmitted in any form or by any means whether electronic mechanical recording or otherwise without the prior written permission of the copyright owner Applications for the copyright...

Page 3: ...roubleshooting 26 6 0 Warranty Service 27 28 7 0 Warning 27 Section Page s Contents Installer Before continuing any further with the installation of this appliance please read the following guide to m...

Page 4: ...d flue arrangement Except for Comfortstat the appliance is controlled by a control knob which operates the ignition and alters the heat output The control knob has five positions giving a choice of th...

Page 5: ...ons Failure to install the appliance correctly could lead to prosecution GAS SAFE REGISTER and CORGI require their members to work to recognised standards In the United Kingdom the installation must a...

Page 6: ...ols Rotary thermostat allowing Comfortstat a lowt position and adjustment between low and high temperature settings Flame failure device Thermocouple Output 8 13mv Heat Exchanger Cast Iron 2 0 Technic...

Page 7: ...device Thermocouple Output 8 13mv Heat Exchanger Cast Iron 2 0 Technical Data F 5 F 5S Propane When converted using kit No 5110284 Category of Appliance II2H3P The appliance is set for Gas Type G31 at...

Page 8: ...de for Gas Installations in Timber Framed Dwellings 3 2 Clearances 1 The appliance must be fitted on a vertical flat non combustible wall Any combustible wall coverings should be removed from within t...

Page 9: ...capable of being opened or any ventilation inlet or similar opening no part of the terminal shall be within 300mm 1 ft measured vertically from the bottom of the opening b Where the flue terminal of...

Page 10: ...ntended for use in habitable rooms and must not be fitted in cupboards or confined compartments 3 6 Gas Supply 1 The inlet connection is located on the gas tap at the bottom right hand side of the app...

Page 11: ...20mm 3 4in Adjust the distance from the back of the airbox and the joint between the terminal and air duct to this dimension Using the length of flue tape provided fix this dimension by taping up the...

Page 12: ...ide are completed 1 Push in and turn the control knob back to the OFF position 2 On models not fitted with the Comfortstat control remove the knob from the appliance by gently pulling the knob forward...

Page 13: ...xchanger casting If necessary clean the viewing window 14 With a light brush carefully remove deposits from the spark electrode burner flame ports and the burner gauze Fig 17 15 Replace the rope seal...

Page 14: ...studs 2 Remove the three screws holding the burner retaining plate to the airbox and undo the thermocouple nut from the gas tap Fig 23 25 3 Ease the thermocouple and electrode leads from the rubber g...

Page 15: ...ry aeration hole Fig 27 8 Reassemble in reverse order of dismantling 7 5 Injector 1 Remove the burner as described in sections 7 4 1 to 7 4 4 2 Undo the injector and sealing washer retaining the washe...

Page 16: ...d undo the thermocouple nut from the gas tap Fig 31 33 3 Ease the thermocouple and electrode leads from the rubber grommet Fig 32 4 Disengage the burner from the injector and pull the electrode lead o...

Page 17: ...to the burner inlet ensuring that it covers the primary aeration hole Fig 35 8 Reassemble in reverse order of dismantling 8 4 Injector 1 Remove the burner as described in sections 8 3 1 to 8 3 4 2 Und...

Page 18: ...18 8 0 Fault Finding 3 5 0 5mm 7 1 5mm Fig 38 Ensure all installation criteria have been satisfied before performing Fault Finding e g flue terminal position Installer Guide...

Page 19: ...enerator 042941 I 381941 Injector F 5 F 5S 224047 J 381942 Injector F 8S F 8ST 224104 K 205791 Washer For injector 082365 L 205844 Insulation F 5 F 5S 224048 M E01359 Insulation F 8S F 8ST 223971 N 15...

Page 20: ...Owner Guide Brazilia F 5 Brazilia F 5S Brazilia F 8ST Comfortstat 2 Brazilia F 8S...

Page 21: ...covering adjacent to any heating appliance The likelihood of wall staining from convected air currents will be increased in environments where high levels of tobacco smoke or other contaminants exist...

Page 22: ...gas to enter the burner ready for ignition Keep the knob pushed in for 20 seconds and the burner should remain alight If not repeat the sequence NOTE Under extreme wind conditions more than one attem...

Page 23: ...gnition Keep the knob pushed in for 10 seconds and the burner should remain alight If not repeat the sequence NOTE Under extreme wind conditions more than one attempt to light the appliance may be req...

Page 24: ...lish 3 2 Clearances 1 Internally the appliance must not be fitted under a shelf or sill that projects more than 150mm 6in 2 Curtains or a shelf must not be closer to the top of the outer case than 140...

Page 25: ...ed for customers suffering from arthritis or similar conditions and provides the user with extra leverage when operating the control knob It is available from Spares Stockists 4 2 Running Costs 1 The...

Page 26: ...ol knob not fully pushed in for sufficient period of time Keep the control knob pushed in for 20 secs and the burner should remain alight If not repeat the sequence Cold Start Up of Appliance Extreme...

Page 27: ...ave the following information to hand 1 Fire serial number and fascia code Located on the information label See figure 4 on page 27 2 Date of installation 3 Your installer name and address details 4 F...

Page 28: ...staller Details Block Capitals Installer Name Gas Safe Register or Corgi Registration Number Company Name Company Address Company Telephone number Company Fax number Owner Guide Information label loca...